Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs. High temperature resistant liquid-immersed transformer 10kv 30kva-3150kva 35kv 50kva-31500kva
Transformer bobbins Injected phenolic material and inserted pins 39x34x29cm about 9kgs
Transformer bobbins Made from Phenolic, PBT, Rynite or Nylin
Metal, spark analyser, spectro, model spectrolab M, type lavmal 8A, with konstanter transformer.
We are regular suppliers for all kind of plastic and metal and we ship to any destination port worldwide on CIF basis. interested buyers should contact us for more details and quotes
Have four number 33 kva used transformer to sell in working condition. Crompton Greaves, India, 1995 model.
A transformer is an electrical device which is used to transfer power from one circuit to another through electromagnetic induction. The power transfer is accompanied without frequency change. In an electronic system, the term power transformer is used to provide a number of AC supplies of several voltages and appropriate values of current from the public electricity supply. Tungwell oil immersed transformers are up to 750kV, 1500MVA and cast resindry type transformers are up to 110kV, 40MVA. Our design team has very strong design capabilities and uses a variety of design software including 2D and 3D electrical field FEM and Magnetic flux leakage calculators. The resulting products come with many advanced features such as low loss design, short circuit withstand assurance, reliable extra-high voltage protection with overheating controls. The range of small power transformers can be from500-7500kVA The range of medium power transformers can be from-100MVA The range of large power transformers can be from100MVA & beyond
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
1. Inverter duty Solar transformers, suitable for solar load profile. 2. Multi-winding (2 to 6 windings), oil-filled or dry type. 3. 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV. 4. Low-loss, with Aluminum or Copper winding. 5. Electrostatic shield between LV and MV Winding. 6. Fully type tested at internationally recognized laboratory. 7. Designed with high efficiency, environmental friendliness, superior operational reliability and minimal Total Cost of Ownership. 8. Ideally suited for large MW scale solar PV plants.
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10
2450Kva threee phase dry type transformer Our products got certificate of ISO9001,ISO14001 and OHSAS18001. And 18 low voltage products get national certificate of CCC. Also our products get quality testing report from China Quality Certification Center(CQC). Our customers include urban distribution network, power station, transformer substation, oil, chemical, railway and big construction companies. And products export to America, Brazil, Peru, Kenya, Ethiopia, India, Myanmar, Vietnam etc. We sincerely welcome all friends from domestic and overseas to come to cooperate and develop together.
All types of DB's available
outdoor / indoor Transformer Available
Product description This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc. Technical index Temperature control: a. Chromatographic column chamber temperature a.1 Temperature control range: room temperature +8 400(Set the temperature increment 1) a.2 The precision of temperature control: It is±0.1, which is below 200;
110ACV to 12ACV 220-250ACV TO 12ACV US/EUR/AUS three standard products MOQ:100 EA Package: carton
EE30 horizontal 6+6pin customer transformers.
Trutech Products owns the vast industry experience and well-aware of the need of todays society. We are engaged in designing and manufacturing a wide range of transformers including Control, Step-down, Three-phase, Isolation, Special Purpose, Auto Transformer, etc. Our models are distinguished from one another in size, shape and volt rating to work on different applications and industries. Backed by a talented and experienced team of engineers, we have always delivered up-to-the mark solution to our clients that fit into their budget and deliver them guaranteed results. Being the most progressive Transformer Manufacturers in India, we make sure to perform all the quality tests before performing all the safety and standard test before sending it for the shipment. Our transformers are highly demanded in commercial as well as industrial sectors. If you want the same or look for some more details, be in touch with our customer executives that answer all your queries and guide you the right solution that matches your requirements.
Product description: standard current transformer is used as a standard for calibrating current transformers, Used as a standard to calibrate current transformer whose accuracy class is two or more lower than itself. The grounding pole of the machine shell must be grounded. To avoid electric shock, the conductor must be connected to the ground Technical index 1. Temperature: -5-40 2. Relative humidity: 80% 3. Allow long-term work under the rated current; More than 600A across the core. Feature; 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.