FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: 32mm Ratio ranging from 60/1A to 600/5A CE, UL PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1%/60Hz System Voltage 720V(0.72kV) Output signal 1A or 5A 333mV AC or 100mV-2V optional Burden 2.5VA Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Max. jaw opening 32 mm Mechanical parameters Dimensions (DH) (mm) 110mm130mm 41mm Weight(g) 700 Operating conditions Operating temperature -25 C to +55 C Relative Humidity 0-85% non-condensing Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 30-1000A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 45x120x65 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Accuracy Class 0.5%, 1% Range of primary rated current 300-3000A Range of Rated load 25VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 300-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 50x110x32 Weight (kg) 1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 20-600A Rated load 25VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FSâ?¤10 Mechanical parameters Dimensions (WDH) (mm) 50x110x105 Weight (kg) 3.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load 10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 150%I1n Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids. Accuracy 0.02% Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery Output voltage 0-100Vrms Output current 0-5Arms (20A peak-value) Output power 0-400 VA (1500 VApeak) Automatic frequency variation range 0.1-60Hz Equivalent excitation voltage â?¤5000V/50KV Accuracy â?¤0.5% Secondary winding DC resistance measurement Range 0.1-1000�© Accuracy â?¤0.05% Secondary actual load measurement Range 5VA-1000VA Accuracy â?¤0.5%�±0.1VA PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed) Resolution 0.1min PT ratio error measurement Range 1-15000 Accuracy 0.05% LCD display 7' inch TFT touch color LCD Communication port USB port Printer Yes, Thermal printer
GF1061R portable instrument transformer turns ratio test set is mainly used for field or lab testing of current transformers and voltage transformers, it can fully automatic test CT and PT turns ratio. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. Test quickly, operation simply Environmental conditions Accuracy 0.05% Power supply AC 220V±10% or AC 120V±10%, 50/60Hz Voltage Range 0-100Vrms Resolution 0.1V Current Range 0-500mA Current accuracy ±1mA, ±0.05% of reading ±1 digit CT PT Turns ratio CT 0.8-50000; PT 0.8-10000 CT PT turns ratio Accuracy ±0.05% Phase angle measurement 0-90
Features: High saturate magnetic induction bs High initial permeabilityhigh linearity high accuracylow phase and amplitude error for ct Good temperature stability-55~130 Applying for transformer class grade: 0.5-0.05 class 2applications High precision current and voltage transformer Current leakage circuit breakers Electronic watt hour meter Precision power meter Current control in automation industry
1.Features, High permeability High saturation induction , low core loss The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the Two. It is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. Good temperature stability:work for a long time at temperature of -55 ~ 130 , The linear range of nano-crystalline alloy is wider than that of permalloy .
Air sepreration, Air compressor, PSA oxygen generator, PSA nitrogen generator, mobile nitrogen plant, mobile oxygen plant, vacuum furnace,, metal materials, vacuum heating furnace, vacuum brazing furnace, lab atmosphere furnace.
DC, DC converters, DC, AC inverters, AC, DC converters, transformers, electronic ballasts.
Machines, equipment, device, supplies, valves, generator, meter, ecg, medical, mechanical.
Traffic goods, road studs, glass beads, reflector film and traffic sign, oxygen generator.
Elisa kits, clia kits, hematology analyzer, oximeter.
Cores, amorphous cores, nanocrystalline cores, permalloy cores, NI-FE cores, transformer cores.
Grid-tied inverters, PV generation system.
The model Q8A1 current probe/clamp on ct is based on AC transformer technology for use in measurement of AC current, it is suitable for 5A, 10A cable online measurement. With measurement range of 1 mA to 10A AC and frequency range from 40Hz to 200KHz, it has a high accuracy class of 0.1%. It suits for oscilloscope, power quality analyzer, electric energy meter calibrator. Easy to operate everywhere. its technical standard according to EN 61010-1, EN 61010-2-032, IEC60044-1. This model Q8A1 clamp on current probe have been used in many instrument manufacturers. FEATURES
The P110 clamp current transformer is a high performance AC Clamp current probe with excellent transformation and low phase shift. The high quality magnetic permalloy core and uniform windings provide for accurate measurements up to 1000AAC/250AAC/600AAC. The ring type jaw permits good magnetic conduction and cable positionings. Provide excellent RMS capabilities and reliable signal reproduction. FEATURES
Inverters, batteries and PV system.Transportation