Introducing our compact and efficient 3-cylinder diesel generator, offering a prime power output of 28 kW and 35 kVA. Its powered by the dependable Perkins 1103A-33G engine and features a Stamford PI144G alternator, ensuring consistent and reliable performance. Ideal for both backup power and continuous operation, this generator is designed to deliver dependable power with optimal efficiency.
Cummins Diesel Engine, Diesel Generator set YC6MK420-D31 60HZ/1500RPM,380/220V,400/230V,415/240V can be adjustable, Open Type, weatherproof type or soundproof type, trailer type and so on. Also have 60HZ/1800RPM,voltage is 220/127V,380/220V,440/254V can be option ATS can be option Controller brand: UK Deepsea, Czech ComAp, Denmark DEIF, Smartgen China Generator Standard Compose: Dongfeng Cummins Engine, model YC6MK420-D31. Meet the environmental temperature 40 water tank radiator, Driving belt cooling fans, with fan safety shield 24 V charging generators Generator: Single bearing generator, IP23 Grading Protection, H Insulation degree Shock absorber Dry air filter, Fuel filter, Oil filter Power output circuit breaker Standard control panel 12 V battery and battery connection cables Battery Charger Exhaust pipe, Bellows, Flange, Muffler set 8 hours base tank
Generator set for factories and enterprises with the need for autonomous power supply of more than 2000 kWt. (Gas piston unit of container design, power over 2.5 MW) Model: MTU 20V4000 GS Fuel: natural gas Manufacturer: "mtu A Rolls-Royce solution" Working principle: piston engine Condition: new Detailed specifications will be sent as a PDF file in messengers or by e-mail. In the presence of 5 pcs., geographically located in Turkey, ready to provide fast delivery to any city
Engine features: Certified by the Environmental Protection Agency (EPA) to conform to Tier III marine auxiliary standards. Closed cooling system Heat exchanger Oil drain valve Generator features: Remote start 12-pin connector Voltage regulation of ±1.0% Rotor and stator are coated with a high-bond epoxy varnish. Varnish helps prevent corrosion in high-humidity areas. Copper windings ensure minimal heat buildup. Insulation meets NEMA standards for class H insulation. Direct connected to the engine, the generator has sealed precision ball bearings with a precision-machined steel sleeve in the end bracket to prevent shaft misalignment and extend bearing life.
3 phase DC power 1250 kVA (1000 kW),emergency 1375 kVA (1100 kW). Silenced, 1500 rpm.Diesel engine Perkins 12 cyl. 45.842 ci.
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 800 Warranty 1 Year Rated power/speed 180KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 500 Warranty 1 Year Rated power/speed 92KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 400 Warranty 1 Year Rated power/speed 27KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 1500 Warranty 1 Year Rated power/speed 205KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 1150 Warranty 1 Year Rated power/speed 426KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 1400 Warranty 1 Year Rated power/speed 400KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Applicable Industries Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Farms, Home Use, Retail, Construction works , Energy & Mining, Other Place of Origin Hubei, China Weight 1900 Warranty 1 Year Rated power/speed 574KW Machinery Test Report Provided Video outgoing-inspection Provided Marketing Type Ordinary Product Warranty of core components 3 months
Output:1.5kw-6.0kw 1.AVR gives stable voltage and safe work 2.Circuit breaker protects overload operation 3.12.5L tank ensures 8 hours' continuous running 4.Low oil shutdown stops engine in emergency 5.Various sockets for different market. Brand new production, factory direct sales, you deserve it Welcome to contact me
Diesel Generator Sets & Spares
Sesame oil, prefabricated houses, containers, generators.
FP 250 Engine Engine Model : 1206A- E70TTAG2 Stand By kVA: 250 Stand By kW : 200 Prime kVA: 227 Prime kW : 182 Rated Current : 327 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1206A- E70TTAG2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 15.08:1 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged aftercooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 226 / 303 Prime Power Hp 204 / 273 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 25 Fuel Consumption (lt / h) Lt Full Load 50,6 Lt %75 LOAD 37,9 Lt %50 LOAD 25,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2550 Weight (Open) Kg 2120 Width (Silent) Mm 1300 Length (Silent) Mm 3900 Height (Silent) Mm 1980 Fuel Tank Capacity Lt 450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 165 Engine: Engine Model : 1106A-70TAG2 Stand By kVA: 165 Stand By kW : 132 Prime kVA: 150 Prime kW : 120 Rated Current : 216 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 18,2 : 1 Bore 105 Strok 135 Displacement Lt 135 Air Intake Turbocharged and Air Charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 149,1 / 202 Prime Power Hp 136 / 184 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 33,2 Lt %75 LOAD 24,5 Lt %50 LOAD 16,2 Frequency Hz Power kVA 165 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1950 Weight (Open) Kg 1710 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity Lt 250 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 110 Engine Model : 1104C-44TAG2 Stand By kVA: 110 Stand By kW : 88 Prime kVA: 100 Prime kW : 80 Rated Current : 144 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104C-44TAG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 18,2 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 80.7 / 109 Prime Power Hp 73.4 / 99 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 22 Lt %75 LOAD 16,9 Lt %50 LOAD 11,1 Frequency Hz Power kVA 110 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1480 Weight (Open) Kg 1290 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERK S Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.