Tonometer
We are authorised importer for eye tonometer reiester brand
Supplier: Keratometer, tonometer, oct, opthalmic equipments, optical coherence tomography, ultrasound, patternless edger
Nidek ark 1s is a multimodality device that includes autorefraction/keratometry/glare testing mixtures. This automatic tool measures goal accuracy and features accommodation testing and retro-illumination. The lodging can help to detect early presbyopia, latent hyperopia, and children with reading difficulty. The retro-illumination advantages patients in viewing and understanding their cataracts. Super Luminescent Diode (SLD) makes it feasible to accurately quantify patients with cataracts, corneal opacities, IOLs, and article LASIK procedures. The Nidek ark 1s offer visual acuity (VA) measurement. A glare source is illuminated together with the chart and the warmth VA can be quantified. Nidek ark 1s Autorefractor Keratometer helps you quickly assess and document vision loss in your patients. Itâ??s one of the initial autorefractor/keratometers that has glare testing accessible. The ARK 1s were used only after for research. Itâ??s essentially brand new and still under warranty. Itâ??ll be shipped in the original packing box and comes with the manual, testing eye, power cable, and computer cable (an extra thing). The Nidek ark 1s is a multimodality device that includes autorefraction/keratometry/glare testing mixtures. This automated instrument measures with goal accuracy and characteristics accommodation testing and retro-illumination. The accommodation helps to detect early presbyopia, latent hyperopia, and children with reading difficulty. The retro-illumination advantages patients in understanding and viewing their cataracts.
Carl Zeiss Cirrus HD-OCT 5000 provides highest resolution visualization capabilities and tracks retinal pigment epithelial integrity using Advanced RPE Analysis and assess glaucomatous loss with Ganglion Cell Analysis Advancing Smart OCT for Anterior Segment, Glaucoma, and Retina Anterior Segment Premier Module PanoMap Wide-Field Display Smart HD Scans En face report Carl Zeiss Cirrus HD-OCT 5000 comes with features an active eye-tracking mechanism that is able to trace and compensate eye motion in real-time and FastTrac retinal tracking to reduce eye motion artifacts without sacrificing patient
The Canon RK-F2 Fully Automatic Refractor-Keratometer helps hasten the exam process by automatically aligning and acquiring a reading for a single eye and continuing to the opposite eye to execute the same function all with one touch of a button. The Canon RK-F2 Full Ref-Keratometer is the companyâ??s latest eyecare merchandise. It simplifies the autorefraction and keratometry measurement process which weighs 11 pounds less than its predecessor and comes with a streamlined design. A healthcare professional concentrates, can mechanically align and acquire a reading for one eye and continue to the eye to perform the identical function when set to auto mode. The RK-F2, which comprises a motorized chin rest, has a minimum pupil size of 2.0 mm, an improvement over the predecessor productâ??s 2.5-millimeter minimum. Together, these features contribute to a comfortable, more efficient screening process, helping to assist the healthcare professional every time a patientâ??s student is challenging to dilate. The contemporary, streamlined, RK-F2 features innovative 3-D measurement and orientation for fast and accurate results Canon RK-F2, Together With the newest RK-F2 Full Auto Ref-Keratometer, Canon continues its heritage in providing fast and accurate measurements.
With CE and ISO13485 marks Features: This system was made up by the S350 DC and the MediView software which is developed by MediWorks. Besides the digital camera functions of the S350 DC, the MediView software can transfer the images to the computer, and then do the image capture, classification, analysis, archive and generate diagnosis report. MediView has the advantages of clear interface and easy operation, which is convenient to establish the case archives. The system can store all the case description thus the case report output is easy to operate. Real time preview, single picture capture and image lead-in are supported. Specifications: Microscope Type: Galilean optic system Configuration: Haag-streit type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 5 steps by revolving drum Total magnification and field of view (mm):6X (34.7), 10X (22), 16X (13.5), 25X (8.5), 40X (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: Continuous from 14mm to 0mm (at 14mm, slit becomes a circle) Slit length: Continuous from 14mm to 1mm (at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm Filter: Thermal safety, UV, Cobalt Blue, Red-Free Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree Lamp: German imported 6v, 20w halogen lamp (OSRAM) or LED lamp. Accessories: Applanation Tonometer Adaptor, Beam Splitter, DC Adaptor, DC, BacLite Background Illumination Model, MediView Image Capture System software etc... Yellow Filter, Amber Filter and Measuring Eyepiece are available Triple wall corrugated fibreboard boxes Gross Weight: 26KGS Net Weight: 25KGS Dimensions: 740mm X 450mm X 500mm
Slit Lamp Image Capture System (Video) With CE and ISO13485 marks Features: This PRI system was upgraded by the S350 Slit Lamps with the CCD Adaptor, Beam Splitter and CCD with high speed and resolution. Besides the functions of the S350 Slit Lamps it also has the following functions: 1) 5.0 mega high-definition static image capture. 2) Easy operated patients' information management, diagnosis report can be edited. Microscope Type: Galilean optic system Configuration: Haag-streit type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 5 steps by revolving drum Total magnification and field of view (mm):6X (34.7), 10X (22), 16X (13.5), 25X (8.5), 40 X (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: Continuous from 14mm to 0mm (at 14mm, slit becomes a circle) Slit length: Continuous from 14mm to 1mm (at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm Filter: Thermal safety, UV, Cobalt Blue, Red-Free Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree Lamp: German imported 6v, 20w halogen lamp (OSRAM) or LED lamp. Accessories: Applanation Tonometer Adaptor, Beam Splitter, Video Adaptor, Video, BacLite Background Illumination Model, MediView Image Capture System software etcí¡ Yellow Filter, Amber Filter and Measuring Eyepiece are available Triple wall corrugated fibreboard boxes Gross Weight: 26KGS Net Weight: 25KGS Dimensions: 740mm X 450mm X 500mm