Chemical, chemical raw material, auxiliaries, solvents, paint, textile fiber, rubber, plastic, paint drier, plasticizer, flame retardant, surfactant, additives, steel pipe, steel tube, stainless steel tube, stainless steel pipe, ms pipe, pipe fitting, flange, fasteners, steel wire.Transportation agent,customs clearance service,
Material: Bamboo base embryo, crystal round edge mosaic Application: It can be used for warm-up activities such as early childhood education for children, with simple and quick operation. It can exercise children's image cognition, concentration, fine movements, hand foot coordination, resilience, self-confidence, logical thinking, artistic aesthetics, and requires adult accompaniment for production for younger children.
Tumbler Size : 20oz each Tumblers are double wall insulated stainless steel and can hold hot and cold drinks. -Printing directly on to Tumbler -No Vinyl or Expoxy Each of our stainless steel tumblers is custom-hand-made of SUS 304 body and premium material lid. The only drink lid to keep your water, beer or favorite drink locked in the tumbler. Tightly A durable coat of color won't fade, peel or crack through extended field use. The double wall insulated tumbler with a vacuum between helps your drink to keep its temperature from 3 to 4 hours What is a Flatbed UV Printer? Flatbed UV Printer usually use UV curable in made of acrylic monomers that are then exposed to strong UV light to cure or polymerize them. The adjustable printing bed makes it possible to print on surface ranging in thickness from a sheet of paper oftern up to as much as serval inches.
Electricity System SPD, M-GDT, MOV, Signal System SPD Feeder System SPD
Follow Current turn-off metal-ceramic GDT Two-electrode metal-ceramic GDT Three-electrode metal-ceramic GDT SMT metal-ceramic GDT
Acceptable Customization
ON SEMI, FCM8202QY, the year 2021 qty 2500 pcs
Halbach array is a special arrangement of permanent magnets that augments the magnetic field on one side of the array while cancelling the field to near zero on the other side.[1] This is achieved by having a spatially rotating pattern of magnetisation. The rotating pattern of permanent magnets (on the front face; on the left, up, right, down) can be continued indefinitely and have the same effect. The effect of this arrangement is roughly similar to many horseshoe magnets placed adjacent to each other, with similar poles touching.
Ndfeb magnet, magnetic assembly, ferrite magnets, smco, halbach array magnet, surge protection device, gas discharge tube, lightning protection earthing system, spd, gdt, arrester, surge, lightning.
We have strong sintered AlNiCo permanent magnet production scale, can produce the performance of Alnico2-8 grades. And annual output nearly 800 tons. AlNiCo magnet is suitable for producing complex, light, thin, and small products, and is widely used in instrumentation, communications, magnetoelectric switches, and various sensors. AlNiCo products are mainly used in automotive parts, instrumentation, electroacoustics, motors, nuclear power, teaching, aerospace and other fields. It has the characteristics of low temperature coefficient, high temperature resistance, humidity resistance, not easy to oxidize and good working stability.
Description : The most powerful magnets commercially available Manufactured by a powder metallurgical process involving the sintering of powder compacts under vacuum Grinding and slicing possible Very reactive with moisture and oxygen A variety of Coatings can applied depending on the environment of the application Applications : various types of electric motors, engineering equipment, medical equipment, audio apparatus and household appliances
Salted Beef Omasum. We produce high quality Dry Salted Beef Omasum . PRODUCT SPECIFICATION: MOISTURISE LESS THEN 2% NO SALT INSIDE OF LEAVES HALF OF 1% ROUND CUTTING NO BROKEN LEAVES NO WHITE SPOTS NO FAT NO BLEACH WASH Packing: 40 KG IN 1 PP Bags
Meat, yarn and stone.
As for Urine Reagent Analysis Strip Uncut Sheets , we have various parameters ranging from 1 to 12 . We can provide you strip and uncut sheet URS format with high quality and competitive price PRINCIPLE AND EXPECTED VALUES URS Ascorbic acid: This test involves decolorization of Tillmann's reagent. The presence of ascorbic acid causes the color of the test field to change from blue-green to orange. Glucose: This test is based on the enzymatic reaction that occurs between glucose oxidase, peroxidase and chromogen. Glucose if first oxidized to produce gluconic acid and hydrogen peroxide in the presence of glucose oxidase. The hydrogen peroxide reacts with potassium iodide chromogen in the presence of peroxidase. The extent to which the chromogen is oxidized determines the color which is produced, ranging from green to brown. Low amounts of glucose are normally excreted in urine.3 Glucose concentrations as low as 100 mg/dL, read at either 10 or 30 seconds, may be considered abnormal if results are consistent. At 10 seconds, results should be interpreted qualitatively. For semi-quantitative results, read at 30 seconds only. URS Bilirubin: This test is based on azo-coupling reaction of bilirubin with diazotized dichloroaniline in a strongly acidic medium. Varying bilirubin levels will produce a pinkish-tan color proportional to its concentration in urine. In normal urine, no bilirubin is detectable by even the most sensitive methods. Even trace amounts of bilirubin require further investigation. Atypical results (colors different from the negative or positive color blocks shown on the color chart) may indicate that bilirubin-derived bile pigments are present in the urine specimen, and are possibly masking the bilirubin reaction.
INTENDED USE The test kit utilize purified Chlamydia Trachomatis Antibody antigen, based on GIFA principle and use indirect method to detect Urea Plasma Urealyticum antibody in human serum. TEST PROCEDURE 1. Remove the test kit and put it at room temperature (for about 20-30mins) before testing. 2. Add 1 drop of Wash Buffer into the hole and allow the liquid soak the membrane completely. 3. Add 150l of the serum specimen into the hole and allow it to sufficient absorption. 4. Add 3 drops of Colloidal Conjugate into the hole and allow it to sufficient absorption. 5. Add 3 drops of Wash Buffer into the hole and allow it to sufficient absorption. Read the results within 3 minutes. STORAGE The kit can be stored at room temperature (2-30C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
INTENDED USE Feline Panleucopenia Virus Ag Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Feline Panleucopenia Virus (FPV Ag) in cat's feces or vomit. PRINCIPLE OF THE ASSAY Feline Panleucopenia Virus(FPV) Ag Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough Panleucopenia Virus antigen in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Panleucopenia Virus antigen in the sample. INTERPRETATION OF RESULTS Positive: The presence of both C band and T band, no matter T band is clear or vague. Negative: Only clear C band appears. Invalid: No colored band appears in C zone, no matter whether T band appears. STORAGE The kit can be stored at room temperature (2-30�°C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
INTENDED USE Feline Immunodeficiency Virus Ab Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Feline Immunodeficiency Virus antibody (FIV Ab) in cat's blood. PRINCIPLE OF THE ASSAY Feline Immunodeficiency Virus Ab Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FIV antibody in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FIV antibody in the sample. INTERPRETATION OF RESULTS Positive: The presence of both C band and T band, no matter T band is clear or vague. Negative: Only clear C band appears. Invalid: No colored band appears in C zone, no matter whether T band appears. STORAGE The kit can be stored at room temperature (2-30C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
1. INTENDED USE FIV Ab + FeLV Ag Combined Rapid Test is a combined cassette to differentially diagnose the presence of Feline Immunodeficiency antibody and Feline Leukemia Virus antigen in cat's blood. Assay Time: 10-15 min Sample: serum, plasma or whole blood 2. PRINCIPLE OF THE ASSAY FIV Ab + FeLV Ag Combined Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has two testing windows. Each testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FIV antibody or FeLV antigen in the sample, a visible T band will appear in the corresponding testing window. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FIV antibody or FeLV antigen in the sample. 3. KIT COMPONENT - 10 foil pouches, each containing a cassette,pipette and desiccant - 10 assay buffer tubes (0.5 mL each) - 10 centrifugal tubes - Product Manual
One Step Influenza A Test is a rapid qualitative assay that detects influenza type A (including the subtype H1N1) nucleoprotein antigen extracted from the nasal swab specimen. The device is used to aid in the diagnosis of influenza type A infection. For in vitro diagnostic use only. For professional use only. Influenza A SUMMARY Influenza (commonly known as flu) is a highly contagious, acute viral infection of the respiratory tract. It is a communicable disease that is easily transmitted through the coughing and sneezing of aerosolized droplets containing live virus. Influenza outbreaks occur each year during the autumn and winter months. There are three types of influenza viruses: A, B, and C. Only influenza A viruses are further classified by subtype on the basis of the two main surface glycoproteins hemagglutinin (HA) and neuraminidase (NA). Influenza A subtypes and B viruses are further classified by strains. Humans can be infected with influenza types A, B, and C viruses. Subtypes of influenza A that are currently circulating among people worldwide include H1N1, H1N2, and H3N2 viruses. Influenza B viruses can cause morbidity and mortality among humans, but in general are associated with less severe epidemics than influenza A viruses. Although influenza type B viruses can cause human epidemics, they have not caused pandemics. Influenza type C viruses cause mild illness in humans and do not cause epidemics or pandemics. Influenza A PRINCIPLE One Step Influenza A Test is a rapid immunochromatographic test for the visual detection of influenza type A antigen (nucleoprotein) extracted from the nasal swab specimen. The test adopts double antibody sandwich method. When the extracted specimen is added into the test device, the specimen is absorbed into the device by capillary action, mixes with antibody-dye conjugate, and flows across the membrane pre-coated with influenza type A monoclonal antibody. When the influenza type A antigen levels are at or above the target cutoff (the detection limit of the test), type A antigen in the specimen binds to the specific antibody-dye conjugate and are captured by influenza type A monoclonal antibody immobilized in the relative site of test region T of the device. This produces a colored test band in the test region. When the influenza type A antigen levels are zero or below the target cut off, there is not a visible colored band in the test region of the device. This indicates a negative result for influenza type A.
Intended Use The One Step HAV IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Hepatitis A Virus (HAV) in Whole Blood /Serum / Plasma to aid in the diagnosis of Hepatitis A Virus. Summary Hepatitis A is an acute, usually self-limiting disease of the liver caused by hepatitis A virus (HAV). HAV is transmitted from person to person, primarily by the faecal-oral route. The incidence of hepatitis A is closely related to socioeconomic development, and seroepidemiological studies show that prevalence of anti-HAV antibodies in the general population varies from 15% to close to 100% in different parts of the world. One step HAV IgG/IgM Test is a simple, visual qualitative test that detects Hepatitis A Virus antibodies in human Whole Blood /Serum / Plasma. The test is based on immunochromatography and can give a result within 15 minutes. Principle The One Step HAV IgG/IgM Test is a qualitative membrane strip based immunoassay for the detection of Hepatitis A Virus antibodies (IgG and IgM) in Whole Blood /Serum / Plasma. The test device consists of: 1) a burgundy colored conjugate pad containing HAV recombinant envelope antigens conjugated with Colloid gold (HAV conjugates) and rabbit IgG-gold conjugates,2) a nitrocellulose membrane strip containing two test bands (T1 and T2 bands) and a control band (C band). The T1 band is pre-coated with the antibody for the detection of IgM anti-HAV, T2 band is coated with antibody for the detection of IgG anti-HAV, and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. IgG anti-HAV, if present in the specimen, will bind to the HAV conjugates. The immunocomplex is then captured by the reagent pre-coated on the T2 band, forming a burgundy colored T2 band, indicating a HAV IgG positive test result and suggesting a recent or repeat infection. IgM anti-HAV if present in the specimen will bind to the HAV conjugates. The immunocomplex is then captured by the reagent coated on the T1 band, forming a burgundy colored T1 band, indicating a HAV IgM positive test result and suggesting a fresh infection. Absence of any T bands (T1 and T2) suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the T bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Storage and Stability Store as packaged in the sealed pouch at room temperature or refrigerated (4-30 or 40-86). The test device is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.