PE coil pipes and tubes for water and wire cable conduit PL231
The PE coil pipes and tubes can be used:
water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm
pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm
weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm
We use new 100% pure raw PE material
WHY NEW MATERIAL HDPE PIPES?
1. Health performance
PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria.
2. Corrosion resistance
It can resist various chemical media erosion, with no electrochemical corrosion.
3. Service life
Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years.
4. Impact resistance
PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break.
5. Connection performance
The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load.
6. Construction performance
It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
Specifications:
Nylon
Meets UL-94HB Flammability Rating
Color: Black .
Temp Range: -40C to 150C.
Features:
Split design for easier installation and removal of wiring
Cable protection for electrical wiring harnesses
Flexible body facilitates your corner/elbow wiring
Heat resistance :-25 - +75
Properties:PVC spiral hose with unbreakable core inside,long-lasting.Smooth wall inside.Different colors can be prdered.RoHs approval.
Usage:For water,liquid,powder,granule transmission.Water supply drainage usage in construction etc.
Available for 150 Series,160 Series,171-180 Series.
Specification OD (mm) ID (mm) M/Roll
16 15.6 12 20
20 20.5 16 20
25 26.2 22 20
32 33.2 28 20
40 40 35 20
Nylon
Meets UL-94HB Flammability Rating
Color: Black .
Temp Range: -40�°C to 150�°C.
Features:
Split design for easier installation and removal of wiring
Cable protection for electrical wiring harnesses
Flexible body facilitates your corner/elbow wiring
EVT threaded conduit body for rigid conduit or IMC allows access for general inspection, maintenance and wire pulling. Conduit body saves time and money by eliminating costly bending of large conduits in order to change the directions of conduit runs. Its powder-coated finish and neoprene gasket ensure a weatherproof installation.
EMT is short for Electrical Metallic Tubing. EMT tube, also commonly called thin-wall, is a steel raceway of circular cross section, which is unthreaded, and nominally 10² long. EVT EMT conduit is UL listed with UL file number E476073. EMT electrical is manufactured according to UL 797, CSA C22.2 NO.83.1 and ANSI C80.3, Electrical Metallic Tubing â?? Steel.
EMT Tubing is available in trade sizes 1/2 through 4. The steel conduit is galvanized both inside and outside for corrosion protection. EMT pipe is commonly installed by use of set-screw or compression type connectors and couplings.
Galvanized steel, square-locked core with cord packing from 3/8" to 1-1/4", interlocked core from 1-1/2" to 4" to give additional strength to prevent unravelling
Smooth wipe clean PVC jacketed
Liquid-tight IP66/IP67
Good flexibility
High mechanical strength
Flame retardant
UV protection
moisture proof
Resistance to most of chemicals, such as oil, acids and vapors, etc.
Good Absorption of motion and vibration
Cover does not winkle when bent
Temperature range from -20oC to +105oC
PVC color black (standard), grey or orange (made to order)
Nickel plated brass fittings
Galvanized malleable iron fittings
Stainless steel fittings
Applications:
General industrial installations and wire protection
Outdoor installation
Machine tools
Installations where liquid-tight is a requirement
Special Applications:
According to customer's samples and specifications, we can manufacture the LT type flexible conduit to suit special applications, such as wider temperature range, specific chemical resistance, etc.
Galvanized steel core, Plastic jacketed.
Light weight style, excellant flexibility and low fire hazard low smoke.
Use for the place with poor ventilation or the environment needs more secure care or any narrow space for electrical wiring application.
Temperature range from -10oC to +90oC
Applications:
General indutrial installations and wire protection
Outdoor installation
Machine tools
Features:
Galvanized steel, square-locked core
PVC vacuum jacketed
Light weight
Water resistance
Excellent flexibility
Temperature range from -20oC to +105oC
PVC color black (standard), grey or orange (made to order)
Nickel plated brass fittings
Galvanized malleable iron fittings
Stainless steel fittings
Applications:
General industrial and commercial electrical wiring protection
Machining centers and robotics
any narrow space in static applications
Special Applications:
According to customer's samples and specifications, we can manufacture the VJ type flexible conduit to suit special applications, such as wider temperature range, flame retardant, etc.
Structure:
Connector body with hexagonal wrench surface, thread ISO metric in accordance with EN60423 or thread NPT in accordance with ANS/ASME B1.20.1-1983, Comply with stands AS/NZS 2053. 8, hexagonal pressure nut, sealing ring and ferrule
Material:
Connector body - Galvanized die casting, zinc plated steel& malleable ironï¼? nickel plated brass, stainless steel.
Hexagon pressure nut - Galvanized die casting zinc plated steel& malleable iron, nickel plated brass, stainless steel.
Sealing ring - Nylon 66
Ferrule - Galvanized steel
Features:
Simple, one piece installation provides a quick and reliable liquid-tight seal
IP rating from IP40 to IP66/67/68 in combination with the corresponding flexible conduits
High mechanical strength
Highly liquid-tight and dustproof
Vibration and tension proof
Inherently low fire hazard
Covering of the conduit ends
Available in straight, 45o and 90o bodies
Available in ISO Metric and NPT, PF, PG, BSP etc. threads
Applications:
General industrial and commercial electrical wiring protection
Machining centers and robotics
any narrow space in static applications
General wiring for OEM applications
Low fire hazard applications
Under flooring wiring in office buildings
Machine tools
Installations where liquid-tight is a requirement
Outdoor installation
Special Applications:
According to customer's samples and specifications, we can manufacture special fittings for suit any type of flexible conduit applications.
Specifications:
5/16"-2"
Suitable flexible conduits:
VJ type of vacuum jacketed flexible conduit
LT type of liquid-tight flexible conduit
FM type of flexible metallic conduit
309 Electric Conduits Suppliers
Short on time? Let Electric Conduits sellers contact you.