Polyester spiral belt /polyester spiral mesh /polyester spiral fabric made from first-class monofilament, in reference to Finland Standard, has the characteristics of stable property and long work time. It is widely used in producing of paper, corrugated paper, paper for train fare, also used in filtration and sieving in environmental protection, pharmaceutical, mine, metallurgy, machinery, airspace and other fields. We can also produce Spiral dryer fabrics with Teflon material. (1)Benefits: No problems with the seam No marking High dimensional and diagonal stability Even tension profile High wear resistance Flat surface, not easily cracked Good air permeability Stable property against heat and moisture Low thermal shrinking Less elongation at heat Long lifespan (2)Appliocation: Dry section of paper machine Used as filter media Used as conveyor belt
Tzjw-d-101b, tzjw-s-301b, tzjw-d-101a, tzjw-s-301a Carton box
Type C and Type E air conditioning hose for cars. Thin wall and Thick wall. 5/16",13/32",3/8",1/2",5/8",etc Refrigerrant: R134a
Description Aerogel Insulation Felt/Panel is made of nano-silica aerogel as the main material and combined with glass fiber cotton or pre-oxidized fiber mat by special process.It is characterized by low thermal conductivity,certain tensile and compressive strength,and is a new type of thermal insulation material. Specification Model SACB-0-3 SACB-0-6 SACB-0-10 Thickness(mm) 3 6 10 Width(mm) 1400/1500(customizable) Color White Permitted useful temperature range(°C) -200~650 -200~650 Fiberglass composite: -200~650 Ceramic fiber composite: 600~1000 Density(kg/m³) 200±20 200±20 200±20 Linear expansivity 4.2Ã?10-6 Dimensional stability(max) 1% Test method GB/T 8811-2008 Compressive property (min),kpa,@10% 60 Test method GB/T 13480-2014 (min),kpa,@25% 120 Test method GB/T 13480-2014 Burning behavior A1 Test method GB/T 20285-2006 The smoke performance level SR-2 Drip content level ST-2 Smoke toxicity of the FED's value,(max) 0.1 Corrosion resistance pass Test method GB/T 3810.1-2006 Hydrophobicity,(%) >99.8 Test method GB/T 10299-2011 Tensile strength(min),(kpa) Fiberglass composite: 100 Ceramic fiber composite: 80 Test method GB/T 17911-2011 Remarks : Silica aerogel fiberglass and ceramic fiber technical parameters Advantages --Lower thermal conductivity coefficient Thermal conductivity coefficient less than 0.016w/(m,k)at room temperature, several times or even dozens of times lower than traditional heat preservation materials, and with better heat preservation effect. --Thinnest and lightest thermal insulating material Under the same heat preservation effect, the dosage of our companys SiO2 aerogel composite material is only 1/5 to 1/3 of traditional materials . So it can be applied to dense pipeline and narrow space and achieve a good effect of heat or cold preservation. And greatly convenient for installation and save the cost of the protective layer. --Water-proof and moisture-proofï¼?easy to store It is hydrophobic and porous with hydrophobicity of 99%. Application Construction: Interior and extrior wall, door, floor, ceiling, roof, partitions, fireproof door Cold Storage: fridge, freezer, refrigerators, cold storage, medical incubator, blood bank, medicine box, refrigerated container. Veicle: Engine heat shield, catalytic exhaust pipe Aerospace: Engine, black box Building materials industry furnace: All types industry kiln, including rotary kiln, shuttle kiln, roasted kiln Metallurgy: torpedo tank, steel ladle, tundish, coke oven door Machinery: industrial stove, electric stove, stove door, stove cover Instrumentation: stove temperature tracker, heat accumulator, data record protection, electric ceramic stove. Feature It has the thermal insulation performance and surface hydrophobicity and excellent flame retardant properties.
Special cold storage Low temperature laboratory Be designed as needed Provide researchers with comfortable environment ad the experimental conditions, saving energy and reducing consumption, suitable for colleges and universities, research institutes, large and medium-sized enterprise research and development institutions. Temperature can be designed as needed. Special cold storage for mushroom cultivation Provide the most appropriate environmental temperature for the edible mushroom cultivation. Applicable to edible fungus and mushroooms production enterprises.16-25 The optimum environmental temperature for the growth of fungus and mushrooms is from 16-25 Fresh keeping cold storage Ordinary fresh keeping cold storage-5-5, Providing appropriate storage temperature and prolong storage life for fresh preservation of fruits and vegetables or eggs, suitable for fresh preservation of fruits and vegetables or eggs. Suitable for fresh production and operation enterprises and farmers, such as fruits and vegetable or eggs. Cold storage Air controlling cold storage configure air controlling on the device on the basis of ordinary fresh keeping cold storage adjust the component ratio the air , such as oxygen , carbon dioxide etc as well as the humidity , in order to make fruits and vegetables into nearly hibernate state to achieve long-term preservation storage of fruit and vegetables products suitable for fruit and vegetable painting and management enterprises farms longistics centeers, etc Medium temperatrue cold storage proving economic and suitable freezing storage temperature for ordinary livestock meat and aquatic products suitable for general livestock meet aquatic products production or circulation enterprise shopping malls dining hall etc.
1.PVC crossflow cooling tower fill description: Marley MX75 is a crossflow film fill, which can provide you cold water in the present splash-fill cooling tower without sacrificing fan horsepower. No other eliminator could come close to MX75 eliminator’s low drift rate and low pressure drop.Now, virtually every eliminator is a nesting cellular PVC type design. Mx75 incorporates highly efficient cellular drift eliminators, which were integrally molded within the fill sheets. Compared with previous designs, these eliminators reduce drift emissions from the tower by a factor of ten or more! Less drift means your saving on your water bills and water treatment chemical expenses. And, you’ll virtually eliminate the nuisance caused by drift spotting on adjacent buildings and property. To save you even more, the drift eliminators discharge air directly toward the fan. Since the air is traveling in the right direction when it leaves the eliminators, you’ll save on fan horsepower. 3.PVC crossflow cooling tower fill technical data: 1. Light weight, high strength, good flame retardant performance, corrosion resistance, advance design, small ventilation resistance, strong hydrophilicity, large contact area, etc. 2. Size/Item: 915* any length, 1220*any length(3 feet*any length)( 4 feet*any length),1520mm* 3. Pitch: 19mm 4. Pitch thickness:0.28-0.38mm 5. Application temperature: 75°C~35°C 6. Application Cooling tower: Cross-flow cooling tower
Cooling Tower Fill is one of the most important components for exchange of gas and water in cooling tower. It is the major parts to improve the efficiency of cooling tower and make sure the economy and safe operation.With the development of the plastic industry, counter-current tower drench water plastic packing shape ladder wave, inclined corrugated fills, which has the heat dissipation, durable, good performance, ventilated small resistance, based on the easy and other advantages. Counter-flow cooling tower fill with a 19mm pitch. The larger sheet spacing is suitable for water quality slightly less than ideal. RF1900 is used in counter-flow or cross-flow cooling tower applications and is available in glued blocks 305mm wide x 305mm high, and either 1830mm or 2440mm long. RF1900 can also be cut to length to your specific requirements, or supplied as loose sheets.
Refrigerated Compressed Air Dryer A refrigerated compressed air dryer is a device used to remove moisture from compressed air by lowering its temperature. It is a widely used type of air dryer in various industrial applications where the presence of moisture can lead to equipment damage, corrosion, and decreased efficiency. How does a refrigerated air dryer work? Refrigerant dryers are the most commonly used dryers in the industry and consist of an air-to-air heat exchanger and an air-to-refrigerant heat exchanger. The heat exchangers remove moisture from your compressed air by condensation of water within.This is essential to protect compressed air systems and every piece of equipment fed by compressed air from the harmful effects of moisture. The most important criterion is to keep the relative humidity of compressed air below 50%. Both air-cooled and water-cooled refrigerant dryers are available. Basically, the dryers cool down the warm wet air coming from the compressor, When the temperature of compressed air reduces, moisture condenses and is drained from the compressed air with the help of a high-efficiency water separator. After that, compressed air is reheated to around room temperature so that condensation does not form on the outside of the pipe system. This heat exchange between ingoing and outgoing compressed air also reduces the temperature of the incoming compressed air, and as such reduces the required cooling capacity of the refrigerant circuit.
Dryer screen dries paper web after passing a press section by adhering the web to a steam heated cylinder. In the dryer section of paper machine, the paper sheet travels around large-diameter heated cylinders, remaining water is removed by evaporation. So dryer screen must be heat resistant, rugged, and designed for both drying efficiently and evenly. Our Dryer Fabrics lifetime is about 6-18 months generally.
Description Adopt Excellent PS engineering plastic with a certain quantity of anti-aging agent under injection process; ensure a strong anti-aging function with longer lifespan. Special design in window door connection part offers a better sealing when close up. Protection net connection change from button type to bolts & nuts type, which effectively avoid the damage in transportation. Reset Spring and Pulley support are all made of excellent stainless steel, Lifespan is extended. Added with special designed pull rod pulley which reduce friction and facilitate installation mostly by holding up pull rod or steel rope. Light trap can be offered in clients requests. Bolts connection gets the easy installation, save cost. Air guide plate can be offered in clients requests. Added spring enables air guide plate to adjust it�??s angle according to the window door op ening angle. Features 1. Dimensions: 600*325*160mm,600*300*160mm,645*310*160mm,690*300*160mm 2. Made from superior engineering plastic, air inlet anti-UV, anti-aging, and long lasting. 3. The use of a reasonably designed protective net helps prevent birds and insects. 4. With a 20 mm polystyrene insulation board filled inside, the air inlet effectively prevents heat dissipation in winter. 5. The patented pull is easy to open and close because rolling friction cusses low friction. 6. The reset spring made of quality stainless steel is durable and rust resistant. 7. During operation, please keep the pressure at the set value of the negative pressure gauge. 8. The air inlet features three opening angles for more reasonable ventilation. 9. Generally, air inlet close to exhaust fan are of small opening angle and those relatively far from the fan are of large opening angle, so as to achieve uniform ventilation. 10. WZH air inlets is convenient to install, which can be installed in a window area directly Installation notification: The installation wall must be in a same line; 15cm scope from the air inlet must be solid wall to enable catch expansion bolts(Hollow wall is prohibited); In avoid the rain flow backward, The Hole bottom inner side must be higher than outer side; Reserved wooden-frame must be in a same line with installation wall. Reserved Hole Dimension: 560mm X270mm Air Inelt Advantages: 1. Made of plastic injection molding, high strength, high toughness. 2. With UV resistant additive, air inelt has stronger anit-ageing ability, longer service life, better sealing, flexible opening, with anti-bird net. 3. Double springs ensure excellent sealing. 4. Can be controlled by manual winch or automatic winch.
The characteristics of curing heating systems: (1) high running cost is the highest consumption in heating system. (2) the heating element in the heating system occupies a larger space in the solidified oven, and the volume of the same size can be reduced, and the width becomes smaller. (3) the workpiece must keep a certain distance from the electric heating element, otherwise the local temperature will cause the color difference too high, which further reduces the available space in the curing furnace.
Cold storage.
Deutz air cooling and water cooling power machines and spare parts.
Air conditioning hose, fitting, power steering hose.
Cooling tower fill, tube settlers, spray nozzle, drift eliminator, air inlet louver,FRP grating,fiberflass duct rodder,cable pulley,cable roller,push pull rod,fish tipe.
Electric heating pad, electric blankets, electric foot warmer, usb heating shawl blankets, other heating products etc..Manufacturer, quality control, oem and odm services.
Frp/grp pipe, tank, cable tray, cooling tower, SMC water tank, FRP fan, FRP waste gas scrubber, central air conditioning terminal products.
Air conditioning parts, such as A/C compressor, A/C condenser, A/C evaporator, A/C fan motor, A/C fan, A/C hose, A/C hose crimping tool, A/C hose fittings, A/C o-ring, A/C expansion valve, A/C clutch, A/C control valve and automotive rubber hoses, such as auto air conditioning hose, auto brake hoses, power steering hoses, hydraulic hose.Manufacturer & exporter