Please click here to check who's online and chat with them.

Find Verified X Ray Parts Instruments Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Shanghai  
Jul-19-06
 
X-ray machine
Technical parameter
1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number.
2. The current and voltage of x-ray tubes are fixed in three groups, they are:
X exposure voltageú¿kvpú¬ 60 65 70
X-ray currentú¿maú¬ 0.50 0.85 1.10
3. When adding up voltage, total current is less than 2a and total power is 500w
4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1
5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable.
6ú«wireless remote control in any angles within 10 meters part form the control box
7. The parameter of x-ray generator (bulb tube head)
7.1. The parameter of x-ray tubes
A. Focus index: 0.3í-0.3mm2
Bú«the voltage of the-highest-voltage generator: 90kv
C. The highest inverse peak voltage: 90kv
D. Filament characteristic: vf=5ví+0.5vú¼if=3a
E. Target surface obliquity: 12íp
F. The cooling manner of bulb tube head: oil immersion
8.7.2 the parameter of x-ray generator (bulb tube head):
A. Focus-skin distance: 200mm
B. The thickness of filter-ray film: more than 1.5mmal
C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h)
D. The manner of limiting beam: using planigraphic device
Aug-02-06
 
Technical parameter
1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers.
2. The current and voltage of x-ray tubes are fixed in three groups, they are:
X exposure voltage (kvp) 60 65 70
X-ray current (ma) 0.50 0.85 1.10
3. When adding up voltage, total current is less than 2a and total power is 500w
4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1
5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable.
6. Wireless remote control in any angles within 10 meters part form the control box
7. The parameter of x-ray generator (bulb tube head)
7.1. The parameter of x-ray tubes
A. Focus index: 0.3í-0.3mm2
B. The voltage of the-highest-voltage generator: 90kv
C. The highest inverse peak voltage: 90kv
D. Filament characteristic: vf=5ví+0.5v, if=3a
E. Target surface obliquity: 12íp
F. The cooling manner of bulb tube head: oil immersion
7.2 the parameter of x-ray generator (bulb tube head):
A. Focus-skin distance: 200mm
B. The thickness of filter-ray film: more than 1.5mmal
C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h)
D. The manner of limiting beam: using planigraphic device
May-13-09
Supplier From Foshan, Guangdong, China
 
1) 220V power supply voltage of plus or minus 10% of Pathology
2) Rated 60W.

Technical specifications
Mainframe exterior size 280 * 200 * 80MM
Ball-2009140 * Spiral (excluding Canada longituba)
Weight 2.2kg mainframe
Ball pounds
Temperature 5-40 degrees
Relative Humidity <80%
Exposure time 0.2-0.5S
Set-up time of 0.1-9.9S.
Apr-14-09
 
1. When adding up voltage, total current is less than 2a and total power is 500w;
2. The current and voltage of x-ray tubes are fixed in three groups, they are:

X exposure voltag (kvp) 60 65 70
X-ray current (ma) 0.5 0.85 1.10

3. When adding up voltage, total current is less than 2a and total power is 500w
4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1
5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable.
6. Wireless remote control in any angles within 10 meters part form the control box
7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes
A focus index: 0.3*0.3mm2
B. The voltage of the-highest-voltage generator: 90kv
C. The highest inverse peak voltage: 90kv
D. Filament characteristic: vf=5v+0.5v, f=3a
E. Target surface obliquity: 12
F. The cooling manner of bulb tube head: oil immersion

The parameter of x-ray generator (bulb tube head):

A. Focus-skin distance: 200mm
B.The thickness of filter-ray film: more than 1.5mmal
C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h)
D. The manner of limiting beam: using planigraphic device
Mar-21-23
8 X Ray Parts Instruments Suppliers
Short on time? Let X Ray Parts Instruments sellers contact you.
Dec-24-19
Supplier From Foshan, Cuangdong, China
Jul-14-06
Supplier From Foshan, Guangdong, China
Apr-03-25
Supplier From Foshan, Guangdong, China
See what buyers and suppliers are discussing in X Ray Parts Instruments import export community