[ CHARACTERISTICS ] Accurate heat consumed under heat load is measureable * Display of various information : Heating energy / cooling energy Instantaneous heat and accumulated quantity, temperature , instantaneous flow rate, accumulated flow rate, etc. â?¢ Easy data transfer function through MODBUS RS 485 [ SPECIFICATIONS ] * Display - DC Type : Touch Screen Color Graphic LCD - AC Type : 2 X 20 Characteristic LCD with El Backlight or VFD * Temperature - Operating temperature: 0 ~ 60 â??â?? - Storage temperature: 25 ~ 70 * Power : 85 ~ 264 V AC / 12 V DC * Case dimension : (W) 150 mm X (H) 180 mm X (D) 50 mm * Input - Frequency Range: 0 Hz to 5 kHz / K factor Range: 0.0001 to 50,000.000 (Pulse / Units) - RTD Signal Type: Open Collector, Voltage or Current Pulse * Output - Analog Function: 4 ~ 20 mA calorific output / accuracy: 0.1% - Pulse Output #1 (Energy Total) Output: Open Collector transistor will sink 50 mA max - Pulse Output #2 (Flow Total) Pulse width: 5 ms , 10 ms , 100 ms , 200 ms * Communication - Kinds RS 485 MODBUS - Baud Rate 1200 ~ 19,200 BPS - ID code 4 Multi Point communication, specific address programmable * Display unit - Energy kWh, J , cal , BTU - Volume m3, L * Data logging - Logging interval : Day, hour and second can be set - Logging information : Volume Total, Volume Rate, Energy Total, Energy Rate, Temperature, Date & Time - Internal memory 12 months (Logging interval: 1 minute storage, 1 year storage) For more details on quality Korean flowmeters, please feel free to visit
[ CHARACTERISTICS ] Various inputs such as flow meters and pressure gauges. Real time communication through Modbus, BlueTooth , etc. 2G Data logging â?¢ Convert MODBUS or RS232 input to HART Item [ SPECIFICATIONS ] * Display 3.5 inch (320 x 240) Touch Screen Color Graphic LCD * Power : 90 ~ 240 V AC (Free Volt) * Output : RS 232 ASC DATA, HART Communication, RS485 MODBUS, 4~20 mA Output(24bit) of Flow Rate, MODBUS TCP/IP Ethernet(LAN), BlueTooth Wireless, 2 GB Memory, Memory Data Download USB Memory, Total Pulse Output(TTL), DC 24 V Power (0.6 A) * Input : RS 232 ASC DATA, HART Communication RS 485 MODBUS Communication 4 ~ 20 mA * Protection class : IP 65 * Piping pressure input 24 V DC pressure gauge drive and display * Size : (W) 150 mm X (H) 180 mm X (D) 50 mm
Product Features: Online measurement of AC current below 60kV (operate with insulated rod above 600V). Features 1. The unique U-shaped opening structure realizes unobstructed measurement, which is particularly convenient for on-site measurement. 2. Suitable for high current test, range: 0.00A~9999A 3. It adopts wireless transmission mode, and the transmission distance is 100m. Data retention function, data storage function.
The 149-10A is a digital voltmeter that can measure high voltages up to a10kV AC and DC at high accuracy. Its high input impedance (1000M ohm) make it suitable for measurement of high impedance voltage circuits. Since it has a high accuracy despite its small size and light weight, it can also be easily used as a portable calibrator.
This electrical energy meter (kWh) phase DIN rail is a new generation of single-phase electronic energy meters, using techniques microelectronic circuits high integration (LSI), digital techniques and advanced techniques CMS. The meter meets the technical requirements of class 1, class 2 and IEC62052-11, IEC62053-21. It is used to measure active energy consumption accurately and directly from the ac phase (50/60 Hz).
M-4673 mini digital leakage current clamp meter features high reliability, safety, precision and compact design with 1mA resolution. AC/DC Current range of 100A; particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is T-RMS. Whole range overload protection, reliable measurement accuracy and unique design makes it an outstanding new generation electrician/electric power measurement instrument.
Clamp on AC current measurement up to 200 A. The CMP-200 digital clamp meter is designed for clamp measurements of AC leakage current. Clamp on AC Current CMP-200 Features high resolution (0,1 mA), three measuring ranges: 200 mA, 2 A, 200 A. display LCD 3�½ digit (max 1999), white LED backlight, sinternal diameter clamp approx. 30 mm (1,2â?³), DATA HOLD function, for holding measured values. MAX function, AUTO-OFF function, double molded casing. Available on back-order
Name:Manual Bottle Cap Torque Sensor Application/Usage:Manual torque tester to measure open force and closure force of the caps of bottles. Capacity:100 Kgf.cm for Approximate Cap Diameter: 30-180 mm Handling Time: 7-10 Days Brand Name:Monad Brand Name: BT-55 Item Description:It is 100% Stainless steel construction, including Torque Sensors, clamping mechanism, body and fasteners. Product Specialization: During the life cycle of a screw closure, there are a number of factors where the performance of the closure is influenced by a particular torque value: Filling / Sealing Storage & distribution first opening Use, reseal and re-use In addition to torque generally associated with screw closures (eg application and removal torque), closure development areas such as tamper-evident seals, or child resistance have increased the range of torque which need to be measured. Note: This product price does not include any import duty/Custom Duty, buyer will be responsible for the same in their respective countries. We accept payment through PayPal Only. We will dispatch the product as per our handling time after the payment confirmation. Color Variation: colour may vary 5-10% In case of any query or dissatisfaction you can Contact us via Message before Purchase.
The Cellular Electricity Power IoT RTU is a powerful smart meter used for power internet of things solution, is special using for remote monitoring 100~400VAC of 3-Phase electricity power distribution safety and measurement, can measuring the 3-phase 3-wire, 3-phase 4-wire distribution power voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy. Also, it provides Dual SIM, 2 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity, also 1 RS485 for extend I/O to monitoring oil level and temperature or read meters. 1. Can be operated from anywhere, no distance limitation; 2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside. 3. 3G/4G/NB-IoT Modules are optional, LCD Display is optional; 4. Modular design, can easily upgrade the cellular module if network upgrade; 5. Embedded ARM�® Cortexâ?¢-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with anti-jamming and in-built watchdog; 6. High isolate voltage, current and voltage input signal isolated by accuracy transformer, afford arrive DC2500V; 7. Working Voltage: 60~500VAC or 70~800VDC; 8. 3-phase 3 wires or 4 wires power parameter measurement, include voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy, phase loss; 9. Measurement range: AC100~400VAC, currant range: 5A, other range should use CT; 10. 2 digital inputs, compatibles dry and wet contact, 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs; 11. 1 ambient sensor input for monitoring onsite temperature and humidity ; 12. 1 RS485 port, supports Modbus RTU Master and Slave, can be used to extend I/O ports or meters; 13. Provides 1 channel DC power source output for external device, saving wiring cost; 14. Each parameter can setup threshold, when exceed or recovery will alarm immediately; 15. Can monitoring phase loss, when occurs will alarm immediately. 16. Inbuilt inter-lock logic programmer and powerful timer program function. 17. Resend the data while communication failure and alert to users by SMS; 18. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications; 19. Supports Modbus TCP, Modbus RTU protocol and transparent transmission, can be used as master and slaves, can integrate to SCADA, HMI, DSC directly; 20. Supports USB setting, reading, records inquiry and firmware upgrade;
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
Product overview Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection. Technical parameters Category Performance, parameters Host Principle Ultrasonic time difference principle Accuracy ±1% Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French. Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms) Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC. Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined. Pipe inner diameter 15~6000mm Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter) Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves. Temperature -30�ºC~160�ºC Turbidity 10000ppm and small bubble content Flow rate 0~�±10m/s Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C Humidity Host:85%RH Sensor protection level IP67 Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time. Different measurement can be achieved by using the AC90~260V power adapter. Power consumption 1W Shell material Flame retardant ABS Host weight 390g
Product overview Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection. Technical parameters Category Performance, parameters Host Principle Ultrasonic time difference principle Accuracy ±1% Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French. Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms) Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC. Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined. Pipe inner diameter 15~6000mm Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter) Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves. Temperature -30C~160C Turbidity 10000ppm and small bubble content Flow rate 0~±10m/s Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C Humidity Host:85%RH Sensor protection level IP67 Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time. Different measurement can be achieved by using the AC90~260V power adapter. Power consumption 1W Shell material Flame retardant ABS Host weight 390g
PUTF201 clamp-on transit-time ultrasonic flow meter utilizes transit-time principle.The transducer is mounted outside surface of the pipe without requirements of flow stop or pipe cutting.It is very simple,convenient for installation,calibration and maintenance. Small,media,large three pairs of transducers meet different size pipeline measurement demand.Plus,select thermal energy measuring function to achieve completely energy analysis.Widely applied for processing monitoring water balance test district heating balance test energy efficiency monitoring as easy installation and simple operation advantages.
Product Profile NHG268 gloss meter is a high-end precise tri-angle smart gloss meter for surface glossiness measurement and management, which can be widely applied in all kinds of industries, such as plastics, metals, paint and coating, furniture, wood, ink, printing and packaging, cosmetics, fabrics, textiles and garments, electronics, tiles and decoration industry. In one word, NHG268 tri-angle gloss meter can be perfectly applied in any place that requires gloss measurement and control. Quick Details Place of Origin: Guangdong, China Brand Name: 3nh/ThreeNH Model Number: NHG268 Power: Electronic Product Category: Gloss Measuring Instrument Product Name: Gloss Meter Measurement Angle: 20�° + 60�° + 85�° Measurement Range: 0 - 2000GU Division Value: 0.1GU Measurement Mode: Basic, Statistical, Continuous Operation: by Screen-touch Data Port: USB PC Software: GQC6 Equivalent Model: BYK 4563
DTSY1088 single phase integrated type keypad meter measures total active energy. It is STS certified and complies with the standards of IEC62052, IEC62053, IEC62055, IEC62056 etc . The Measurement and Control Unit (MCU) is BS standard complied and can be installed into meter box to prevent unauthorized operation. FEATURES 1.Easily configurable Prepaid & Postpaid mode . 2.Reverse energy measured in forward. 3.Easily configurable user friendly kWh. 4.Configurable LCD displaying items 5.Programming reading by optical 6.Communications between MCU and MSDS is 4G/3G/GPRS (MCU to DCU is RF/PLC ) 7.Real time measures voltage, current, frequency, active power, etc. 8.Events record with time stamp. 9.Open Protocol: DLMS/COSEM 10.Plug&Play Communication modules(RF/PLC/4G/3G/GPRS optional ) 11.Advanced AMI/AMR integration
Standards 1, IEC62052-11:2003 2, IEC62053-21:2003 Features 1.Measurment: Measure total active energy and tariffs. 2.Meaure total active max demand and four tariffs total active max demand. 3.multi-tariff function. 4.Record previous 12 months data.
DESCRIPTION The DDSY1088 single phase two wire postpaid meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges.DDSY1088 provides metering solution benefiting both consumers and power utilities. It complies with the applicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES 1. High accuracy measurement with LCD display,5 integers. 2. Wide operating voltage range 0.8Un ~ 1.15Un. 3. Long time precisely works without calibration and limit error linear maintains flat during heavy loading from start to end. 4. With active impulse LED indicator and reverse energy LED indicator 5. With cover of terminal block made by transparent material. 6. Measures active energy,reactive energy and reverse always add to positive. 7. Meter base and cover ultrasonic sealed 8. The communication between meter and CIU is PLC
DESCRIPTION The single phase two wire electronic meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges. featured with source-load missing neutral anti-tamper function, and provides metering solution benefiting both consumers and power utilities. It complies with the applicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES 1. LCD display with backlight function even if power failure. 2.Wide operating voltage range0.7Un ~ 1.15Un, withstand 1 hour limit operating voltage up to 380V. 3.The meter can works under harsh environment conditions of kind of variations by high accuracy in a long time 4.without calibration, and its limit error linear maintains flat even during heavy loading status from start to end. 5.Useful infrared communication for meter reading and setting. 6.With active impulse LED indicator and impulse test output. Anti-Tamper function. 7.Measures voltage and current with LCD display. 8.Maximum demand.
DESCRIPTION Adopting large scale IC and SMT processes,the DTSD1088 DLMS meter is made to accurately total active/reactive energy,forward and reverse active/reative energy and maximum demand.And in real-time it also measures and takes in process parameters like active/reactive power,apparent power,Voltage,current,power factor,frequency and so on,and implements time-of-use control,automatic stroge of reading-day demand,and records load profile and events.And with infrared,RS485,PLC communications equipped,the DTSD1088 DLMS meter is an ideal device to realize time-of use energy measurement and efficient processing in ease.It complies with applicable standards of IEC62052-11,IEC62053-21,IEC62053-61,IEC62054-21,IEC62056-61,IEC62059-11,IEC62059-21. FEATURES 1. Energy measurement (separate and total):Forward and reverse,active,four-quadrant,time-of use,sub-phase. 2. Demand record 3. Real-time parameters 4. Data archive 5. Data freezing 6. Events record 7. Optional infrared,PLC,M-BUS,Ethernet,GPRS communication