FDR-3001 Sulfur content of petroleum products tester (lamp method)
Scope
Standard: ASTM D1266
Sulfur content of petroleum products tester (lamp method) is the People's Republic of China in accordance with the requirements of standard GB/T380 "Determination of sulfur content in petroleum products (lamp method)" under the design and manufacture of this instrument is suitable according to GB/T380 standard The method of measurement prescribed Reid vapor pressure not greater than 600 mm Hg light petroleum products (gasoline and kerosene) of sulfur content.
Features
1, glassware easy loading and unloading.
2, the combustion lamp can be adjusted up or down according to need.
3, the gas flow rate of each gas path can be adjusted independently.
4, can be sucked sample gas after combustion, while stirring the test solution from the dual role.
Technical Parameters
1 Power supply: AC220V ± 10%; 50Hz.
2, the number of samples: independent five groups, each group can test separately.
3, electromagnetic pump: master electromagnetic pump independent five groups vacuum exhaust volume can be adjusted independently, auxiliary electromagnetic pump (mixing pump) a group.
4, vacuum extraction adjustment: stepless adjustment potentiometer.
5, Enlightening regulation: EEP each group can be independently adjusted up and down to adjust the range of not less than 15 mm.
6, structural materials: countertops and stainless steel tube holder.
7, cuvette holders: each group independently adjustable cuvette holder, adjustable range of not less than 20 mm.
8, the ambient temperature: -10 ~ 40 .
9, relative humidity: 85%
10. Power consumption: less than 150W
Scope According to the people's republic of china national standard gb / t 1792 requirements "mercaptan sulfur distillate fuels assay (potentiometric titration)" under the design and manufacture suitable for measuring the content is within 0.0003 ~ 0.01% (m / m) range, no hydrogen sulfide jet fuel, gasoline, kerosene and light diesel mercaptan sulfur. Features 1, the liquid crystal display, english operation interface, can display information about the test parameters and measurement results 2, with pre-titration, preset endpoint titration, blank titration or manual titration functions, and can generate special titration mode according to user habits 3, the choice of different electrodes can be: acid-base titration, redox titration, precipitation titration, complexometric titration, and other non-aqueous titration and ph measurement 4, stirring system uses pwm modulation technology, software speed, low noise 5, perchloric acid titration system using anti-corrosive materials, can be a variety titration Technical parameters The instrument level: 0.05 1, measuring range: Ph: (0.00 ~ 14.00) ph Mv: (- 1800 ~ 1800.0) mv Temperature: (- 5.0 ~ 105.0) ° c 2, resolution: Ph: 0.01ph Mv: 0.1mv Temperature: 0.1 ° c 3, the basic error: Ph: ± 0.01ph ± 1 word Mv: ± 0.03% fs Temperature: ± 0.3 ° c ± 1 word 4, burette capacity tolerance: 10ml burette: ± 0.025ml 20ml burette: ± 0.035ml 5, burette resolution: 10ml burette: 1/10000 20ml burette: 2/10000 6, burette infusion or infusion rate: (50 ± 10) s (buret full degrees) 7, titration analysis repeatability: 0.2% Titration control sensitivity: ± 2 mv 8, stability: (± 0.3mv ± 1 word) / 3h 9, power source: ac (220 ± 22) v, (50 ± 1) hz 10 dimensions (mm): 340 × 400 × 400 11, instrument weight: 10 kg
Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. 6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem. 7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature. 8, using air instead of water cooling, saving water resources. 9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Metal tin is mainly used in the manufacture of alloys. Tin and sulfur compounds - tin sulfide, which is similar in color to gold, is commonly used as a gold pigment. Tin's modern application is as a solder for the electronics industry. Used in various purities and alloys (often with lead or indium), tin solders have a low melting point, which makes them suitable for bonding materials. Standard ASTM B29-03, BS EN 12659:1999, GB/T 469 -2005 , Content Pb â?¥ 99.99 % Density 11.34 g / cm 2 Color Bluish Weight 35 kgs / lump, 55 kgs / lump Dimension 21" x 4" x 2.5" Package Standard Sea-worthy package, fixed by belt per ton Shape Rectangular Lump Application lead-acid storage batteries Ammunition, cable sheathing, and building construction materials counterweights, battery clamps cast products such as: bearings, ballast, gaskets, type metal, terne plate, and foil Container Size 20Gp - 2.352(width) *2.385 ( Height ) * 5.90 ( Inside length ) Meter 40Gp - 2.352(width) *2.385 ( Height ) * 11.8 ( Inside length ) Meter 40HQ - 2.352(width) *2.69 ( Width ) * 5.90 ( Inside length ) Meter
Scope Standard: astm d1744, gb/t 11133 Automatic trace moisture analyzer is karl fischer coulomb titration method, determination of liquids, gases, solids trace moisture latest equipment. The instrument used in petroleum, chemical processes and products - determination of moisture; oil-filled electrical equipment measurement of moisture in insulating oil; determination of pharmaceuticals, pesticides, mineral raw materials and other substances in the water. It is the ideal instrument for trace moisture analyzer replacement. Features 1, the automatic trace moisture analyzer using digital display system, the result can be read directly 2, automatic trace moisture analyzer using electromagnetic stirring system, stirring speed can be adjusted 3, automatic trace moisture analyzer real-time display of electrolysis current size, with the end of prompts Technical parameters 1, the display system: four decimal number 2, the display unit: microgram of water. 3, electrolytic current output: 0 ~ 300ma automatic control 4, measurement range: 10µg ~ 50 mg. 5, sensitivity: 1µg h2o 6. Accuracy: 10µg ~ 1mg ± 5µg, for more than 1mg converted to 0.5 percent error-free injection) 7, power supply: ac 220v ± 10%, 50hz
Description N-NONANE (cas 111-84-2) Quick Details Chemical Name: N-NONANE CAS No.: 111-84-2 Molecular Fomula: C9H20 Molecular weight:128.26 Chemical Structure: Appearance: colorless liquid Assay: 99% Item Specification Color saybolt +28 Initial boiling point C 143 Dry point C 153 Specific gravity 20Ckg/m3 700-728 N-onane content % 99 Total sulfur ppm 1 Water content ppm 50
Appearance: brown viscous liquid. Characteristics: 1. LABSA 96% for detergent. 2. The product has the action of detergency, moistening, foaming, emulsion, dispersion and brown viscous fluid in appearance with acidity. 3. It is non-flammable, quickly dissolved in water, not dissolved in normal organic solvent. 4. The product has strong absorbency. 5. It would be unclear viscous liquid after absorbed water. Main indexes: Index Standard Appearance Brown viscous liquid Active content by wt % 96 min Free oil by wt % 1.5 max Sulfuric acid by wt % 1.5 max Color (Klett) Hazen (50g/L water sol.) 35 max Main Application 1. Hair shampoo, bath shampoo, dish detergents and complex soap, laundry powder, dishware cleaner in daily chemical industrial. 2. Wetting and clearer , dyeing assistant in textile industry. 3. Degrease agent in electroplate and leather manufacture. 4. De-inking agent in paper making.
others nameï¼?Nitrocotton; Cotton body collodion; Low nitrogen nitrocellulose 1.Nitrocellulose, also known as nitrocellulose, cotton body collodion, etc., is a nitrate ester, white or slightly yellow cotton wool, soluble in acetone. It is the product of esterification of cellulose and nitric acid. Cellulose nitrate is produced by esterifying refined cotton with concentrated nitric acid and concentrated sulfuric acid. 2.Casï¼?9004-70-0 3. Appearance: White or yellowish cotton wool 4.useï¼?Nitrocellulose has two main applications, military and civilian. The military part mainly focuses on the production of weapons, explosives and explosives, and implements the management of military products. The civil part is used in paint, celluloid, artificial fiber, film ink, cosmetics and other fields. Cellulose nitrate is a white fibrous polymer that is resistant to water, dilute acids, weak alkalis and various oils. Insoluble in water, soluble in acetone, ethyl ether ethanol mixture. Easy to change color under the sun, extremely flammable, smoke-free, instant release of a lot of gas. Different degrees of polymerization, its strength is also different, but are thermoplastic materials. It changes color easily in sunlight and burns easily. In the production and processing, packaging, storage and transportation, sales, use should pay attention to safety. Main use (1) High nitrogen content commonly known as fire cotton, used to make smokeless gunpowder; Low nitrogen content commonly known as collodion, used to manufacture spray paint, artificial leather, film, plastic and so on. (2) Used for making cultural and educational supplies, daily necessities, instrument signs, etc (3) Used in ink, leather, various nitrocellurocelluloses, rubber caps, typing wax paper, etc (4) For the production of cultural and educational supplies, daily necessities, instrument signs, etc., for ink, leather, various nitro paints, etc., for the pharmaceutical industry, photographic negatives, photographic negatives and leather manufacturing (5) celluloid, announced by the European Union on October 26, 2006, banned for the manufacture of toys.
Product Introduction SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Technical Parameters Measuring range Dew point value 80 20 Moisture content 0 19999uLL Accuracy of measurement 0.5 60 20 1.0 80 60 The resolution of the Dew point value 0.1 Moisture content 1uLL Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20 63 needs 10s 90 needs 240s 20 60 Sampling flow 0.6L min 20 Pressure range 01.0Mpa The use of temperature 20 60 Environmental humidity 0 100 RH Storage temperature 20 80 Charging time 4 hours The whole machine size 250 150 300mm3 The weight of The machine 3.5kg