Name Testing kit for New coronavirus (2019-nCOV) IgG/IgM antibody Rapid Test WB/S/P Specifications 25 tests Introduce This kit uses the colloidal gold immunochromatographic principle to qualitatively detect novel coronavirus igg/igm antibodies in human serum, plasma, or whole blood. the sample to be tested was added to the sample hole of the test paper, and then added 2 drops of sample diluent. the igg/igm antibody in the sample combined with the recombinant new coronavirus antigen labeled with the colloidal gold on the binding pad formed complex. under the action of chromatography, it diffused forward along the nitrocellulose membrane (nc membrane). the nitrocellulose membrane was fixed with two detection lines (g line, m line) and one quality control line (c line). the g line was fixed with anti-human igg antibody for the detection of new coronavirus igg antibody; the m line was fixed with anti-human igm antibody for the detection of new coronavirus igm antibody; and the c line had quality control for the detection of the new coronavirus ig antibody. If the sample contains a new coronavirus IgG antibody, then the antibody binds to the recombinant new coronavirus antigen labeled with colloidal gold, diffuses forward, and then binds to the anti-human IgG antibody fixed on the NC membrane detection line (G line). if the sample contains a novel coronavirus igm antibody, then the antibody binds to the recombinant new coronavirus antigen labeled with colloidal gold, diffuses forward, and then binds to the anti-human igm antibody fixed on the nc membrane detection line (m line). The darker the color of the colloidal gold accumulated on the detection line, the higher the concentration of the new coronavirus antibody in the sample. To monitor the effectiveness of the test card, set up a quality control line (line C), whether there is a detection line (line T), quality control line (line C) should be color, otherwise the test results are judged invalid.
Name Testing kit for New coronavirus (2019-nCOV) IgG/IgM antibody Rapid Test WB/S/P Specifications 25 tests Introduce This kit uses the colloidal gold immunochromatographic principle to qualitatively detect novel coronavirus igg/igm antibodies in human serum, plasma, or whole blood. the sample to be tested was added to the sample hole of the test paper, and then added 2 drops of sample diluent. the igg/igm antibody in the sample combined with the recombinant new coronavirus antigen labeled with the colloidal gold on the binding pad formed complex. under the action of chromatography, it diffused forward along the nitrocellulose membrane (nc membrane). the nitrocellulose membrane was fixed with two detection lines (g line, m line) and one quality control line (c line). the g line was fixed with anti-human igg antibody for the detection of new coronavirus igg antibody; the m line was fixed with anti-human igm antibody for the detection of new coronavirus igm antibody; and the c line had quality control for the detection of the new coronavirus ig antibody. If the sample contains a new coronavirus IgG antibody, then the antibody binds to the recombinant new coronavirus antigen labeled with colloidal gold, diffuses forward, and then binds to the anti-human IgG antibody fixed on the NC membrane detection line (G line). if the sample contains a novel coronavirus igm antibody, then the antibody binds to the recombinant new coronavirus antigen labeled with colloidal gold, diffuses forward, and then binds to the anti-human igm antibody fixed on the nc membrane detection line (m line). The darker the color of the colloidal gold accumulated on the detection line, the higher the concentration of the new coronavirus antibody in the sample. To monitor the effectiveness of the test card, set up a quality control line (line C), whether there is a detection line (line T), quality control line (line C) should be color, otherwise the test results are judged invalid. Storage Stored at 4 to 30c and valid for 18 months. After the aluminum foil bag is unsealed, please use it as soon as possible. Sample 1. It is suitable for human serum, plasma and whole blood samples. 2. The samples should be used as soon as possible; if they cannot be used immediately, the serum / plasma samples should be kept at 2-8C for 5 days and -20C for long-term preservation; the whole blood samples should be placed at 2-8C to avoid hemolysis; 3.The sample contains a large amount of lipids, hemolysis or turbidity, do not use, so as not to affect the judgment of the results.
Classification: Biological Diagnostics Certification: CE, ISO13485 Food Variety: Liquid Milk( Pasteurized, UTH..), SMP Package/Packing: 96 Test/Box Storage: at 4~30c Shelf Life: 12 Months Pollutant/Test Item: Aflatoxin M1 MRL(Min): 0.5�¼g/Kg Detected Limit : 0.07-0.1�¼g/Kg, 0.3�¼g/Kg, 0.5 �¼g/Kg Usage Mode: Test Strips Form: Strip OEM: Biological Diagnostic Reagents Test Time: 5 Mins Origin: China
Vocom (88890300) is the latest volvo interface for diagnosis & communication with vehicles, including the new euro 6 vehicles range. It can work with the volvo 1998 and older trucks, version2 2002 and newer. It replaces all previous models 88890020 and 88890180. Please noted that the price doesn¡¡£¤t include the activation and update. If activation or update to vtt2.02 needed, charge usd300 for one time. Packing list: 88890300 vocom interface 88890304 obd2 cable 88890306 8-pin cable for european trucks 88890305 usb cable Vtt 2.01 software cd (activation not included)
Dodge Caliber 2007-2011 Focus 2006-2013
5. Voltmeter and Oscilloscope not only communication basis diagnosis (Diagnostic code, ECU data monitor, Active 1) Touchscreen & back lighting control 2) Easy & quick 3) User needn't worry about the after service since factory has an open patio for maintenance. Toyota IT2 Package List: 1. Mainframe -- 1pc 2. OBD-II -- 1pc 3. Charging line -- 1pc 4. Lin line -- 1pc 5. Measuring leads for multimeter 1 -- 1pc 6. Measuring leads for multimeter 2 -- 1pc 7. Card--3pcs(2013.10 toyota, 2013.10 suzuki card and blank card for backup) Toyota IT2 Names of the Parts: The names of the Intelligent Tester II parts are as follows. After Service: .com
Real one-step HIV test kit using saliva, with accuracy 99% and 100% safety, designed for the slightest operatemiss even used by green hands. In the current HIV test market around the world, we can proudly say that we truly provide our respected customers the easiest way of HIV detection, without any pain or danger. Compared with other current HIV tests, it doesnt need to collect blood. Just after a one-step operation, getting a little oral fluid from mouth, the device will automatically finish the rest steps in the developer. Then you can get the result in 15 minutes. Its especially easy operated in HIV self-help screening. The product combines the Natural Short Cavity Sample Collection Technology, colloidal gold-labeled method and sandwich immunochromatography assay. By collecting saliva, it can detect Anti-HIV-1/2 rapidly as a disposable IV diagnostic instrument. It can be used for large population screening conducted by medical institutions and self testing among HIV high-risk group. Standard lot size:15cm x 4cm x2.5cm 25pcs/box.
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: ín1.5 minute per sample Up to 100, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing, block clearing Color lcd display 272mm(l)íß 420mm(w)íß 390mm(h) 24kg
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
Fully automated, compact, flexible and low cost 3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: 60 samples per hour Automatic diluting, lying, mixing, rinsing and clog-clearing Automatic sample probe cleaning Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Reagent expired alarm Color lcd display 40cm(l)40cm(w)46cm(h) 25kg
12 predetermined animals + 4 options, Wbc 3 part diff 19 parameters + 3 histogram 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
80 samples per hour--- Fully auto cap piercing sampler--- Sample rotor valve technology--- Parameters: 19 parameters + 3 histograms Principle: electrical impendence for counting and sft method for hgb Throughput: up to 80 samples per hour Sampler capacity: 50 samples Testing mode: manual open(whole blood, prediluted); sampler close(whole blood) Sample volume: sampler mode: whole blood 200 ª8l Manual mode: whole blood 200ª8l; prediluted 40ª8l Aperture diameter Wbc: 100ª8m Rbc/plt: 80ª8m Memory: 35, 000 results with histogram Performance: Parameters precision cv% Wbc(10 /l) 2.0% Rbc 1.5% Plt 4.0% Mcv(fl) 0.5% Hgb(g/dl) 1.5% Display Large color lcd, displays all parameters result with histogram of wbc, rbc and plt Resolution: 800íß600 Menu Count, sample mode, review, quality control, system setting, reference value, system service, calibration, copyright, shutdown Alert: 25 sets of alert message Input/output: usb(keyboard, mouse, flash disk), rs232, parallel Print:graphic thermal printer with various printing format, optional external printer Operating environment: Temperature: 18-30íµ Humidity: ín70% Power requirement: Ac100-240v, 60/50hz Dimension 600mm(l)íß520mm(w)íß57 0mm(h) Weight 30kg
Nitrofuran (amoz) elisa test kit Technical specifications Sensitivity : 0.1ppb Detection limit: Tissue (some interference in shrimp and fish)--0.3ppb Tissue and honey-0.2ppb Recovery rate Tissue (shrimp and fish)--90+15% Honey , chicken meat /liver-80+15% Cross-reaction rate: Amoz 100% Ahd 0.1% Aoz- t0.1% Sem- t0.1% Weight:1.5kg Dimensions:24cm*16cm*11cm
Chloramphenicol elisa test kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of chloramphenicol in the tissue (chicken, pork), honey, milk, fish, shrimp and egg. The coupling antigen is pre-coated on the micro-well stripes. The chloramphenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against chloramphenicol. After the addition of the enzyme conjugate, the tmb substrate is added for coloration. The optical density (od) value of the testing sample has a negative correlation with the content of chloramphenicol in it. This value is compared to the standard curve and the content of the corresponding chloramphenicol is subsequently obtained. 2. Technical specifications Sensitivity : 0.05ppb Detection limit: Egg, intestine0.1 ppb Honey0.15ppb Milk0.05 ppb Urine and serum0.1 ppb Chicken, pork, fish, shrimp0.05 ppb Recovery rate Chicken, pork, fish, shrimp80%+10% Honey70%+10% Milk85%+15% Cross-reaction rate: Chloramphenicol100% Thiamphenicol
Ractopamine elisa test kit Technical specifications Sensitivity : 0.5 ppb Detection limit Muscle 1ppb Liver--2ppb Urine-1ppb Admixture-25ppb Contrated material , premix material-75ppb Recovery rate Urine--85+10% Muscle and liver--80+10% Cross-reactions Ractopamine---100% Dobutamine-10% Clenbuterol 0.1% Salbutamol -0.1% Weight:1.5kg Dimensions:24cm*16cm*11cm
Honda diagnostic system kit Description: This interface module kit works with the oem-honda diagnostic pc software (hds). It can diagnose all honda and acura vehicle systems on models from 1992 to year 2008, including can-bus system. Functions supported by honda/acura protocols: Reading and decoding fault codes from control blocks' memory; Deleting fault codes; Displays system's current parameters in digital form; Displays system's current parameters in graphical form; Combined displaying of data; Management of executive devices; Logs keeping - writing and keeping of digital parameters in memory; Special functions - changing of permissible settings of blocks, programming etc. Functions supported by obd-ii protocols: Mode 1 - displays system's current parameters in digital form (up to 8 parameters at once); Mode 2 - displays parameters of "freeze" frame; Mode 3 - reading and decoding of fault codes from control block's memory; Mode 4 - deleting of fault codes (memory clearing); Mode 5 - displays results of oxygen sensors; Mode 6 - displays results of changeably controled systems and components; Mode 7 - displays results of constantly controled systems and components; Mode 8 - management of executive devices; Mode 9 - displays car's identification info. Hardware and software requirements: Pc or laptop with either windows 2000 professional (sp4 or later) or xp (sp1 or later) Hard disk drive with at least 400mb of free space Cd-rom drive (if a high-speed internet connection is not available) Rs232 port required to connect pc to him (pc version software only) Monitor capable of displaying in vga mode or above (1024 x 768 recommended) Internet connection (high-speed connection recommended) Honda diagnostic system kit includes: 1 x him with obd ii cable 1 x dvd 1 x 3 pin cable 1 x rs232 cable 2 x selftest adapter 1 x storage case Net weight: 3.5kg
Features: 1) wonderful gift imagined and designed for pregnant women to listen to heartbeat and movements of prenatal babies 2) prenatal babies' activity can be heard from the twelfth week of pregnancy with the sounds of hiccups, kicks, blows and heartbeats 3) thanks to the cable of recording, you will be able to record those first sounds for life. It not only can be recorded by the computer, but also cassette or cd 4) enjoy a first private communication with your baby and make a souveniror his growing up. E-mail the first sounds to your family and friends who are not at your side but want to share the happiness together 5) like a family doctor, it can help you keep the prenatal babies' health by detecting heartbeat rate three times per day Outer packing: 30 sets/ctn
Features: Print out fhr & toco curve recording. "y" connection of two probes and remote maker, avoid twisting. Regarding technical specification or more products. Please visited our website. Jpd-300p lcd display Ultrasound frequency 2.2 mhz Ultrasound intensity
Diagnostic tool Features Universal dash programmer is the most sold programming-device for digital speedometers worldwide. The system is a high-quality tool, which offers a maximum of flexibility and working comfort despite simplest operation. You can serve almost any vehicle with the tacho universal. Specification Outstanding characteristics of our programming system are: 1.The current odometer reading is decoded and shown in the lcd display 2.Easy self explanitory operation by clear menu guidance 3.Backlit display makes working possible in overcast conditions 4.All datasets can be edited, saved and loaded 5.The stored data can be transferred to a pc for archiving 6.Up to 200 files can be stored in the universal dash programmer 7.Broken speedometers can be repaired comfortably 8.You receive further developed software from us by internet 9.New types and manufacturers can be released within seconds by telephone. There is no need to send the unit to us.
Lcd displays fhr (jpd-200c) One hand operating of on/off, volume up/down. One plug with two probes can be switched easily(optional) Standard accessories Ultrasound probe 2.2mhz Ac/dc adapter Automatic charging stand Battery (fixed in)