Please click here to check who's online and chat with them.

Find Verified Diagnostic Kits Suppliers, Manufacturers and Wholesalers

Nov-29-22
Supplier From Liverpool, Merseyside, United Kingdom
Sep-01-22
Supplier From Mumbai, Maharashtra, India
May-18-22
Supplier From Burgess Hill, West Sussex, United Kingdom
Oct-31-16
 
SPECIFICATION
1. Test Functions: Blood glucose, Hemoglobin and cholesterol test system
2. Glucose Measuring Range:
20 ? 600 mg/dL(1.1 ? 33.3 mmol/L)
3.Hemoglobin Measuring Range:
6 ? 27 mg/dL(179 ? 1190 µmmol/L)
4. Cholesterol Measuring Range:
100 ? 400 mg/dL(2.5 ? 10.4 µmmol/L)
5. Memory:
200 memories for Glucose, 50 memories for Hemoglobin and 50 memories for Cholesterol
6. Test Time:
10 seconds for Glucose, 6 seconds for Hemoglobin and 150 seconds for Cholesterol
7. Operation Temperature:
14 ? 40 °C (57.4 - 104°F)
8. Operation Humidity:
= 2.6 for Hemoglobin ; >= 15µl for Cholesterol
12. Sample Type:
Capillary whole blood
13. Hematocrit Rage:
30 ? 55%
14. Power Supply:
CR2032 x1
15. Battery Life:
Approximately 1000 tests
16. Display:
LCD display (35 x 45mm)
17. Dimension:
88 (H) x 64 (W) x 22 (D)mm
18. Weight:
59.5 g (without battery)
19. Technology Used:
Electrode-based amperornetric and Amperornetric Enzyme Electrode
20. Time & Date Display
21. Glucose Average Result:
7 / 14 / 28 days
22. Power On & Off:
Automatically
23. Strip Type:
Siphonal Strip (Capillary Action)
24. Warranty :
2 Years

Contents of ET-3211
1. Meter
2. User's Manual
3. Blood Glucose / Cholesterol / Hemoglovin Test Strips
4. Lancets
5. Puncturer (lancing Device)
6. Pouch
7. Battery
8. Check Strip

Fasting Blood Glucose / Blood Sugar Levels Chart
Normal 70 - 100 mg/dL
Early Diabetes 101 - 125 mg/dL
Diabetic > 126 mg/dL
The Following Values are Expected Blood Glucose / Blood Sugar Levels for Non-Diabetics
Upon Waking - Fasting 70 - 99 mg/dL
After Meals 70 - 140 mg/dL
The Following Values are Targets for Diabetics
Before Meals 70 - 130 mg/dL
1 - 2 Hours after Starting a Meal < 180 mg/dL
Apr-11-17
 
Product name:POCT PCT/CRP/hsCRP Rapid Test Kit
Specification: 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized
Specimen: Whole blood/serum/plasma
Type:Cassette
MOQ: 10,000 PCS
Specimen:Human serum/plasma/whole blood
Corollary machine: POCT Analyzer blood diagnostic machine FA-LF100B
2.Application
PCT:
Sepsis Monitoring
20170121143136.png
Sepsis Diagnosis
20170121143156.png

(Note: The cut-off value 2.0ng/ml is for reference only. Clinical departments shall adjust according to patient's situation.)
CRP/hsCRP
- Differential diagnosis of virus infection and bacterial infection
- CRP relating with cardiovascular disease (CVD)
- Accurate early diagnosis in pregnant women with amniorrhexis premature delivery and ch

hsCRP
< 1.0 mg/L
Cardiovascular disease risk: Low risk
1.0-3.0 mg/L
Cardiovascular disease risk: Moderate risk
Anti-inflammatory therapy is recommended.
> 3.0 mg/L
Cardiovascular disease risk: High risk
Anti-inflammatory and antithrombotic therapy is recommended.



CRP
< 10 mg/L
Less possibility of bacterial infection or bacterium are eradicated
10-25 mg/L
Virus infection signal
When course is short, bacterial infection is possible. Re-check after hours.
25-50 mg/L
Virus/bacterial infection signal
50-100 mg/L
Usually bacterial infection
Virus infection is uncommon.
> 100 mg/L
Bacterial infection signal
Less possibility of virus infection
5096 Diagnostic Kits Suppliers
Short on time? Let Diagnostic Kits sellers contact you.
Apr-11-17
 
CTnI One Step Troponin I Rapid Test Kit
(Whole blood/serum/plasma)
1.Product description
Introduction:
Product name:
CTnI One Step Troponin I Rapid Test Kit
Specification:
Lateral-flow Immunofluorescence Chromatographic Assay 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized
Type:
Cassette
MOQ:
10,000 PCS

Analytical Range:
1.0~50ng/ml (Whole Blood); 0.1~50ng/ml (Serum/Plasma)
Specimen:
Human serum/plasma/whole blood
Manufacturer:
Hangzhou Laihe Biotech Co., Ltd.
Clinical significance
1. Diagnosis of various chest pain
2. Foundation of ACS diagnosis and risk stratification
3. Best markers for ACS prognosis
4. An aid in the diagnosis of myocardial infarction (injury)
5. Can improve clinical, economic and operational outcomes
Principle
Insert the sample cassette into Immunofluorescence Quantitative Analyzer. The detection system will scan the markers and bond zone to gain optical signals, and then analyze the signals to get the concentration of the tested sample.
Storage
Valid for 24 months under 4-30 °C with aluminum foil bag packing. Once opened, the cassette is valid for 1 hour.

2.Application
Clinical Laboratory, ED, ICU, CCU, Respiratory Department, Cardiology Department, Pediatrics Department, Surgery Department, Hematology Department, etc.
Apr-11-17
 
Tumor Marker PSA Prostate Specific Antigen Semi-Quantitative Rapid Test Strip Device Rapid Test Diagnostic Kit Accurate
Product name: PSA Prostate Specific Antigen Semi-quantitative Rapid Test Kit
Specimen: Whole blood/serum/plasma
Format: Strip/cassette
Specification: 25pcs, 40pcs, or customized
MOQ: 10,000 pcs
Sensitivity: 4ng/mL, 10ng/mL
Application: Specific antigen in prostate, help in diagnosis of early prostatic diseases.
Apr-11-17
 
We can provide various infectious diseases test kits as listed.

Product name
Cat. No.
Specimen
Packing
Chlamydia Rapid Test Device
ICH-502
Swab/urine
Cassette: 10 or 40pcs/box or Customized
HBsAg One Step Hepatitis B Surface Antigen Test Device
IHBsg-302
Serum/plasma
Cassette: 10 or 40pcs/box or Customized

HBsAg Hepatitis B Surface Antigen Rapid Test Device
IHBsg-402
Whole blood/serum/plasma
Cassette: 10 or 40pcs/box or Customized
HBsAg One Step Ultra Hepatitis B Surface Antigen Test Device
IHBsg-302U
Serum/plasma
Cassette: 10 or 40pcs/box or Customized
HCV Hepatitis C Virus Rapid Test Device
IHC-302
Serum/plasma
Cassette: 10 or 40pcs/box or Customized
HCV Hepatitis C Virus Rapid Test Device
IHC-402
Whole blood/serum/plasma
Cassette: 10 or 40pcs/box or Customized
HIV 1/2 Antibody Rapid Test Device
IHI-402
Whole blood/serum/plasma
Cassette: 10 or 40pcs/box or Customized
H. Pylori Antigen Rapid Test Device
IHPg-602
Feces
Cassette: 10 or 40pcs/box or Customized
H. Pylori Antibody Rapid Test Device
IHPb-602
Serum/plasma
Cassette: 10 or 40pcs/box or Customized
Syphilis Ultra Rapid Test Device
ISY-402U
Whole blood/serum/plasma
Cassette: 10 or 40pcs/box or Customized
Dengue Fever Rapid Test Device
IDE-402
Whole blood/serum/plasma
Cassette: 10 or 40pcs/box or Customized
Malaria P. f. /P. v. Rapid Test Device
IMA-422
Whole blood
Cassette: 10 or 40pcs/box or Customized
Apr-11-17
 
Product name: hCG One Step Pregnancy Test Kit,FSH One Step Menopause Rapid Test Kit ect.
Specimen: Urine
Format: Strip/cassette/midstream
Specification: 25pcs, 40pcs, or customized
MOQ: 10,000 pcs
Accuracy: > 99%
Storage: 4-30°C
Valid for: 24 months
Apr-11-17
 
Product name: TORCH IgM Rapid Combo Test Device
Format: Cassette
Specimen: Whole blood/serum/plasma
Test items: Toxo IgM, CMV IgM, Rubella IgM, HSV 1 IgM, and HSV 2 IgM
Valid for: 24 months

2.Features
-Customized sensitivity, printing color and packing
-Accurate, quiet, stable, convenient
-Latest production
-Competitive quality and price
-Easy payment and shipment
Oct-31-16

Tens & Ems Combo Machine

$1.00 - $35.00
MOQ: Not Specified
 
INTRODUCTION
Most of people experience muscle spasm, tight muscle or other chronic pain of some kind. Transcutaneous Electrical Nerve stimulation is convinced one of the most effective measure to relieve the pain and relax muscles. Our MH serious TENS EMS Body massage machines are designed to help someone suffered from it. Benefit from our TENS Body Massager right away, and you will find its amazing efficiency of pain relief and relaxation.

SPECIFICATION

MH8000 Combo Massage Machine

Channel
Dual

Intensity
0 - 80mA

Wave form
Asymmetrical rectangular biphasic pulse.

Power source
DC 9V

Size
13.6 (L) x 7 (W) x 2.65 (H) (cm)

Weight
162 grams (battery included)

Pulse Rate
2Hz - 20 Hz in 1 Hz/step and 20 - 150 Hz in 5 Hz/step.

Pulse Width
50uS - 300uS, 10uS/step.

Output mode
S, A, N, M, B, SD, MR

Contraction Time
2 - 90 seconds

Relaxation Time
2 - 90 seconds

Ramp Time
1 - 8 seconds

Timer
5 - 90 Minutes or continue.

Electrode Detection
Active in pulse width from 100uS to 300uS
Oct-31-16
 
The Digital otoscope has higher magnification and extensive field of view. It's easily to capture ear canal and tympanic membrane. Better visualisation can enhance learning, decision-making and patient outcomes.

Digital Otoscope Specifications
Handheld Device
Main Machine
Size 187 x 88 x 85 mm
Weight 186 g
Intended use Digital Otoscope
Using method Hand-held digital otoscope
Image System Light source Nature white LED light
Focus range 10 ~ 80 mm
Sensor CMOS
Resolution 640 x 480 pixels (VGA)
Focus system Fixed
Earcap No.4 (4.0 mm) and below
Display Intergrated display Full color TFT-LCD
Live image export AV out
Storage type Built-in SD Card (4GB)
Image mode Photo
Format JEPG
Capacit12,000 pictures
Data transmit Micro-USB
Power Battery 3.7 V/ 3000mAh Li-ion Battery with safety protection
Charger By Micro-USB
Energy indicator 2 stage display
Energy save Yes
Oct-21-17

Flu A Antigen Rapid Test Kit

$120.00
MOQ: Not Specified
 
Flu A H5 subtype Antigen Rapid Test Kit/Flu A H7 subtype Antigen Rapid Test Kit/Flu A H9 subtype Antigen Rapid Test Kit. They're highly sensitive, high specificity, and it's easy to use. Because the company is manufacturer, we can offer better quality at reduced prices.
Oct-20-17

Bvdv P80 Antibody Rapid Test

$120.00
MOQ: Not Specified
 
This rapid test kit is to detect p80 protein specific antibody of bvdv, which is accurate, sensitive and specific.
Aug-24-18
 
(1)The One Step Drug Screen Test Panel (Urine) is an immunoassay based on the principle of competitive binding.Drugs which may be present in the urine specimen compete against their respective drug conjugate for binding sites on their specific antibody.

(2)During testing,a urine specimen migrates upward by capillary action. A drug, if present in the urine specimen below its cut-off concentration, will not saturate the binding sites of its specific antibody coated on the particles. The antibody coated particles will then be captured by the immobilized drug conjugate and a visible colored line will show up in the test line region of the specific drug strip. The colored line will not form in the test line region if the drug level is above its cut-off concentration because it will saturate all the binding sites of the antibody coated on the particles.
Dec-20-17
 
1.Product description
(1)Product name: hCG One Step Pregnancy Test Kit
(2)Specimen: Urine
(3)Format: Strip/cassette/midstream
(4)Specification: 25pcs, 40pcs, or customized
(5)MOQ: 10,000 pcs
(6)Accuracy: > 99%
(7)Storage: 4-30°C
(8)Valid for: 24 months
Jan-16-18
 
A rapid test for the qualitative detection of antibodies (IgG and IgM) to Dengue virus in whole blood, serum, or plasma.
For professional in vitro diagnostic use only.
INTENDED USE
The Dengue IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to Dengue virus in human whole blood, serum, or plasma as an aid in the diagnosis of primary and secondary Dengue infections.

DIRECTIONS FOR USE
Allow the test device, specimen, buffer, and/or controls to reach room temperature (1530°C) prior to testing.
1.Bring the pouch to room temperature before opening. Remove the test device from the sealed pouch and use it as soon as possible.
2.Place the test device on a clean and level surface.
For Serum or Plasma Specimens:
Hold the dropper vertically, draw the specimen up to the Fill Line (approximately 5 μL), and transfer the specimen to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 L) and start the timer. See illustration below. Avoid trapping air bubbles in the specimen well (S).
For Whole Blood (Venipuncture/Fingerstick) Specimens:
To use a dropper: Hold the dropper vertically, draw the specimen 0.5-1 cm above the Fill Line, and transfer 1 drop of whole blood (approximately 10 µL) to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 uL) and start the timer. See illustration below.
To use a micropipette: Pipet and dispense 10 µL of whole blood to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 µL) and start the timer. See illustration below.
3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
Jan-16-18
 
A rapid test for the qualitative detection of circulating antigens of Plasmodium falciparum, Plasmodium vivax, Plasmodium ovale, Plasmodium malariae in whole blood.
For professional in vitro diagnostic use only.

Sensitivity
The Malaria P.f/ Pan Rapid Test Device (Whole Blood) has been tested with thin or thick microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f/ Pan Rapid Test Device (Whole Blood) is >99.9% relative to microscopy.
For Pan:
Relative Sensitivity: >99.9% (158/158) (97.6%100.0%)*
For P.f:
Relative Sensitivity: >99.9% (53/53) (93%100.0%)*
Specificity
The Malaria P.f/ Pan Rapid Test Device (Whole Blood) uses highly specific antibodies for Malaria P.f/ Pan antigens in whole blood. The results show that the specificity of the Malaria P.f/ Pan. Rapid Test Device (Whole Blood) is over 99.0% relative to microscopy.
Relative Specificity: >99.0% (324/327)(97.3%99.8%)*
Accuracy: >99.4%(535/538)(98.3%99.8%)*
* 95% Confidence Interval

Total Results211327538
Note: The comparison for Pan line has been only done with blood specimens positive with Plasmodium vivax specimen. The claims for Pan lines are based on scientific findings that Pan-malarial Aldolase is found in other malarial parasites including Plasmodium ovale and Plasmodium malariae.
Jan-16-18
 
Troponin I (CTnI) One Step Rapid Test Kit
(Whole blood/serum/plasma)
Product description

Product name:
CTnI One Step Troponin I Rapid Test Kit
Specification:
Lateral-flow Immunofluorescence Chromatographic Assay 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized
Type:
Cassette
MOQ:
10,000 PCS
Analytical Range:
1.0~50ng/ml (Whole Blood); 0.1~50ng/ml (Serum/Plasma)
Specimen:
Human serum/plasma/whole blood
Manufacturer:
Hangzhou Laihe Biotech Co., Ltd.
2.Clinical significance
(1)Diagnosis of various chest pain
(2)Foundation of ACS diagnosis and risk stratification
(3)Best markers for ACS prognosis
(4)An aid in the diagnosis of myocardial infarction (injury)
(5)Can improve clinical, economic and operational outcomes
Jan-16-18
 
In One Cup Cup Multi-drug One Step 2-15 Drug Test Simple Cup (Urine) CE Qualified (MOP/MET/KET/AMP/BAR/BUP/BZO/COC/COT/MDMA/THC/MTD/OPI/PCP/TCA)
5096 Diagnostic Kits Suppliers
Short on time? Let Diagnostic Kits sellers contact you.