Electric generators.
Hydro generator.
Electric meter.
Electric generators.
Access control power supply, CCTV power supply, SMPS, Power adapter, POE and so on power supply ..
Generator, canopy, amf panel, battery, gel earthing (2 x 80, 3 x 80).D.G. Set repairing ,services, AMC, installation, gel earthing
Uninterruptible power supply (ups) system: ranging from 500va - 640kva online/offline and line - interactive ups.IT solution
Co2 laser power supply, laser tube, yag, UPS, Xenon lamp power.
SMPS, power supplies.
Balance charger, high power touch screen charger, monitor, power meter, cell meter-7, cable for charger.
10-600 KVA online UPS uninterrupted power supply components.
GBCDG11AF006SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF006SACH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1 - 0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF006SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF006SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 792 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF008SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF008SACH Relay type CDG 11 Special Case size 1D V 10T Application O/C Current setting 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 771 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF009SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF009SACH Relay type CDG 11 Special Case size 1D V 10T Application E/F Current setting 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 793 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
GBCDG11AF011SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF011SA(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 - 10 Amps. Name Plate RFG9125674 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
- engine: gasoline / diesel - capability: 2kw-30kw - package: HANTU brand, OEM, or neutral packing -certificate: CE, GS, UL, approval -
40k lead acid battery, copper aluminium battery.
Power adapter / transformer.
400kv Power Transformer, Electric Transformers, Power Transformer.