Fiber optic products.
THHN cable.
Warm patches heats up, using iron powder, activated carbon, vermiculite and other raw materials for oxidation reaction. The product cannot react before use, so the material of the packaging bag is very special, consisting of a raw material layer, a gelatin layer and a non-woven bag. When in use, let the inner bag be exposed to the air, the oxygen in the air enters through the breathable membrane, and it can generate heat.
Basic Parameters rated Power(kw) 15 Survival Wind Speed(m/s) 45 Max Power(kw) 16 Working Wind Speed(m/s) 1-25 Rated Voltage(v) 384/560 Rated Wind Speed(m/s) 9 Rated Rotation(r/min) 200 Blade Length(m) 4.30 Cut-in Wind Speed(m/s) 1 Blade Material FRP Cut-out Wind Speed(m/s) 25 Generator Life(year) 20 Some Key Technology Control Method Adjust speed method centrifuge variable pitch Brake Method electromagnetic Generator Generator Configuration 3-phase 380/220v 50/60hz Generator Type 3-phase permanent magnet Protect Class IP54
basic parameters rated power(kw) 30 survivel wind speed(m/s) 45 max power(kw) 32 wind wheel diameterm(m) 11.86 rated voltage(v) 384/560 blade length(m) 5.63 rated revolution(r/m) 150 swept area(m2) 99.53 cut-in speed(m/s) 1 blade material FRP cut-off wind speed(m/s) 25 generator life 25 sone key technology control method adjust speed method pneumatic pitch brake method mechanical generator generator configuration 3-phase 380/220v 50/60hz generator type 3-phase permanent magnet AC protect class IP54 blade technology resin is imported from american ashland,acuum slip casting, no bubble ,high strongth controller SIEMENS PLC pass ISO9001 and Europe CE
AirMMax roots blower is three lobe type roots blower with pressure reaching up to 150kpa in single stage roots blower and pressure reaching up to 200kpa in double stage roots blower, air capacity reach up to 30000m3/hour, which cover most water treatment plant, sewage treatment plant and effluent treatment plant in industrial and municipal wastewater treatment plant. Roots blower inculds: blower body motor , base , inlet sliencer, outlet sliencer, safety valve, pressure gauge, check valve, flexible joint, belt cover, bolts&nuts
Wind turbine, wind power generator, windmill Wind solar hybrid system.
Electric blanket.
Bearing, small electric equipment.
Turbine components for gas turbines, steam turbines, and various engine turbocharger accessories, such as turbines, blades, turbine discs, turbine nozzle, and guide vanes..
Magnetron, crisp plate ( pizza plate), transformer, motor, hv capacitor, diode, fuse, glass tray.
Wires and cables.
After ozone is dissolved in water, ozone water can quickly kill bacteria,fungus,escherichia coli,viruses and other microorganisms and it also can oxidize oganic matter completely with high oxidative capacity. it can achieve disinfection,sterilization,deodorization and prevention of infectious diseases spread by ozone oxidatio to swimming pool water,at the same time,ozone can oxidize iron,manganese and other metal ions in water and decompose micro organism of scattered ray in the water to improce water clarity and make water to show a beautiful blue color. the use of ozone treatment for swimming pool water is currently widely used in the world. ozone treatment could ensure the water quality to reach the international swimming federation standard and can not be replaced by other disinfection methods.
This AN8721PV3(F) series AC/DC power analyzer adopts STM32 controller as the core and supplemented by FPGA, using direct sampling and intelligent identification technology, widely used in electrical measurements of single-phase electrical equipment, such as voltage, current, power, power factor, frequency, electrical energy, time etc., wide range, 4-window LED highlight, simple operation, U disk read/write, serial communication, parameter alarm, voltage/current ratio settings and other functions, multi-purpose, accurate and durable. Features: AC/DC universal wide-range, DC ~ 4kHz bandwidth, load adaptability; Reliable, stable, compact, light; High measurement speed, up to 0.25s refresh rate; Voltage/current ratio setting, easy expansion; Voltage, current, power over-limit sound and light alarm, quick identification of abnormal products; Standard RS-232 or RS-485 serial port, MODBUS communication, test automation; Optional digital I/O, remote input and alarm signal output. Applications: Strict industrial site type test; High temperature aging room test; Home appliances, commercial appliances line standby power measurement; Power tools test; Lighting test.
AN87500(F) multi-channel power analyzer is specially designed for multi-channel AC/DC power measurement, suitable for power measurement of most electrical appliances, power supplies, motors, inverters and other products. The product takes the high-speed DSP processor as the core, adopts 16-bit high-speed high-performance AD direct sampling method for data acquisition, and can realize multi-channel simultaneous measurement, covering: voltage, current, power, peak voltage, peak current, power factor, crest factor, frequency, electric energy, current integral, efficiency, harmonic content and 3-phase electrical parameters, with serial communication (RS232/RS485, GPIB), remote control, alarm parameter preset and so on, supporting 1P2W/1P3W/3P3W/3V3A/3P4W and other wiring methods, meeting testing requirements of various power supply. Features: Multi-channel: 1~6 channels, flexible configuration of 1~6 single-phase, three-phase three-wire Ã?? 2, three-phase four-wire Ã?? 2, four-phase (DC+ three-phase three-wire) and other modes, satisfy test requirements of varies load (air conditioner, converter, inverter, motor); High accuracy: high-speed DSP processor, 16-bit high-speed high-accuracy AD converter, accuracy up to 0.1%, 100ms display cycle; Wide power range: current up to 50A for a single channel (optional 20A, 10A, 5A, 2A, 1A etc. or combination), minimum 0.lmW power resolution, satisfy test requirements of standby power consumption and rated power; Broadband: AC/DC signals, power measurement bandwidth: DC, 0.5Hz~100kHz, satisfy power test requirements of varies standard and non-standard sine wave load; Multi harmonic analysis: simultaneous 6-channel harmonic analysis, maximum 50th harmonic measurement, distortion analysis, visual display of total harmonic contents and total contents; Multi frequency measurement: simultaneous 6-channel frequency measurement; Line filtering: 500Hz/5.5kHz low-pass filter to measure the fundamental PWM waveform, filter out the high-frequency interference of the switching power supply current; Sensor: variable ratio, common I-I/V-V voltage/current transformers; I-V type current sensor with BNC interface, maximum input voltage 10V, optional high current sensor; Efficiency calculation: measure the input/output energy consumption of the equipment at the same time, and calculate its efficiency; Accumulation of electric energy: positive electric energy, reverse electric energy and integrated electric energy can be separately accumulated to measure the trading electric energy; Threshold alarm: independent 10 groups of voltage, current, power, power factor and other thresholds and measurement threshold for each channel, automatic upper/lower limit judgment and alarm; Chinese/English interface: Chinese or English operation and time/date display.
The AN87330(F) series high-accuracy power analyzer adopts the latest FPGA+ARM digital processing system to achieve synchronous sampling, which fully meets the testing needs of three-phase equipment in the fields of motors, home appliances, new energy etc. on the market. It is specially designed for production links such as automated line and integrated system etc. Features: High performance, wide frequency band: accuracy up to 0.1%, the bandwidth is DC, 0.5Hz~100kHz, suitable for testing of non-sinusoidal wave load. True differential synchronous conditioning sampling, guaranteeing super large direct test capability, voltage: 0.15~1000V, current: 5mA~50A/1mA~20A. Optional motor torque and speed interface, suitable for testing of three-phase motor mechanical power and energy consumption. Standard RS232, LAN port, standard MODBUS protocol, to meet the customization needs of multiple protocols, optional RS485, GPIB module. Support three-phase interphase angle test. Applications: Dynamic test of brushless DC motor FG signal RMS, peak-peak measurement, duty cycle calculation, wave data analysis. Measurement of RMS and frequency of 3-phase back electromotive force. Phase angle test Power measurement of inverter motor and inverter Power bandwidth DC, 0.5Hz~100kHz Current: 0~20A/current sensor Simultaneously measure input and output power 50th harmonic and distortion analysis Testing of torque/speed of 3-phase motor Support the latest type of motor test module, reserved motor sensor test interface, suitable for signal test of most motor sensor on the market, 3-phase motor efficiency test by single machine, synchronized signal, improved test accuracy.
Purifier and purifier parts Sales & service of over ten years Authorized Agency Mitsubishi Kakoki Kaisha Ltd Bowl Assembly Main seal ring,O-ring Safety Joint,Oil seal and Valve spring 3-way Solenoid valve Solenoid valve Auto Control Device Connecting Tube Friction block,Spring case
Structure Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents. Hermetic compressor Single phase rotary type (mod. 3.5-09) and 3-phase scroll compressor (mod.12-14), with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators. Centrifugal fan Forward centrifugal fans, equipped with single phase direct drive motors, low noise 6 poles, protection level ip54, three speeds Condenser High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material. Evaporator Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins. Desuperheater High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material. (optional) Refrigerant circuit Copper tube connection with charge valve, filter, sight Glass, gas-liquid separator, thermostatic expansion valve, Low pressure switch, high pressure switch The heat pump unit is completed also with 4-way valve, Liquid receiver and one way valve. Hydronic circuit Built with air vent valve, water drain connection, and female-threaded hydraulic connectors. Electric panel Compressor protection; control circuit protection; phase sequence relay (only for 3-phase power supplied; Programmable microprocessor controller (modbus included for bms connection)
blower for range hood, plastic case; electronically capacity control , cable without plug, no lamps
Electric fans and cooling fans.