Instrument transformer.
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Current transformer, voltage transformer, fault indicator, power distribution equipment.
Sbh16-m.D amorphous alloy submersible transformer
Sc(b)h15 amorphous alloy dry-type distribution transformer Transformer can be installed indoors deep into the load center, so as to adapt to the need of high-density load of big modern cities. With the no-load loss reducing by 75% and the load loss reducing by 15% than that of gb/t10228 table 4 group i, the amorphous alloy distribution transformer is the state of the art energy efficient dry type transformer
Ac machine, ac service station, ac r134a refrigerant flush machine, recycling recharging recovery, ac refrigerant recycle recharge recovery machine, ac recovery machine, ac recharge machine, ac service machine, wholesale ac service station, manufacture ac service station.
-SMD IFT coils for TV receivers and AM and FM radios -Variable inductor and coils with wide range of inductance -Designed for application in different types of circuits -IFT coils with internal capacitors -SMD IFT coils for radio receivers and AM and FM radios -IFT variable coils for wireless communication system and remotecontrol toy/equipment -IFT adjustable coils with wide range of inductance -Designed for application in different types of circuits -IFT coils with internal capacitors -EC, EE.EI and PQ type high frequency switch transformer EP type magnet shielding switch transformer -RM type communication filter, aux power transformer -ET, FT type linearity G (jar shape) switch transformer -DR (I) type transformer T (ring) iron power core, DC filter inductorRM series: RM-4, 5, 6, 8, 10, 12, 14 ISO UL Certification, Welcome Custom Common mode choke Electric choke coil Two ring core spider web coil Features: Vertical base-mounted Low cost and high current Closed magnetic circuit for lowest EMI Original manufacturer ISO 9001:2008 With UL qualification Keeps 4â?° disqualification rate 3-5pcs free samples Short lead time 100% test before shipping International standard specification Professional packing 300K per month Conform to CE, RoHS, FCC OEM/ODM accepted Applications: Copying machine, display monitor, ADSL modem, gaming machine, color TV, video camera, air conditioner, refrigerator, laundry machine, microwave oven and car electronics
Ef type high frequency transformer -smd ift coils for tv receivers and am and fm radios -variable inductor and coils with wide range of inductance -designed for application in different types of circuits -ift coils with internal capacitors -smd ift coils for radio receivers and am and fm radios -ift variable coils for wireless communication system and remotecontrol toy/equipment -ift adjustable coils with wide range of inductance -designed for application in different types of circuits -ift coils with internal capacitors -ec, ee.Ei and pq type high frequency switch transformer ep type magnet shielding switch transformer -rm type communication filter, aux power transformer -et, ft type linearity g (jar shape) switch transformer -dr (i) type transformer t (ring) iron power core, dc filter inductorrm series: rm-4, 5, 6, 8, 10, 12, 14 Iso ul certification, Welcome custom Company with ul qualification Original manufacturer Iso 9001:2008 3-5pcs free samples Short lead time 100% test before shipping International standard specification Professional packing 300k per month Conform to ce, rohs, fcc Oem/odm accepted
Features .High initial permeability and high AL value .High effective insertion loss and excellent noise suppression .Wide frequency range,large adjustable range for permeability from 20000-160000 .Low core loss, small choke size for volume and wieght with epoxy coating Application: .Switched-mode Power supplies .EMI common mode filter
Features: DC current immunity composite cores is combined with amorphous and nanocrystalline cores together Magnetic features: . Strong anti-DC-capacity . Precision, the scope of application of 0.5-0.1 grade and applicable Current range 1.5-200A . Good temperature stability Applications: .DC current immunity transformers .Metering transformer in electronic power system
Features: The adjustable range of permeability Excellent frequency characteristics High saturation magnetic induction strength Lower eddy current losses Excellent temperature stability Applications: Switching Mode Power Supply UPS Uninterrupted power supply Pulse welding equipment Power converter
Strange dc current immunity applicable current range (1.5a-200a) High linearity, high accuracy class, applicable transformer accuracy range 0.5-0.1 class Good temperature stability Core size saving by volume and weight Applications: .DC current immunity transformers in electronic energy meter/watt-hour meter .Metering transformer in electronic power system
Ratio 2500: 1, 2000:1 or 1000:1 (customized) Accuracy class 0.2%, 0.5% Phase shift
Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.2%, 0.5%, 1% Primary current 0 - 3000A AC Secondary current 0 - 5A AC (customized) Max. Cont. Input current 3600A Over voltage category CAT III 600V Output signal (AC current) 500mA,1A,2A,5A AC at nominal input current Output signal (AC voltage) 333mV, 500mV, 1V, 5V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output (2.5m) Mechanical parameters Dimensions (L x W x H)(mm) 180 x 319 x 35 Weight (g) 1100 Holding wire diameter (mm) 125 Max. jaw opening (mm) 125 Color Black Material PC+ABS+Polycarbonate, UL94 V0
Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.2%, 0.5%, 1% Primary current 0 - 3000A AC Secondary current 0 - 5A AC (customized) Max. Cont. Input current 3600A Over voltage category CAT III 600 V Output signal (AC current) 500mA,1A,5A AC at nominal input current Output signal (AC voltage) 333mV,500mV,1V,5V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 116 x 327 x 35 Weight (g) 1200 Holding wire diameter (mm) 120 x 50 Max. jaw opening (mm) 50 Jaw Color White Material PC+ABS+Polycarbonate, UL94 V0
WIRING DIAGRAMS Split core cast resin current transformer P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal. P2, S2 is homonymous terminals (subtractive polarity). PARAMETERS Technical parametersã?? Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 30-1000A Rated load â?¤30VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 6015560 Weight (kg) 3.6 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: �?16mm Measurement range of 1mA to 200A AC Low phase shift for power measurement Output model: Lead output(2.5m) Isolated plastic case recognized according to UL94-V0 Small-size, compact size, light-weight Over-Voltage protection circuit is installed. CE, UL / EN 61010 - 1 certified PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 1000: 1 or 2000:1 , customized Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1% System Voltage 720V(0.72kV) Output signal 10mA-200mA AC optional 333mV AC or 100mV-2V optional Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Protection Level 3.0V0-P Installation Category CAT or CAT 600VAC Max. jaw opening 16 mm Mechanical parameters Dimensions (WDH) (mm) 38mm 55mm 18mm Weight(g) 60 Operating conditions Operating temperature -25C to +55C Relative Humidity 0-85% non-condensing Altitude
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 100-1500A Rated load â?¤10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 80x110x50 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 20-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 18 130 55 Weight (kg) 2.3 Operating conditions Operating temperature -35C to +55C Daily average temp