Distribution boards, RCCB, MCB, MCCB etc. Of branded make, like ABB/HAGER/HPL. Made in india.
We are works a manufacturing electrical switchboard in indonesia and so we can install electrical switchboard that. We move on to in electrical & instrumentation installation for factory & industry. Move on as your order.
10" Krone&110 Dual IDC wall mountable cat6 patch panel Model: LY-PP6-10 *Specification: 1.12 port, Length:10" 2.Height:1U 3.High reliability and superior performance 4.Meet T568A/B standards. 5.With plastic mount, mounting to the wall. Screws included *Features: 1.Each port is 100% tested to ensure NEXT and return loss performance 2.individually serialized to support traceability; 3.Utilizes 110 punch down termination on back panel and includes retention cap for each port; 4.Each port contains a universal label that is color coded for T568A and T568B wiring schemes; 5.Terminates 4 pair, 22 - 26 AWG, 100 ohm, solid or stranded twisted pair cable; 6.Optionally mount to standard EIA 10" rack. Individual package:1pc into polybag, then into white /brown box. Export carton package: 10pcs/carton, G.W/N.W:14/13kgs,carton size:51.5*29*31.2cm.
Metal Clad Switchgears SETAS Metal Clad Switchgears are switching and control cubicles manufactured between 1 kV 40.5 kV comply with IEC 62271-200 standards. SMC series Metal Clad Switchgears are defined with following features according to IEC 62271-200 standards. 3mm sheet steels LSC 2B class Loss of Service Continuity Pm Partition Class AFLR Internal Arc Classification 4 earthed accessible compartments Maximum personnel safety with 31.5 kA/ 1 s internal arc test. Safety electrical and mechanical Interlocking systems. Withdrawable type Vacuum / SF6 Circuit Breaker for fast and easy servicing General Production Range and Specifications Rated Voltage : 3.640.5 kV Power Frequency withstand Voltage : 1085 kV Lightening Impulse withstand Voltage : 40185 kV Rated Frequency : 50/60 Hz Rated Current ( natural ventilation ) : 6303150 A Short Circuit withstand Current : 1631.5 kA ( 3 s ) Internal Arc withstand Current : 1631.5 kA ( 1 s ).
SME series Metal Enclosed Switchgears are defined with followwing features 2 mm sheet steel LSC 2A Loss of Service Continuity Pl Partition Class AFL Internal Arc Classification 3 earted accessible compartmments Maximum personel safety with up to 25 kA / 1s internal arc test Safety electrical and mechanical Interlocking systems SF6 gas insulated Circuit Breaker allows fast and easy servicing Grounding systems with ensured continuity. General Production Range and Specifications Rated Voltage : 3.640.5 kV Power Frequency withstand Voltage : 1085 kV Lighting Impulse withstand Voltage : 40185 kV Rated Frequency : 50 / 60 Hz Rated Current : 6301250 A Short time withstand current : 16/20/25 kA ( 1 sec ) Internal Arc withstand Current: 16/20/25 kA ( 1 sec ).
CRCA sheet3.15mm 1.50mtrx1.20mtrx0.50mtr depth Angle 40x40x5mm Incoming 01nos-440amp, 50ka, 4pole, 415v, 50hz Outgoing-02nos-160amp, 35ka, tppole, 415v, 50hz Outgoing-02nos-100amp, 35ka, tppole, 415v, 50hz. V-(0-500)analog A-(0-800)analog. 5% (in case of wooden packing), however stretch polygraph packing.
We build and install main distribution panel, sub-distribution panel, capacitor panel, lighting panel, and medium voltage panel as well.
Electrical control panels.
Motor Control Centre (MCC Panel) having: Incomer: 630A MCCB Cyclic Timers Star Delta Starters: 30 HP - 3 nos. 20 HP - 3 nos. DOL Starter 1-5 HP - 16 nos. MCCB for 50 HP ATS - 2 nos. Electrical Panel with: ACB 1250 A. - 2 nos. Changeover Switch 1250 A - 1 No. MCCB 630 A TP - 4 nos.
FRP junction box
MCB Box
Electric products 10 pcs
Main functions: 1. Decrease starting current. Utilizing soft start as the most general application starting mode, the motor is given an initial voltage setting, from the initial voltage level; the output voltage to the motor is steplessly increased to the rated full voltage in the pre-setting ramp time. The starting current of the motor is limited in 2 times of the rated working current, while the conventional full voltage starting current is 5 or 6 times of the rated working current. The limited soft starting current can decrease the insulation damage to the motor & the cable and avoid the problem of mechanical and electric pressure as well as lengthen mechanical life of the ESP-unit and reduce maintenance. 2. Eliminate operating over-voltage. Utilizing soft stop as the most general application stop mode, the output voltage to the motor is steplessly decreased from the full voltage to the point where the load torque is greater than the developed motor torque, this can eliminate the 3 or 4 times operating over-voltage occurred with conventional coast-to-rest stop or unexpected power-off. The destruction of the 3 or 4 times operating over-voltage is always a deathblow especially to the worn-out and low-insulating motor. 3. Surge voltage absorption equipment The built-in resistance-capacitance surge voltage absorption equipment can effectively reduce the destruction of the opposing electromotive force occurred with coast-to-rest stop or unexpected power-off, so as to protect the motor. 4. By-pass contactor If the Controller senses that the soft starter itself has a malfunction, the output voltage can be switched to full voltage (Power-Frequency) to ensure the continuous running by the built-in bypass contactor. 5. Auto-startup under load time delay When mechanical unit soft stop under load, if user turn on the auto-startup when under load, it will soft start automatically by the time delay setting. 6. Consummate protection It can protect the mechanical unit not only overload, under load, short circuit, phase loss, three phase unbalance, but also over voltage and under voltage protection, when this mode is turned on, when the working voltage is higher or lower than the setup value it can stop to protect the mechanical unit. 7. Backlit LCD display and programming keypad. The human interface modules, a display panel and a Switchboard, can be used to program and display the following technical parameters: * Three-phase current *Three-phase voltage * Active Power *Reactive Power * Apparent Power *Power factor *175 pieces of diagnostic and running data *Power Consumption. 8. Default Phase and Phase discrimination Protection When the phase order is default or connect wrong, the unit would not start and clue on the LCD screen. 9. Grounding automatic-alarming function. 10. Display the online detection of unit insulated resistance. (*as usersf+ requirement) 11. Communication and remote control. The Soft Controller can be configured to communicate via radio (and GSM or GPRS) or wire-line to computer in remote control center. The controller supports ModBus protocol. (*as usersf+ requirement) All in one sentence, The QYRK serial Soft-Start Switchboard has very important meaning for lengthen the mechanical unit life, reduce maintenance and the ESP colligate cost. Normal ESP switchboard doesn't have these features.
Product name: EL flashing panel, EL poster, EL advertising product The animated or flashing advertisement is the most attractive point compared with other products! When the panel is on, the poster turns into dazzling animated EL sheets. It is flexible, thin, lightweight and dynamic lighted signs. Depend on the different size, it can be powered by regular plug-in outlets or battery pack. Any customized picture is high welcomed! Specification: 1.Size: A6-A0, and any customized size 2.Thickness: 0.6mm 3.Brightness: 80-150cd 4.Life time: more than 10000 hours 5.Power supply: Input: DC12V/ AC90-240V Output: AC110V/800Hz. Features: 1.EL products is with high brightness, 85-150cd. It can attract peoplesí» eyes and show the best advertising effect! 2.Flashing program can be customized according to the picture and clientí»s request. 3.We could do any size, A6-A0, 1m*2m, and bigger size is also OK, we will connect the panels. 4.Super thin: 0.4-0.6mm, soft, can be bended for packing and it can also cut into any shape. 5.Long life time: more than 10000 hours 6.Warranty: 3 months. Application: Super market, subway, bus, taxi, night club, disco, drinking bar, caf, business center and so on. Standard packing, strong packing.
For over a quarter of a century, we have been associated with these electrical items and have sufficient knowledge and experience regarding quality. The electrical main switches offer the most cost effective, flexible and high performing solutions. These main switches exhibit the highest breaking capacity, have auxiliary contacts for electronic circuits and are compact in design. We have a wide range of circuit breaker equipment, like mcb . The range of mcb boards are highly durable and allow the installer maximum flexibility. This offers the choice of switch-disconnector incomers, rcd incomers, mccb incomers or direct connection.
We are manufacturing electric fitting pvc switch boards in different sizes as 4"x4", 7"x4", 8"x6", 8"x10" & 10"x12".We are also making cocealed boards. Our boards are flame retardant, 100% termite proof, dimensionally stable, 100% waterproof and available in attractive colors and glossy finish.
Size:20mm, 25mm
Size:20mm, 25mm
Embedded Boards
Electrical control panels Motor control panels , generator controls, engine control panels 24x24x12