DESCRIPTION Hexcell single-phase PLC meter based on digital media information exchange medium, it features include active measurement, high precision clock, load switch control, moreover can also reading data from the PLC, the near infrared, RS485 and set parameters FUNCTIONS 1.Rmeasure active power forward and reverse respectively, measuring the total active power (forward and reverse) 2.Event log including: power, open front cover, open terminal cover, reverse, magnetic field, the unbalanced load, over voltage, low voltage, programming records, time corrected record and remote pull switch, etc. 3.Tariffs: 4 tariffs, Monday to Sunday 7 ordinary day time, 16 holiday period, 16 special holiday time, can be divided into eight period one day. 4.Contains hours freezing (24 hours), froze1.n (62 days) and freeze power in previous 12 months 5.Remote switching function 6.Load profile: load profile for 30 minuters, frozen data (time + live wire power + null wire power load profile)
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Customized meter design for Finland Utility. 2.Special terminal block connection for easy wiring. 3.Terminal cover &front cover with detecting features. 4.With backup battery for RTC. 5.Load Profile(Optional) 6.MD measurement 7.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 8.With optical communication port(IEC1107) 9.Open protocol: DLMS/COSEM(Optional)
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. With infrared, RS485, PLC and GPRS communication equipped, DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Functional LCD displays(menu driven, scrolling function, IR remote control mode) 2.Events record: Power-on/power-off (latest ten time), power quality monitoring(10 times), meter cover open(10 times recorded and can be read by MDM software). 3.Load curve recording: Active/reactive energy, voltage(3 phases), current(3 phases), power factor(3 phases) and time stamp(DD/MM/HH/YY) 4.External relay 5.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 6.RTC, broadcast time synchronization via communication interface(could be set by GPS time via the MDM) 7.Optional multi-communication: PLC based on OFDM according to CENELEC standards(A-band), GPRS(SIMCOM-chip), RS485, integrated M-Bus(extended connection to gas and water meters) according to OMS standard. 8.Open Protocol: DLMS/COSEM 9.Advanced AMI integration (Optional)
DESCRIPTION The DDS1088 single phase two wire electronic meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges.DDS1088provides metering solution benefiting both consumers and power utilities. It complies with theapplicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES High Accuracy measurement with cyclometric register display, 5 digits. Wide operating voltage range 0.8Un ~ 1.15Un. Long time precisely works without calibration and limit error linear maintains flat during heavy loading from start to end. With active impulse LED indicator and reverse energy LED indicator With cover of terminal block made by transparent material. Measures active energy and reverse always add to positive. Meter Base and Cover ultrasonic Sealed
Description The ddsy1088 single phase keypad energy meter measures total active energy.It is STS certified. and complies with the standards of IEC62052-11, IEC62053-21, IEC62055-41 &IEC62056-21.BS standard complied. It can be inserted the plug-in communication module to achive the AMR/AMI solution.And with built-in relay,it can be remote control. Function 1.Easily configurable Prepaid & Postpaid mode by token 2. Anti-tamper 3. Load profile 4. Exchangeable, optional communication module:GPRS/3/4G/PLC/GSM/Ethernet 5.Real time measures voltage, current, frequency, active power, etc 6.Open Protocol: DLMS/COSEM 7.Programable multi-tarrif
Place of Origin: Henan, China Brand Name: AFT Model Number: AFTLD Type: Variable Area Water Flowmeters Accuracy: 0.2% 0.5% Liner: PTFE , Rubber,F46,PFA Connection: Flange,Clamping, thread, clamps Output: 4-20mA /RS485/HART/PROFIBUS DP Medium: milk beer drink water Protection grade: IP65 / IP 68(optional) Ambient temperature: -25~ +150â?? Power supply: 220VAC/ 24VDC Material: carbon steel Product Name: Digital modbus chemical magnetic flow meter for sewage
CP-C moving coil panel meter with sprung toe bearing which is insensitive to external magnetic fields. The movable organs of the movements are stored in sprung jewels in order to protect them against crushes and vibrations. These instruments only measure DC current or DC voltage. By using core magnets of high quality the moving coil instruments have a almost linear scale course. Due to their low consumption they are especially suited for the application with shunts, impulse transmitters, thermo couples and for the connection to our electronic transducers. The instruments can be delivered for direct connection up to 100 A with a built-in shunt. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
CA-212 has been designed to ensure high accuracy in power factor regulation and excellent utilization of capacitor banks and relays in three phase 3 wire electrical grid common range for all network voltages from 100V to 440V system reactive power compensation front panel is equipped with a 3-digits 7 segments display to show the present value of power factor voltage and line current. Max 12 steps relay output for contactor easy commissioning optional LCD display screen(provide power monitor function and CT ratio setting). FEATURES I / U / COS measurement Three digital LED display Max 12 control steps (default 6 steps) Used in three-phase balance gird Self-powered from bus line
CB-212 is advance three phase 3 wire APFC display provide user-friendly interface and ease of access to parameters for manual setting built-in power analyzer allowing the instantaneous display of any electrical parameter (voltage current reactive power harmonics etc. With THD protection function not affected by the harmonics can protect capacitor from harmonic interference. Max 12 step control 5A/250V relay output or 12VDC output. Optional RS-485 communication port easy for user connect to PLC and build SCADA system. Higher measurement accuracy(0.5) and system stability it is cost effective ideal for OEMs and panel builders solution. FEATURES I / U / KW / KVAR / HZ / COS measurement and display 93*70 LCD display Anti-harmonic design Max 12 steps capacitor control
CD-212 is ready for operation with its preset functions immediately after installation without any modifications or adjustments. With smart switching control identifies the power of the connected capacitor stages and connects or disconnects them in an optimized manner as required by the actual mains conditions. This guarantees that optimum power factor correction is achieved with the minimum number of switching operations. Dynamic compensation response time less than20ms work with static contactor provide zero-crossing switching and harmonic protect function Suitable for welding steel rolling machinery cranes oil field pumping units wind power generation piling machines and other varies equipment with large instant impact system. With RS485 communication port can control extra 3 sets CD-212 build Max 48 step control. FEATURES Automatic detect electrical network system status, do not need special configuration Large size TFT LCD display, one screen can show more info than segment LCD screen Various automatic protection functions can make sure capacitor bank long term working With basic electrical parameter measurement and display (I / U / KW / KVAR / KVA / HZ / COS) Provide power quality statu display (Current & Voltage wavefrom and 2-31th Harmonic) Record past 4 days site Power factor trend, display in visualization graph
CP-PF series meter using on single phase or 3- phase system measure cos Ï?i, has a moving coil meter movement that shows by an electronic circuit the phase shift between voltage and current (cos. Ï?). Scales are available between 90° and 360° phase shift, as well as capacitive and inductive. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
CP-W and CP-var analog power meter consists of a moving coil meter with installed transducers which measures the active / reactive power in a sinusoildal or not sinusoidal current circuit and which transformes it into an analogue signal. This is then passed to the moving coil movement. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements MODELS Ordering info Measurement range (Include CT/VT ratio) Overload (Amp/voltage reading) Accuracy class Operation frequency Marine use or not
KLY meters are direct acting analog electrical measuring instruments. They are mainly used on the distribution, control panel of power plant and other different apparatus to measure current, voltage, frequency, power, power factor, synchroscopes. Phase sequence and other non-electric values The digital meters measure and display the current, voltage, frequency, power, power factor in electric power network and automation control system Operating Temperature KLY Series:-25C~+55C CP Series:-20C~+40C Storage Temperature -40C~+70C
CP-PF series meter using on single phase or 3- phase system measure cos Ï?i, has a moving coil meter movement that shows by an electronic circuit the phase shift between voltage and current (cos. Ï?). Scales are available between 90° and 360° phase shift, as well as capacitive and inductive. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
DCEM energy meter is an advanced solution for multi-channel DC system. It can visually display voltage, current, power data and energy cumulative data. With a panel keypad, it can set voltage display parameters and the DC shunt parameters. With RS485 communication interface, DCEM can be connected to the monitoring center. It is a high-performance automatic meter suitable for UPS system detect, Solar energy plant monitor, industrial and mining enterprises, civil construction, building automation etc. Features ·External Hall sensors for isolation current input, higher safety security ·Max 4 channels energy detect & display. ·Multi-use LCD screen for volt / amp / energy data. ·Built-in isolation circuitry can measure the maximum 1KV voltage signal. ·Provide 4 channels DI port, 2 channel DO for control. ·Provide RS485 port for remote communication.
New 194J series Smart Power Manager is the more powerful meter than 194Y series power analyzer. With higher precision and more measurement parameters. This meter is the latest series meter developed in 2015 by Blue Jay tech. It is the ideal choice for monitoring and controlling of power distribution systems. Application ·Provide remote fire alarm. ·Temperature data reading. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs. Features ·Class 0.2 power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RS-485 Modbus/RTU Communications ·Measured varies of power parameter. (Max demand/unbanlance/crest factor/K factor...) ·Optional 2 channel Digital Input (DI) and 3 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·Provide max 50 lists SOE record function ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC)
Three phase electrical network power quality detection device, provide energy consumption and generate; THD (Total Harmonic Distortion); Harmonic individual data reading. Build-in 4 tariffs energy logger function, with onboard memory can record last three month energy data, free to set max 12 segment record period, can be use as a commercial billing unit. Application ·Applied to the control of general switch boards and low, medium and high voltage connection points. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs. Features ·Class 0.5S power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RJ45 Ethernet port support Modbus-TCP Communications ·With 2 channel Pulse Output (PO) for active energy&reactive energy counting ·Optional 1 channel Analog Output (AO) ·Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC)
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Title goes here. ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RJ45 Ethernet MODBUS-TCP Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes
Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. It is designed for high level performance and are safe and fast to install. Blue Jay have a complete range of DIN-mounted electricity meters for different applications, together with a wide range of communication options. The meters are quick and easy to install due to their DIN-rail mounting. It is highly accurate, durable, reliable, lower power consumptive, without reversion, creep proof, anti-tanmpering and bilateral recoring with strong overloading capability. It conforms to the related Chinese requirement of GB/T17215.321-2008 and International requirement IEC62053-21 also pass EMC and LVD. Real-time measurement: voltage, current, power, power factor, frequency, Time-of-use metering of forward and reverse active energy, four-quadrant reactive energy; Maximum 4 tariffs; with 1 active pulse output; Automatic settlement function (with a storage of 12 months history records); Optional Event logging function (power on, power down, zero clearing, demand clearing, programming, timing events); Optional 2 channels switching value inputs, 1 electromagnetic relay outputs; Optional 1 channel 12V, 50 mA DC power supply output; Voltage and current ratio range: 0.0000~9999.9999; Abundant programmable alarm outputs; RS-485 supporting Modbus RTU protocol and DL/T645 protocol, self-adaptive; Indication prompts for voltage broken phase, inverse phase sequence, communication and other status; Configurable cyclic display items; Completely enclosed design, dust proof and antifogging. Interface electrical performance: Optocoupler relay output interface: AC/DC 250V,100mA Switching value input interface: Conductor Resistance 1.2KΩ Transmitter output interface
The 19D-301 three-phase DIN-rail energy meter is an intelligent device for medium and low voltage systems (6-35KV and 0.4KV). It integrates data collection and control functions, provide LCD display show three-phase AC power measurement and calculation, consumption energy value. In addition, 19D-301 also provide optional function, user can choose multi-tariff record, Maximum Demand record, relay alarm output(1 channel) for different site condition. RS485 port support MODBUS-RTU or DL/T645-2007 protocol (can be customized). features: 1.- Central display area: mainly displays measurement data. Energy, current, voltage, power, power factor, frequency, timer (depends one different sub-model, display value may parts of above parameter). 2.- Four LED indicators: Show meter condition (accept customized). 3.- Four keys button: for user set operation.