Especially developed for indication and
supervision of the single-phase circuit,
replaces an analogical voltmeter, reducing
installation manpower and optimizing the
used one of spaces in the panel.
Ideal for protection of single-phase networks
is monitored and generally to own alarm
superior and inferior. Protection of the
parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
single phase AC voltage panel meter voltmeter type : NP-60 mounting diameter : 22mm color : red lamp voltage : AC 20-500V
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Specifications Current inputs (TRMS) Communication (Option) CT primary 10 000 A Link RS485 CT secondary 1 and 5 A Type 2 ... 3 wires half duplex Sampling Rate 2 per sec Protocol Modbus RTU mode Resolution 0.001 to 1, depending on the range MODBUS speed 4800/9600bauds Burden < 0.5VA, < 0.2VA in 20A Analog Outputs (Option) Auxiliary power supply Number of outputs 1 channel AC voltage DC/AC 85~265 ± 30 % Type Isolated Frequency 50 / 60 Hz Range 0 / 4 ... 20 mA or 0-5V Consumption < 10 VA Maximum current 30 mA Front panel Alarm Outputs (Option) Display Type Red LED Super Bright Display Number of relays 1 channel Maximum Display 9999 Counts Type Passive nodes Polarity Indication "-" is indicated for negative input(option) Weight Case / Housing Material Approximate 250~400g Installation Panel mounting Environment Terminal Block Thermoplastic with Tin Plated Brass Terminal Calibration 27°C ± 5°C Dielectric Strength Operation 0 to 50°C, RH < 70% 2.5 kV at 50Hz for 1 min Storage -10 to 60°C, RH < 70%
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Title goes here. ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RJ45 Ethernet MODBUS-TCP Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes