DAQGPCT485 split core current transformer is a kind of current sensor transformer which can convert AC analog signal into RS485 digital signal launched by Shanghai Data Acquisition IOT Technology Co LTD The product has builtin 32bit ARM series MCU and highprecision metering chip and is a multipoint calibrated current conversion module It has the characteristics of high precision and fast response DAQGPCT485 can directly interact with common data acquisition gateways DTU programmable controller PLC and host computer
This product is widely used in AC motor lighting equipment air compressor heating ventilation and air conditioning equipment building selfcontrol system equipment OEE open rate industrial Internet rural power transformation projects and other scenarios of current monitoring and acquisition scenarios
2 Service Concept
Our company solemnly promise you
You buy more than just products but also meticulous and thoughtful technical support
We provide free remote guidance remote configuration and commissioning services and send data to the server specified by the customer
Free IOT solution consulting services
3 Product Characteristic Parameters
Line Sequence Definition
Red12V BlackGND Yellow485A White485B
Length of LineDefault 1 meter
Acquisition Characteristic
Current detection range AC 02A100AOther large range transformers can be customized
Electrical Characteristic
Power supply mode524V DC
Operating power consumption05W
Operating frequency5060Hz
Communication Characteristic
Transmission modeRS485
Communication protocol Modbus RTU
Structural Characteristic
MaterialABS plastic housing
Installation methodBuckle mounting
Working Environment
Temperature 20C70C
Storage Environment
Temperature 20C80C
4 The Core Advantages of the Product
High precision measuring chip high measurement accuracy
Open type design easy to install
Easy installation and fast deployment helping IOT projects land quickly
5 Description of the Modbus Communication Protocol
51 Serial Port Communication Parameters
Baud rate9600 Data bit8 Verify NONE Stop bit1
52 Function Code Definition
The upper computer uses 03 function code to read data or receive alarm data
The host computer controls the lower machine equipment transformer using 06 function code
Features
.High initial permeability and high AL value
.High effective insertion loss and excellent noise suppression
.Wide frequency range,large adjustable range for permeability from 20000-160000
.Low core loss, small choke size for volume and wieght with epoxy coating
Application:
.Switched-mode Power supplies
.EMI common mode filter
Features:
DC current immunity composite cores is combined with amorphous and nanocrystalline cores together
Magnetic features:
. Strong anti-DC-capacity
. Precision, the scope of application of 0.5-0.1 grade and applicable Current range 1.5-200A
. Good temperature stability
Applications:
.DC current immunity transformers
.Metering transformer in electronic power system
Features:
The adjustable range of permeability
Excellent frequency characteristics
High saturation magnetic induction strength
Lower eddy current losses
Excellent temperature stability
Applications:
Switching Mode Power Supply
UPS Uninterrupted power supply
Pulse welding equipment
Power converter
Strange dc current immunity applicable current range (1.5a-200a)
High linearity, high accuracy class, applicable transformer accuracy range 0.5-0.1 class
Good temperature stability
Core size saving by volume and weight
Applications:
.DC current immunity transformers in electronic energy meter/watt-hour meter
.Metering transformer in electronic power system
21998 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600V
Output signal (AC current) 500mA,1A,2A,5A AC at nominal input current
Output signal (AC voltage) 333mV, 500mV, 1V, 5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output (2.5m)
Mechanical parameters
Dimensions (L x W x H)(mm) 180 x 319 x 35
Weight (g) 1100
Holding wire diameter (mm) 125
Max. jaw opening (mm) 125
Color Black
Material PC+ABS+Polycarbonate, UL94 V0
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600 V
Output signal (AC current) 500mA,1A,5A AC at nominal input current
Output signal (AC voltage) 333mV,500mV,1V,5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 116 x 327 x 35
Weight (g) 1200
Holding wire diameter (mm) 120 x 50
Max. jaw opening (mm) 50
Jaw Color White
Material PC+ABS+Polycarbonate, UL94 V0
FEATURES
Most cost-effective
Faster installation
Safe and easy installations
High accuracy 0.5
Holding wire diameter: �?16mm
Measurement range of 1mA to 200A AC
Low phase shift for power measurement
Output model: Lead output(2.5m)
Isolated plastic case recognized according to UL94-V0
Small-size, compact size, light-weight
Over-Voltage protection circuit is installed.
CE, UL / EN 61010 - 1 certified
PARAMETERS
Technical parameters
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 1000: 1 or 2000:1 , customized
Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%
System Voltage 720V(0.72kV)
Output signal 10mA-200mA AC optional
333mV AC or 100mV-2V optional
Frequency range 40 Hz-500 Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Output Standard 2.5 meter cable
Protection Level 3.0V0-P
Installation Category CAT or CAT 600VAC
Max. jaw opening 16 mm
Mechanical parameters
Dimensions (WDH) (mm) 38mm 55mm 18mm
Weight(g) 60
Operating conditions
Operating temperature -25C to +55C
Relative Humidity 0-85% non-condensing
Altitude
FEATURES
Most cost-effective
Faster installation
Safe and easy installations
High accuracy 0.5
Holding wire diameter: 32mm
Ratio ranging from 60/1A to 600/5A
CE, UL
PARAMETERS
Technical parameters
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 400: 5 or 200:5 , customized
Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%/60Hz
System Voltage 720V(0.72kV)
Output signal 1A or 5A
333mV AC or 100mV-2V optional
Burden 2.5VA
Frequency range 40 Hz-500 Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Output Standard 2.5 meter cable
Max. jaw opening 32 mm
Mechanical parameters
Dimensions (DH) (mm) 110mm130mm 41mm
Weight(g) 700
Operating conditions
Operating temperature -25 C to +55 C
Relative Humidity 0-85% non-condensing
Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Accuracy Class 0.5%, 1%
Range of primary rated current 300-3000A
Range of Rated load 25VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS)
Technical parameters
Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class 0.5S, 0.5%, 1%, 3%
Range of primary rated current 100-1000A
Range of Rated load 10VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 150%I1n
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS)
GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids.