Fusion splicer, otdr, light source, power meter, tools kit.
All model genset.
PDF Series 300-500W Full brick power supply.Product details are as follows: â?»Features Wide range of input voltage Design for high reliability,long lifetime Under-voltage protection for input Full load efficiency up to 88% High voltage input,high output power Wide range of power,easy toupgrade Conditions:All specifications are tested under the room temperature 25, normal input voltage and pure negative normal load. â?»Input Characteristic Voltage Range 24VDC (Normal Rated Value): 18ï½?36 VDC 48VDC (Normal Rated Value): 36ï½?72 VDC 110VDC (Normal Rated Value): 66ï½?154 VDC 300VDC (Normal Rated Value):200-400 VDC â?»Output Characteristic Voltage set-point accuracy â?¦â?¦±2% Line Regulation (full load) â?¦â?¦±0.5% Load regulation (20%-100%load) â?¦â?¦±0.5% â?»General Characteristic Switching frequency â?¦â?¦â?¦200-350 KHz Isolation resistance â?¦â?¦â?¦200 MΩ â?»Isolation voltage Input-output: >1500 VDC Input-case: >1050 VDC Output-case: >500 VDC â?»Environmental Characteristic Substrate Working Temperature â?¦â?¦â?¦Industry: -40-+100 Storage temperature â?¦â?¦â?¦â?¦â?¦â?¦â?¦â?¦Industry: -45-+105 â?»REM Features Positive Logic:High level or no connect working â?»Dimensions:116.80*61*12.70mm â?»Protection Features Input under voltage protection Output short circuit protection Input over voltage protection Output over current protection Output over voltage protection Over temperature protection â?»Model selection Input Voltage (V) Input Voltage Range (V) Output Voltage (V) Output Current (A) Ripple pk-pk (mv) Efficieency (Typ) Models Single 24 18-36 24 20.8 200 88% PDF500-24S24 48 36-72 24 20.8 200 89% PDF500-48S24 110 66-154 24 20.8 200 89% PDF500-110S24 300 200-400 12 33.3 120 88% PDF400-300S12 300 200-400 24 20.8 200 88% PDF500-300S24 300 200-400 28 17.8 280 88% PDF500-300S28 300 200-400 48 10.4 300 89% PDF500-300S48
Dvp- 730 single fiber fusion splicer Features Color lcd monitor & 256 magnification Compact & light weight Reversible monitor with control panel on each side Max. Wind velocity of 15m/s. 8 sec. Splice time, 40 sec. Tube-heat time Simultaneous x and y views Large capacity internal battery System test ensures the best working condition User programmable Auto check fiber end face Auto calibrate parameters Store 8000 groups of splice results Multiple language options Specifications Applicable fibers smíómmíódsíónz-dsíóedf Cladding diameter 100 to 150um Coating diameter 100 to 1000um Fiber cleaved length 16mm (standard) Splicing mode auto & manual Average splice loss 0.02db(sm)íó0.01db(mm)íó0.04db(ds)íó0.04db(nzds) Return loss í² 60db Environment conditions -25í½ú½50íµ (operation temperature), 0í½95%rh (humidity), 0í½4000m (altitude) Storage environment -40í½ +80íµ (temperature) , 0í½95úÑrh (humidity) Protection sleeve length 20mm íó40mm íó60mm Tension test 2.0n (standard) Language english, chinese, korean, russian, spanish etc. Interface rs232 interface & video output Power supply ac adaptorú¦ 85í½260v input voltage Internal batteryú¦12v voltage, 10ah, up to 150 times of continuous splices and heats Dc adaptorú¦12v voltageú¼optional multipurpose external battery Dimensions 170ú¿wú¬íß140ú¿hú¬íß170ú¿dú¬mm Weight 3.3kg Standard carton
EV charging stations connect an electric vehicle to a source of electricity to recharge electric cars. Usually, there are wall box and stand column versions based on different usage scenarios. provides both versions. We have Mode C version that comes with charging cable and Type1/Type 2 plug at car end, and Mode A version that offers Type 2 outlet at car end. The wall end could be with or without a socket depending on your real needs. We offer basic, app, and RFID options for each Mode, all equipped with Type A 30ma AC + 6ma DC filter protection. The power options are 3.6kW/7.2kW/11kW/22kW. You may customize the cable length, color, logo, the packaging box, sticker, tag or any other related aspects as long as MOQ is reached.
Electric vehicle supply equipment.
Sensor, magnetic sensor, water meter, gas meter, heat meter, energy meter.
Fiber optic, fusion splicer, fiber cleaver, media converter, video converter, OTDR, power meter, laser source, red source, polishing machine, optical equipment, fiber instrument, fiber cable.
1) various kind of permanent manget generators/motor (speed from 30rpm 10000rpm) for wind turbine,hydro turbine system,chp generation,tidal turbine,engine turbine and so on. 2)various kinds of small hydro turbine according water head and flow. 3)horizontal and vertical wind turbine (1 200kw) and inveter,transformers 4)high speed and low speed electrical motors and brushless dc motor..
Semi-enveloped dry type power transformers, srn-M.D underground pattern, kbsg - t mine explosion-proof dry-type transformer.
Transformer.
Transformers and substations.
Power supply, PSU, on board charger, OBC, portable battery charger, EV DC/DC converter, AC/DC converter, DC/DC converter.
Smart insertion working condition flowmeter, smart electromagnetic flowmeter, smart multi hole orifice working condition flowmeter, anti vibration vortex flowmeter,.
Overview Low no-load loss, better quality! Safety 1. Product accepts the NOMEX Paper Insulation System with high level of inflaming retarding, anti-explosion, and fire rating. 2. Professional technology, excellent performance in mechanical strength and short-circuit resistance and long serve time. Reliable 1. H-class heat-resisting temperature: 180¡æ,C-class level for the major insulating material (220¡æ) with efficient overload capacity. 2. Low partial discharge, high level of insulation with long serve time; 3. NBC protection, no crack display. Environmental Friendly Product uses Nomex Paper as the main insulation material, which create fire retardation, high insulation level, low partial discharge, long service life. Transformer Insulation Bass H, main material insulation class C, it increases the overloading capacity. Low noise level and the copper can be recycling after the life cycle of the transformer. Transformer has high capability to resists moisture, dust and salt. Amorphous Core 1) All raw material are supplied by Hitachi Metals with iron loss less than 70-80% of the standard silicon steel. 2) Company has special treatment, procedure and manufacturer process; which has patent number as: 200810238258.6, 20082015857.5, 200820215858.X, 200820215812.8, 200820215814.7. 3) Core structure is dean and strong, which do not influenced by the movement created during transportation. 4) The three column structure has capability to withstand high level harmonics, and vector group can be in Dyn11, Yyn0. Low Voltage Winding features LV uses high quality imported copper foil and class H insulation foil to apply on polyester-imides. In between each layer, it uses Nomex paper. Windings are insulated by vacuum pressure impregnation (VPI) systems, which make it into concrete form. Both ends of the winding drum have applied resin to seal the ends. 1) For better withstand of short circuit capability 2) For better thermo shock resistance and enhance the life expectancy of the transformer 3) Winding has high capability to resists moisture, dust and salt. High voltage winding features HV winding uses several layer coil type with vertical airway structure. It wraps Nomex paper on to copper for insulation. In between each layer, it uses Nomex paper for insulate. Vacuum, pressure, impregnation (VPI system has applied on the coil to make the structure concrete. Both ends are sealed by resin. 1) Multi-layer design can enhance the inrush capability 2) Enhance short circuit capability 3) High insulation level on the insulation material with good airway throughout the coil design, increase the capability of thermo shock. That way the transformer life expectancy is longer. 4) Winding has high capability to resists moisture, dust and salt
Our mature technology has fully considered the various types of high voltage inverter. We carefully developed zpsg dry-type nomex insulation the entire frequency transformers. Our products include 9-pulse, 12-pulse, 18-pulse and 27-pulse, which can be natural or air-cooled type transformer. The transformer is small and has strong overload capacity, low partial discharge, short circuit capability strong, flame retardant, low noise, and with energy saving of up to 40% significant advantages
Multi-layer winding coil Low-voltage coil adopted high quality foil and rolled with the automatic foil machine, argon arc welding with high-accuracy standard; presoak dmd in the interlamination as insulation material. Use presoak glass for insulation both outside and inside, sealed with epoxy resin, followed by solidify in the curing oven, in order to reached the target of high level of humidity resistance. About amorphous metal transformer Amorphous metal transformer introduction The development of the amorphous metal in 1970s, it has been widely used in 1990 for a high energy saving material for the transformer industry. Right now, over one million sets of amorphous metal type transformer had been connected to grid all over the world. The longest proven save and reliable transformer had been running for more than 30 years, and it still perform satisfactory in the power industry. The energy saving is huge and it shall be the new era products in the power industry
Overview High-class security level Sg10 product contains no flammable resin, with no combustion-supporting, no explosion and toxic gas. High-class reliability High-low voltage coil adopted the nomex system, dipping h-class impregnating varnish with vpi vacuum pressure system, and solidify under high heat. Product belongs to h- class(180¡æ), and c-class (220¡æ) for main insulation material, with high- class anti-short circuit capacity. 20% overload is allowed under good ventilation condition. Energy saving & environmental protection Material (copper, steel) recovery afterlife; Burning without toxic chemical substance for nomex paper; Degradation of insulation material, without polluting; Low no-load loss, energy saving; Low noise, flexible design
Low loss, low noise level, high stability This series product possesses four low and one high characteristics which are: low lose. Low noise, low temperature rising.Low partial discharge and high reliability, as well as core-hoisting free and no leakage. With the approval of national transformer quality inspection and testing center. Allthe index of the transformer achieve jb/t3837 standard
Rated Input Current:2mA Rated Output Current:2mA Turns ratio:1000:1 Phase Angle Error:less than 45'(2mA,50) Linear Range:0~1000V 0~10mA(50) Mounting(mm):PCB