Bypass Switches
Available Brands : Schneider, Siemens, ABB, Legrand, C&S, Eaton, Larsen & Toubro, Havells, Indoasian
# By Pass Switch # Panel # Bypass Switches # Saudi Arabia # Oman # Qatar # Yemen # Dubai # Electricals # Electric
Switch Rail Clamp Scope of use of portable hook lock: 1. Lock switch when repairing switch signal switch machine. 2. Lock the switch when passing the special train. 3. When temporary power failure occurs, the train runs and locks the switch. 4. Closed special line lock special line turnout. 5. Line new switch lock new open switch open. 6. Lock the switch during the construction of the special line. Specification Model LJ-GSQ Type Switch Rail Clamp Material Stainless Steel Dimensions (L x W x H) (40*15cm Weight 2kg
Temperature rise test panel for domestic switch Specifications Input supply : 230v ac + / - 10% , 50 hz single phase with mcb protection. Output : current source 0 to 50 a max Digital voltmeter : 3-1/2 digit 0 to 300v Voltage drop indicator with range selector. Digital temperature indicator with 12 channels. Current controller for maintaining the output current at pre-set value. Ct range selector for accurate measurements. Description The test panel is made to suit the specification as mentioned in is : 3854 of 1997 for temperature rise test. The test panel broadly comprises of : 1. Ac constant current source ( true rms ) for 50 amps max / 5v. 2. Universal servo controller, for controlling the output current with the help of motorised variac Assembly. 3. Digital ac voltmeter to read the primary voltage of the power transformer. It helps to eliminate the Possibility of hunting of motor with the help of primary tap selector switch. 4. Digital temperature indicator controller - 12 channels - with thermocouples, to read the temperature rise At different parts of the switches. 5. Digital ac voltmeter with terminals and three ranges - 0.2, 2.0 & 20 v to measure the voltage drop Across the switch terminals while passing the specific current. 6. Range selector switch for ct to measure more accurately the current for lower as well as higher range. 7. Push buttons for test on / off with output indicating lamps. 8. Mains on mcb 2p / 10 a.
Switch Our products are widely appliable to the fields covering main board telecommunication, broadcast television, automation equipment, software, interphone, lighting, relay, electric motor car with high performance.And the company has passed through iso9001quality authentication, ce and other international safety certification. Ic tube packing
This is an intelligent hdmi 5x1 amplifier switcher. It allows five hdmi source devices switched into one hd monitor or projector. Adopted touch button design let you enjoy the high technology and easy switching life. Quite differ with other switchers, this intelligent switcher has one input port on the front panel. This not only reduced the switcher to an ideal small size but also be more convenient for users to connect the source devices. Features This hdmi amplifier switcher has many features that enable it to perform in a superior manner. Among those features you will find: 1.Multi-witching methods: intelligent, ir remote or by touch button 2.Supports hdmi1.3b 3.Supports highest video resolution 1080p. 4.Supports 250mhz/2.5gbps per channel (7.5gbps all channel) bandwidth. 5.Supports 12bit per channel (36bit all channel) deep color. 6.Hdcp pass-through. 7.Supports uncompressed audio such as lpcm. 8.Supports compressed audio such as dts digital.
Load Change Over Switch ATS Power Switch for Generators Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. RDS2 series Auto changeover switch mainly used for distribution or electromotor network under 50Hz, rated voltage 380V, rated DC voltage 220V, and rated current 16A to 3200A, change over between main power and backup power, mutual work as backup power system and city power and Generator power. At the same time, it can act as disconnector for the un-frequency ON and OFF circuit or lines. Such product are widely used in the power transmission and distribution system and atomization system of important site which power off is not allowed, such as fire-fighting, hospital, bank, high buildings etc. RDS2 Auto Transfer Switch Equipment (ATSE), is integrate the switch and logical control together, no need extra controller, is an electromechanical integration auto transfer switch, with voltage monitoring, frequency monitoring, communication port, electrical and mechanical interlock functions etc., can achieve auto control, remote motor control and emergency manual control. Operation is achieve by logical control board with various logical commands to managing the motor, gear-box running, motor with spring energy storage, instant release accelerating mechanism, quickly open and close the circuit or make quick transferring, through visible status to make sure the safety isolation, greatly improved the every electrical and mechanical performance. RDS2 ATS integral designed with metal case, compact and strong. RDS2 ATS, the control part is with metal cover, switch part with DMC case, have strong dielectric performance, protection performance and reliable operation safety. The switch suitable for auto transfer between main power and backup power system or two load equipment's auto transfer and safe isolation etc. The switch has beautiful appearance, novelty, small size, complete functions, is the best choose among the similar products. RDS2 series product have passed the EMC test.
Load Change Over Switch ATS Power Switch for Generators Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. RDS2 series Auto changeover switch mainly used for distribution or electromotor network under 50Hz, rated voltage 380V, rated DC voltage 220V, and rated current 16A to 3200A, change over between main power and backup power, mutual work as backup power system and city power and Generator power. At the same time, it can act as disconnector for the un-frequency ON and OFF circuit or lines. Such product are widely used in the power transmission and distribution system and atomization system of important site which power off is not allowed, such as fire-fighting, hospital, bank, high buildings etc. RDS2 Auto Transfer Switch Equipment (ATSE), is integrate the switch and logical control together, no need extra controller, is an electromechanical integration auto transfer switch, with voltage monitoring, frequency monitoring, communication port, electrical and mechanical interlock functions etc., can achieve auto control, remote motor control and emergency manual control. Operation is achieve by logical control board with various logical commands to managing the motor, gear-box running, motor with spring energy storage, instant release accelerating mechanism, quickly open and close the circuit or make quick transferring, through visible status to make sure the safety isolation, greatly improved the every electrical and mechanical performance. RDS2 ATS integral designed with metal case, compact and strong. RDS2 ATS, the control part is with metal cover, switch part with DMC case, have strong dielectric performance, protection performance and reliable operation safety. The switch suitable for auto transfer between main power and backup power system or two load equipment's auto transfer and safe isolation etc. The switch has beautiful appearance, novelty, small size, complete functions, is the best choose among the similar products. RDS2 series product have passed the EMC test.
Generator Load Transfer Switch ATS for Diesel Generators Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. RDQ3NM Series Advantages: 1. There is a reliable mechanical interlock device and electric interlock protection between two MCCB, completely avoid the possibility of two MCCB closed at same time; 2. Intelligentized controller adopt the single chip microcomputer (SCM) as the control core, simple hardware, strong functions, easy extension, high reliability; 3. Intelligent controller circuit layout design adopt power sampling separate with SCM control, from the hardware to overcome the electromagnetic interference; 4. With short circuit, over load protection functions, over-volt & under-volt,phase missing auto transfer function and intelligent alarm function; 5. Auto transfer data by external setting freely, with operation motor protect function; 6. Signal connecting cable have passed FLUKE instrument channel test, anti near crosstalk,attenuation crosstalk and back wave loss, can meet the test criteria for permanent link; 7. The ATS controller installation method provide customer with highly autonomy, ( split installation only need simply connect the attached RJ45 signal cable to the corresponding terminal port);
HTFuture dual fiber Fiber Media Converter (Electric To Optic Converter) is designed to convert data signal between 10/100 Base-TX and 100 Base-FX fast Ethernet. The media converter is connected between Fiber cable and Twisted cable segments with network operating smoothly. The Ethernet transmission distance of 100 meters from copper extended to 2 km (multimode fiber) or 120 km (single mode fiber). Using sophisticated switching core, support hot-swappable, with flexible, efficient, reliable etc. It's widely used in Telecommunications, Broadcasting, Broadband networks, Million high-definition video surveillance ect where require high-performance, high-reliability network environment. Features 1, 10M/100M Adaptive, full/half duplex automatically configure in TP port. 2, The Max transmission distance: Mulit-mode 2KM,Single mode 120KM. 3, Using sophisticated switching core and ?large capacity of cache. 4, Supports LFP(Link Fault Pass-Through), Broadcast storm protection, Balanced Traffic, Isolate conflicts and Detection error. 5, Compliant with IEEE802.3 10Base-T and IEEE802.3u 100Base-TX,100Base-FX Standards. 6, High-quality laser device has good optical properties, electrical properties and temperature stability. 7, Science Circuit layout , anti-interference ability, can effectively prevent lightning. 8, Working status indicator is complete, which can easily manage devices. 9, External professional switching power supply, security and stability. Power consumption is less than 4W. 10, Built-in lightning protection circuit, greatly reduce the damage caused by lightning induction.
Supplier: Cctv ip camera, em lock ,nvr ,dvr ,cctv camera fire extinguisher, door interlocking system ,pass boss controller ,magnetic lock ,air shower controller, door exit push switch