Main features: 1.MCU processing, anti-false alarm efficiently 2.Double temperature compensation 3.Pulse count adjustment 4.Anti white light interference 5.Anti RF interference(20V/m-1GHz) 6.Fresnel lens 7.Wall / corner mounted 8.Alarm output NC / NO optional 9.SMT manufacture technology 10.Execute criterion: GB10408.1, GB10408.5
Main features: 1.MCU processing, anti-false alarm efficiently 2.Double temperature compensation 3.Pulse count adjustment 4.Anti white light interference 5.Anti RF interference(20V/m-1GHz) 6.Fresnel lens 7.Wall / corner mounted 8.Alarm output NC / NO optional 9.SMT manufacture technology 10.Execute criterion: GB10408.1, GB10408.5
Main features: 1.MCU processing, anti-false alarm efficiently 2.Double temperature compensation 3.Pulse count adjustment 4.Anti white light interference 5.Anti RF interference(20V/m-1GHz) 6.Fresnel lens 7.Wall / corner mounted 8.Alarm output NC / NO optional 9.SMT manufacture technology 10.Execute criterion: GB10408.1, GB10408.5
Main features: 1.Screwing-type mounting bracket, more stable 2.Adjustable detecting distance 3.Auto temperature compensation 4.Low power indication 5.Tamper alarm function 6.Alarm delay optional 7.Anti RF(20V/m -1GHz) 8.Wireless signal output 9.Low power consumption design 10.SMT process, anti-RFI, anti-EMI
Main technical parameters: Power supply voltage: 220V/AC ~ 240V/AC Power frequency: 50 ~ 60Hz Ambient Light:
operating voltage DC 9-16V consumption current â?¤18mA(DC12V) operating temp -10ºC~+50ºC installation mode ceiling mounted installation height about 2.5~6m detecting distance Ï?8m detecting angle 360 degrees alarm output N.O./ N.C. optional anti-dismantle switch N.C. dimension Ï?106*36mm
operating voltage DC 9-16V consumption current â?¤18mA(DC12V) operating temp -10ºC~+50ºC installation mode ceiling mounted installation height about 2.5~6m detecting distance Ï?8m detecting angle 360 degrees alarm output N.O./ N.C. optional anti-dismantle switch N.C. dimension Ï?106*36mm
Product Description: SR-902 Main Features: Auto reset after alarm MCU process Sensor with high stability and low power consumption Detecting natural gas and LPG SMT adopted Technical specification: Operating voltage: AC 220V or DC 9-16V Standby current: less than 90mA or less than 30mA (low power consumption) Alarm current: less than 100mA or less than 40mA (low power consumption) Rated power: less than 3W (AC 220V) Operating temp.: -10 to +50 degrees Working humidity: less than 95%RH Alarm mode: network output / sound & flash alarm / RF Alarm volume: more than 85dB/m Alarm density: 10%LEL Alarm output: relay output (N.C.and N.O. optional) / RF signal Dimension: 70L*40W*110Hmm
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g
H2-BF Hydrogen Sensor H2 Sensor Description Alphasense is expanding its line of electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Hydrogen (H2) The Hydrogen sensor has excellent ppm sensitivity for low concentrations to 2,000ppm H2. The very low sensitivity to CO makes this one of the most selective Hydrogen sensors on the market. As with all Hydrogen sensors, temperature compensation for sensitivity must be applied carefully. Available in A series. H2-BF Hydrogen Sensor H2 Sensor Specifications * Range: 5,000 ppm H2 limit of performance warranty * Sensitivity: 10 to 25 nA/ppm in 400ppm H2 * Response time t90: < 55s from zero to 400ppm H2 * Resolution: < 0.8 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh * Weight: < 13g
Remote Particle Counter Model P235 The P235 remote particle counter measures 0.5 µm and 5.0 µm with a flow rate of 0.1 CFM (2.83 LPM). Integration is easy into a real-time monitoring or building management system via Modbus RTU or Modbus ASCII. The P235 is the smallest remote particle counter in the market and has easy mounting options. The P235 complies with ISO 21501-4 and includes a 2 year limited warranty. P235 Remote Particle Counter Features & Benefits * Measures 0.5 µm and 5.0 µm * 0.1 CFM (2.83 LPM) flow rate * Measures 2 channels of simultaneous data * Long life laser diode * Modbus RTU or Modbus ASCII outputs * Concentration limit of 2,000,000 per ft3 * Complies with ISO 21501-4 and JIS B9921 standards * Lightweight stainless steel enclosure * Easy to clean and wipe down * 2 year limited warranty
RF Microwave Meter Measure the electromagnetic field radiation intensity that is produced from welding equipment, microwave oven leakage, and other environmental safety concerns The Microwave Meter is calibrated precisely on the frequency value 2.45 GHZ (microwave oven). Features maximum and minimum hold, an audible alarm, and a zero adjustment to eliminate background EMF. The display also indicates overload and low battery. Comes with a soft carrying case and standard 9V battery, which provides approximately 100 hours of use. Dim: 5" x 2" x 1¼" (127 x 51 x 32 mm). Weight: 5.4 oz (153 g). 840046 RF Microwave Meter Specifications * Display: 3¾ digits, maximum reading 3999 * RF Power Density: 0.003 to 2.700 mW / cm2 * RF Frequency: 50 MHz to 3.5 GHz * Microwave Frequency: 2450 MHz * Resolution: 0.001 mW / cm2 * Accuracy: ±2 dB at 2.45 GHz ±50 MHz * Operating Temperature: 41 to 104 deg F (5 to 40 deg C) * Operating RH:
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously. Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide. Proven in the field over many years, these sensors perform well even under long term, challenging conditions. * Range: 1000 ppm CO limit of performance warranty * Range: 100 ppm H2S limit of performance warranty * Sensitivity: 27 to 55 nA/ppm in 400ppm CO * Sensitivity: 90 to 160 nA/ppm in 20ppm H2S * Response time t90: < 25 (s) from zero to 400ppm CO * Response time t90: < 30 (s) from zero to 20ppm H2S @ 20 deg C * Temperature range: -30 to 50 deg C * Humidity range: 15 to 90 %rh continuous * Pressure range: 80 to 120kPa
Carbon Monoxide Sensor CM8 CM8 Carbon Monoxide Sensor Features: 1. More than ten years long life, electrochemical principle 2. Low sensitivity to ethanol; 3. Can reduce the influence of various interference gases, good linear output characteristics; 4. Consistency is very good; 5. The carbon monoxide gas selectivity and repeatability is very good; 6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship; 7. The leading production technology and new advanced materials; 8. Electrolyte pollution, materials comply with RoHS requirements; 9. Strong anti-interference; 10. The shell thicker will never rust, the new material used in component feet is conductive. CM8 Carbon Monoxide Sensor Typical Applications: 1. Carbon monoxide detector alarms 2. Car alarms 3. Smart furniture 4. Commercial carbon monoxide detector 5. Industrial carbon monoxide detector 6. Indoor parking ventilation control 7. Portable carbon monoxide concentration meter 8. CO detection alarm. CM8 Carbon Monoxide Sensor Main parameters: * Carbon monoxide detection range: 0-10000ppm * Detection accuracy < 3% * Putput current: 0.8-2.0nA / ppm * Response time:
Combustible gas detector G-series for wall mounting G-series Combustible Gas Detectors Gases * Methane, CH4 * Liquid Petroleum Gas, LPG * Hydrogen, H2 * Propane, C3H8 * Ethylene, C2H4 * Ethyl alcohol, C2H5OH * Methanol, CH3OH * Acetone, C3H6O * Isopropyl alcohol, C3H8O * Iso/n-Butane, C4H10 * Toluene, C7H8 * Petrol Vapors On request: other combustible gas detectors G-series Combustible Gas Detectors Features * Pellistor (Catalytic Bead) sensor * Power supply 24 Vdc for output 4-20 mA * Power supply 24 Vac for output 2-10 Vdc * Measuring ranges: see ordering on page * IP65 enclosure with quick locking screws * Digital measurement value processing incl. temperature compensation * Internal function control with integrated hardware watchdog * Data / measured values in micro controller of sensor unit, therefore simple exchange uncalibrated calibrated * High accuracy, selectivity and reliability * Low zero point drift * Hardware & software according to SIL2 compliant development process * Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration G-series Combustible Gas Detectors Options * LCD display * LCD display for values & operation, 2 x open-collector for horn & warning lamp. * Duct mounting set available for sensing combustible gas in ventilation ducts.
PSMU Series PM2.5/PM1.0 Particle Sensor Description PSMU Series, in which SAMYOUNG S & C's 20years knowledge and technology are concentrated, is a PM2.5/PM1.0 dedicated sensor with a radical improvement for detection capability at ultra-fine particle range - 0.3μm~1.0μm, which assures PM2.5/PM1.0 weight concentration values more accurate than conventional presumptive sensors. PSMU Series which performs higher accuracy along with improved sensitivity than conventional sensors provides reliable information to users enabling more accurate and sophisticated control in the applications such as air purifiers, air conditioners and air quality measuring devices. PSMU Series PM2.5/PM1.0 Particle Sensor Features * Detectable Particle Size - 0.3m Real-time PM2.5/PM1.0 * UART Output - g/m3 * Excellent Accuracy * High Linearity and Uniformity * Market-proven Reliability and Durability PSMU Series PM2.5/PM1.0 Particle Sensor Applications * Air Solution Products (Air Purifier, Air Conditioner and etc.) * HVAC Control System * Smart IAQ Device * Outdoor Particle Sensing Device PSMU Series PM2.5/PM1.0 Particle Sensor Product Specifications (Ta=25'C) * Detectable Size: m * Effective Range: 0 ~ 500 g/m3 * Maximum Range: 0 ~ 900g/m3 * Response Time: 1sec * Supply Voltage: DC 5.0V±10% Ripple 30mV or Less * Current Consumption: Typ. 85mA * Output Signal: UART * Operating Temperature: -10 ~ 65'C * Operating Humidity:
SO2-AE Sulfur Dioxide Sensor SO2 Sensor Description Alphasense Sulfur Dioxide gas sensors operate using proven fuel cell technology. SO2-AE Sulfur Dioxide Sensor sizes: 20mm diameter, the industry standard size for portable gas detectors The SO2 range provides OEMs with reliable sensors for use in a variety of applications. Strong signal levels combined with low zero current allows resolution below 1ppm and an operating range for safety applications up to 2,000ppm. The sensors are designed for use in both fixed site and portable instrumentation. The SO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. SO2-AE Sulfur Dioxide Sensor SO2 Sensor Specifications * Range: 2,000ppm limit of performance warranty * Sensitivity: 55 to 80nA/ppm in 400ppm SO2 * Response time t90: < 30s from zero to 400ppm SO2 * Resolution: < 1.5 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120 kPa * Humidity range:15 to 90 % rh continuous * Weight: < 6 g
CL2-A1 Chlorine Sensor (CL2 Sensor) Description Alphasense Chlorine gas sensors operate using proven fuel cell technology. CL2-A1 Chlorine Sensor size: 20mm diameter, the industry standard size for portable gas detectors The Cl2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 20ppb and an operating range from +0 to 20ppm. The sensors are suitable for inclusion in fixed installation sensing heads and portable safety instruments. These sensors have improved transient response to humidity changes compared to competitors' equivalent sensors. The Cl2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. CL2-A1 Chlorine Sensor (CL2 Sensor) Specifications * Range: 20 ppm limit of performance warranty * Sensitivity: -350 to -750 nA/ppm in 10ppm Cl2 * Response time t90: < 60s from zero to 10ppm Cl2 * Resolution: < 0.02 RMS noise * Operating life: > 24 months * Temperature range: -20 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 %rh continuous * Weight: < 6 g
TOCON_B4 UVB+UVC SiC based UV photodetector with integrated amplifier Properties of the TOCON_B4 UV Photodetector * UVB+UVC SiC based UV photodetector in TO5 housing with diffusor * spectral response compliant to CIE087 * 0 - 5 V voltage output * peak wavelength at 280 nm * max. radiation (saturation limit) at peak is 7.5 μW/cm2 * Applications: UVB irradiation measurement TOCON_B4 UV Photodetector Specifications * Typical Responsivity at Peak Wavelength: 670mV/µW/cm2 * Wavelength of max. Spectral Responsivity: 280nm * Responsivity Range: 243 - 303nm * Supply Voltage: 2.5 - 5V * Dark Offset Voltage: 50µV * Temperature Coefficient at Peak: < -0.3%/K * Current Consumption: 150µA * Bandwidth (-3 dB): 15Hz * Risetime (10-90%): 0.182s * Operating Temperature: -25 ~ +85'C * Storage Temperature: -40 ~ +100'C * Soldering Temperature (3s): 300'C
SG01L-5LENS Concentrator lens SiC based UV photodiode Avirtual = 55 mm2 Properties of the SG01L-5LENS UV Photodiode * Broadband UVA+UVB+UVC, PTB reported high chip stability, for flame detection * Radiation sensitive area A = 55 mm2 * TO5 hermetically sealed metal housing with concentrator lens, 1 isolated pin and 1 case pin * 10µW/cm2 peak radiation results a current of approx. 700 nA SG01L-5LENS UV Photodiod Specifications * Typical Responsivity at Peak Wavelength: 0.130/AW * Wavelength of max. Spectral Responsivity: 280nm Responsivity Range: 221 - 358nm * Sensitive Area (chip size = 0.20 mm2): 55mm2 * Dark Current (1V reverse bias): 3.5fA * Capacitance: 250pF * Short Circuit (10µW/cm2 at peak): 700nA * Temperature Coefficient: < 0.1%/K * Operating Temperature: -55 ~ +170'C * Storage Temperature: -55 ~ +170'C * Soldering Temperature (3s): 260'C * Reverse Voltage: 20V