Well Testing ESD Control SystemWell Surface Testing Emergency Shutdown System Overview of the ESD Control System The Emergency Shutdown System-ESD control system is the long-range capital equipment, the ESDsystem controls the surface safety valve / SSV. The ESD Control console is composed of the control cabinet, manage ducts, etc. The surface safety valve(SSV), for often closing type. When use, The ESD control system urges the surface safety valve / SSV to be opened through the pressure medium. If keepdriving the pressure, the surface safety valve/SSV will be in the state of opening all the time. Features of the ESD Control System * Carry out remote control of the surface safety valve* Easy to operate and maintenance Emergency Shutdown(ESD) system SpecificationPneumatic Source Pressure0.1~1.0MpaNon-Continuous Max. Pressure 46MpaContinuous Max. Pressure35MpaFlow rate1.36 l/minPressure ratio1:46SSV Drive pressure21MpaESD Max. Working pressure35Mpa JC Petroleum Equipment Facotry manufactures and supplier the various wellhead manifold andrelated parts to meet different requirement in oulfield service operation. The wellhead manfioldsare conformed with API 6A and API16C specification, and applied for high pressure and high temperature working condition. The wellhead manifold include choke and kill manifold, fracturing manifold, testing manifold, drilling floor manifold. etc And we can design the wellheadmanfiold as per the customers' requirementsWell Testing ESD Control SystemWell Surface Testing Emergency Shutdown System
Supplier: Industrial safety (ppe), height safety, fire detection & protection system, gas detection system and building management system (bms) product.
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
Supplier: Security Entrance Control Systems, Testing Instruments, Measuring Instruments
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.! Features & Benefits: 1. Designed for sprinkler standards NFPA 13, 15 and 16. 2. Dual hazard operation. 3. Cross-zone (double-interlock) capability. 4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). 5. Optional Digital Alarm Communicators
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. Features & Benefits: Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation Meets International Building Code (IBC) seismic requirements
1. The ESDMAN 001-6809 ESD Access Control System is designed for fast, frequent, and accurate testing of ESD personnel grounding items. Its unique design embeds an ESD tester, computer clock, touch screen display, IC / ID card reader or barcode scanner, Ethernet module etc. in a compact stainless steel enclosure. 2. This system can be worked with tripod turnstile, swing gate, flap gate, electronic lock & air shower room. In addition, it could provide basic ESD testing management, stop operators entering EPA without ESD testing. 3. Whatâ??s more, test results are electronically stored in the system and easily downloaded as attendance management, which has the function of distinguishing and setting up different attendance statement. It will automatically store 500,000 testing results while software is closed and PC is off-line. 4. It meets the requirements of the ANSI/ESD S20.20 & IEC 61340 in the USA and Europe.
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
QN-RD173T/X Adjustable/fixed Frequency Remote Control Duplicator for Automatic Gate Garage Door Feature Functions and Features 1. face to face remote control duplicator 2. customized frequency for remote control duplicator such as 315Mhz, 433Mhz 3. remote control duplicator can copy most fixed code remote control 4 . Accept OEM and ODM service. Model No.:QN-RD173T/X Frequency:Fixed Code Modulation:FSK Operatiing Range:50-80M Button Durability:100 000 times Battery: 27A Gurantee:2 years OEM and ODM Services:Yes Application:Garage Door HS Code:85269200 Others:Battery and keychain included;
QN-RD069T Adjustable Frequency 2 Buttons Universal Garage Door Remote Control Feature Functions and Features 1. lonf range wireless remote for garage door 2. compatible with all fixed code remote with 315 and 433,92 Mhz 3. transmits in 433.92 Mhz 4. accept OEM, ODM service Model No.:QN-RD069T Frequency:Fixed Code Modulation: FSK Battery: 27A Operatiing Range:50-80M Button Durability:100 000 times Gurantee:2 years OEM and ODM Services:Yes Application:Garage Door HS Code:85269200 Others:Battery and keychain included;