Piezo siren & alarm, electrical siren.
Smoke detector, fire, CO, gas, heat, water detector.
Fire alarm system, smoke detector, fire detector, CO detector, gas detector, heat detector, water detector.
Piezo sirne, backup alarm, battery backup siren, central door lock.
Smoke alarm.
Conventional and addressable fire alarm systems.
Strobe Light and Horn 1.High alarm sound 100db; 2.Flashing: 2s; 3.Xenon light strobe light; 4.Strobe light and horn; This Strobe Light and Horn is used on fire alarm system. Strobe light and horn features: 1.High alarm sound 100db 2.Flashing: 2s 3.Xenon light strobe light 4.Strobe light and horn. Strobe light and horn Specifications: Operating Voltage: 24VDC Operating Temperature: -10¡ã C to 50¡ã C Operating Humidity: 0 to 95% RH, no condensation or icing Average Current: 70mA Flash Rate: ¡Ü 2 Second Sound Output: ¡Ý130dB Light Output: 1.2W Light Life: >30000 flashes Dimensions (L x W x H): 180 x 130 x 68mm.
Fire alarm bell 1.Base:aluminium 2.Fire alarm bell size:5/6" optional 3.Operating voltage:dc24v 4.High alarm sound Fire alarm bell with good performance from peasway Specifications: 1. Fire alarm bell:aluminium 2. Fire alarm bell size:5/6" optional 3. Operating voltage: 24v dc±15% (no pole) 4. Operating current: 23ma (24v dc) 5. Dimensions: ø127 x 56mm 6. Sound level: >100db (24v dc).
Smoke alarm 1.9V Battery smoke alarm 2.High sound 85dB(3m) smoke alarm 3.Test button 4.Low battery alarm PW-507 Stand-alone photoelectric smoke alarm is under BSI approval, and can be calibrated into either UL, VDS, NF Standards. It features UL-approved Photoelectric sensing components with precise smoke detection. and long life (18 months) 9V battery operation (9V UltralifeLithium battery model for 10-year life is available too). 9V Power Supply, Meets CE, RoHS and EN14604 Specifications/Special Features: Features: Works on principle that infrared scatters on smoke surface Probes smoke which is generated by incomplete combustion at initial stage of fire Smoke detector consists of photoelectric system, signal processing identification and alarm circuit Infrared scatters on surface of smoke when smoke enters darkroom of detector Photoelectric diode receives scattered light and generates photoelectric signal current Photoelectric signal generates alarm signal after being processed by identification circuit, accordingly purpose of alarming is achieved Specifications: Power supply: 9V DC Block battery/PP3 Quiescent current: 8¦ÌA Alarm current:16mA Alarm decibel: ¡Ý85dB/3m Sensitivity standard: EN14604 Age limit of battery: 2 to 5years(It varies with different types of battery) Temperature: -10 to +40 degrees Celsius Low battery Alarm High and stable sensitivity 5 years limited quality guarantee.
CO Alarm 1.Electrochemical CO alarm,Fault signal warning 2.CE ROHS certified CO alarm 3.Test/Hush Button 4.LowBattery alarm. PW-916 Stand-alone CO Alarm from PEASWAY This CO alarm could be one of the most advanced designs in detection Carbon Monoxide .Battery powered models last long life (exceeds 3-year period and up to 5-years), It's the perfect choice for detecting dangerous CO poisoning. Various power input can be manufactured according to customer's special request. 1.CO ALARM Sensor Type: Electrochemical 2. Non-radioactive technology for environmental friendly 3.Power Supply: 4.5V Battery(3*AA) 4.Standby Current: 10uA 5.Alarm Current: 23mA 6.Operation Temperature: 0¡ã- 50¡ã 7.Low battery warning 8.Self-Test Button to verify operation 9.With quick fix mounting bracket for easy installation 10.Silence function with dual led indicator 11.CO Sensitivity meets EN50291 or UL2034 12.Alarm Sound Level: >85dB at 10 feet (3m) 13.Easy to install, move and maintain this co alarm 14.Five years limited warranty for the CO-sensing Operation Temperature 0 oC to 50 oC Response Times At 50 ppm, unit must alarm within 60 ~ 90 mins At 100 ppm, unit must alarm within 10 ~ 40 mins At 300 ppm, unit must alarm within 3 mins Power Source 4.5V BATTERY Standby Current 10uA Alarm Current 23mA Alarm Sound Level 85 decibels at 3 m Detection Type Electrochemical Ambient Humidity 15% to 90% Relative Humidity.
AC powered gas alarm 1.Semiconductor sensor 2.Power Supply: AC110/220 3.Comply EN50194 4.Fault signal, low battery warning, Stand-alone GAS Alarm from PEASAWY.COM 1.Sensor Type: semiconductor sensor 2.Power Supply: 12-24VDC 3.Standby Current: 10uA 4.Alarm Current: 23mA 5.Operation Temperature: 0¡ã- 50¡ã 6.Low battery warning 7.Self-Test Button to verify operation 8.Silence function with dual led indicator 9.Sensitivity meets EN50194 10.Alarm Sound Level: >85dB at 10 feet (3m) 11.Easy to install, move and maintain.
Outdoor siren
Min SPL:115 dB at 12VDC/1m 53.5*29*35.5
China aupax alarm system
SNC-300 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire And high immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
1.Size:160l x 117w x 53h mm 2.Rated voltage:12v/24vdc 3.Rated current:80ma~100ma 4.Flash intensity =1.2ws, flash period1.5s 5.Audio alarm = 95 db 6.Temperature range:-10~+55 7.Humidity range:=95% 8.The life-span of flash lamp?s frequent flashing:=40000 times 9.The product?s index of flash is very great because it adopted the high volume flash lamp from german, it will shape up the effect from vision when input the low volume 10.Three kinds of alarm sound:the ambulance sound, the pumper sound, the police car sound
SNA-360 analogue addressable photoelectric smoke/heat detectors are microprocessor controlled state-of-the-art Detectors compatible with popular control and indicating equipment loop protocols. Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor provide Early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive rate-of-rise Operation or fixed-temperature operation when the response threshold value is exceeded. Photoelectric smoke and heat sensors Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control And indicating equipment, or to addressable fire detection control and indicating equipment that can accept Non-addressable type detectors. An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response Threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation Dual leds for 360° visibility 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions Dip switch address setting 125 usable detector address settings per loop
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting