Plant physiology instrument, fruit testing instrument, food safety instrument, crop quality instrument, plant protection instrument, soil testing instrument seed testing instrument, agrometeorological instrument, laboratory equipment.
Chemical lab equipment, syring, viscometer and etc..
Clinical diagnostics, LAB consumable like pipette tips (sterile and non sterile) , PCR series, tubes, sealing mats.OEM services
Rapid test for food safety.
HCG pregnancy test kits, LH ovulation test kit, DOA test kits and infecious disease test kits.
Lab analysis instrument, medical analysis instrument, medical supplies.
Laboratory instrument.
Chemical insturments.Manufacture including the package, transportation
Laboratory equipments.
Pipette tips and high molecular filters.
Biological consumables: pcr tubes, cell culture dish, cell culture dish, serological pipette, pipette tip.
Pipette tips, robotic tips, cell culture series, petri dishes, pcr tubes, pcr plate, centrifuge tube.
Description: Orbital Shaker-Incubator is a compact bench top ShakerIncubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program. Seven interchangeable platforms allow it mix and culture samples in flask, petri dish, tubes, Elisa plates, and etc. Built in microprocessor thermo controller provides constant temperature control in the incubator chamber. It is extremely easy to operate, with very straightforward setup of temperature, speed and time. Features: 1.Instantly display operation information(time, temperature and speed) on the LCD screen. 2.Gentle and reliable shaking with direct brushless DC motor. 3.Running safely �¢??-heating and shaking will be automatically stopped once the lid is open. 4.Seven interchangeable platforms can be chosen for variety demands. 5.Auto restart in case of power failure. 6.Over-heating protection device is included. 7.Built-in temperature calibration function. 8.Compact, only 421mmx320mm(DXW) Parameters: Temperature setting range 0C ~60C Temperature control range RT.+5C ~6C Time range 1min ~ 99h59min/ Temp. accuracy �±0.5C(@37C) Display accuracy 0.1C Temp. uniformity �±0.5C(@37C) Shaking range 50~300rpm Orbit 20mm Platform dimension 230x230mm Internal chamber height 182mm Load capacity 4.0kg Heating time �¢?�¤15min(from 25�?�°C to 60�?�°C) Auto resume to run Yes Power 350W Voltage AC220V/50-60HZ Fuse 250V 3A 20 Dimension(mm) 421x320x338 Weight(kg) 18.5 Optional Platforms Type Description PF-1 Platform with clamps for 5 250ml conical flask PF-2 Platform with clamps for 9 100ml conical flask PF-3 Platform with clamps for 10 50ml tube PF-4 Platform with clamps for 18 15ml tube PF-5 Platform with spring holder PF-6 Platform for 4pcs Elisa plates or deep-well plates PF-7 Flat platform for 5pcs petri dishes
Classification: Pipette Brand Name: GEB Model Number: AF250A-9-N-S/AF250A-9-N-S-LB Place of Origin: Zhejiang, China (Mainland) Volume: 170ul Material: natural polypropylene Certificate: CE,ISO14001,ISO14000,ISO13485,ISO9001
Classification: Test Tube Brand Name: GEB Model Number: PC0201-B-N /PC0201-B-N-LB Place of Origin: Zhejiang, China (Mainland) Color: Natural Type: Thin wall, flat cap,Low-Retention Certificate: CE
Quick Details Classification : Pipette Brand Name : GEB Model Number : AT030A-3-N /AT030A-3-N-S/AF030A-3-N-S Place of Origin : Zhejiang, China (Mainland) Volume : 30ul Material : natural polypropylene Certificate: CE,ISO13485,ISO14000,ISO14001,ISO13485,ISO9001 Certified: DNase-Free,RNase-Free,Endotoxin-Safe
Tetracycline residue rapid test device. 40 pcs/kit.
Detection of e. Coli o157 article qualitative detection of colloidal gold feces, food, water and other samples of e. Coli o157. The degree of color is proportional to the sample bacteria. Enrichment effect well. Can be used to treat samples in rapid screening, positive samples can be isolated bacteria, reduce the workload. Steps: 1. Will be placed on the detection of clean, dry working platform. 2. Provided with the kit with clean straw or from the pipette to take samples or enrichment sample 2 drops, drops added to the test sample by adding end section (detection section white side), start timing; 3. 2-15 minutes of observation, 15 minutes after the results do not count. [Results judge] negative: a red line appears, which appears in the control line position of a red line; positive: two red lines appear, that in the test line and control line positions are there red line; invalid: no red line appears that the test line and control line in the position not appear red. [Treatment of samples to be tested] 1. Direct detection: direct detection of water will be. 2. By bacteria detection (1) stool samples: the samples of the inoculated immediately take 1 gram of 9ml of mec broth, 37 constant temperature shaking culture 6h. (2) food samples: the 25 g samples of ground, and immediately inoculated in 225ml of mec broth, 37 constant temperature shaking culture 9h. (3) water samples: water samples will be 400ml immediately inoculated in 5 times concentrated mec 100ml in broth, 37 constant temperature shaking culture 16-20h. 3. Proposed use of enrichment broth was added 20mg / l novobiocin the ec modified broth. [Interpretation of the results] 1. Enrichment after negative results may be judged as negative. 2. Or by direct detection of bacteria have positive results, the pathogen can be isolated. 3. Negative result does not have a precise meaning. [storage] 4-30 , cool dark dry place.
Intended use: Toxoplasma igg/igm rapid test is a rapid immunochromatographic test for the simultaneous detection of igm and igg antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma igg/igm rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of igm anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit igg. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied: 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30 c. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
1. Intended use: The salbutamol residue rapid test card is a rapid, one step test for the qualitative detection of salbutamol in meat samples. The whole time of assay is only approx. 15~25min. 2. Summary: Salbutamol belongs to the group of G-agonists. It can promote animalí»s fat metabollism, and accelerate the growth of animal. However, this is prohibitted. Except for its lipolytic and anabolic effect, salbutamol is used as antiasthmatic and tocolytic agent which has a slacken effect on non-striated musculature. It can remain in animalí»s body and may lead to strong effect to human. If for worse, it may threaten peopleí»s life. Salbutamol is prohibitted for using in most countries. The salbutamol residue rapid test card is a rapid test to qualitatively detect the presence of salbutamol in specimen at the sensitivity of 58g/kg. The major advantage of the one step test device is that the result can be observed easily . 3. Principle: The principle is the antigen-antibody reaction. The one step test device is a competitive immunoassay of which the detector reagent consists colloidal gold particles that is coated with affinity purified anti-salbutamol antibodies. The capture reagent in the assay is salbutamol-protein conjugate, which is immobilised on the membrane of the test device. The specimen migrates over the membrane. The more analyte in the sample, the more effectively it will compete with the salbutamol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent.. If salbutamol in the specimen is above 58g/kg, it will prevent the binding of the detector reagent with the salbutamol immobilised on the membrane, resulting in positive.