Main Features: 1. Measuring scope:AC 0.00A-6000A(50/60Hz)
2.Accuracy:AC 0.01A
3. Clamp mouth: 200mm
4. LCD display:44mm*27mm, Data Storage:4200sets
5.Data upload: RS232 interface6.Working Time:100hours
Model No.:MEWOI9000GB
Name: MEWOI9000GB Flexible Coil Leakage Current Monitoring Recorder/Logger
Host Dimension :W*L*H75mm*170mm*30mm
Time Setting: Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-
store function is turned off
Recording Time: Continuously operate for about 100hours at the power-saving mode Line Voltage: Line with a voltage up to AC600V
MEWOI9000GB flexible high current clamp / logger is specially designed for field-line testing, monitoring, recording AC leakage current and Large current, It consists of host, flexible current clamps, monitoring software, communication lines and other components. Widely used in electric power, telecommunications, meteorology, railroad, oilfield, construction, measurement, research and teaching departments, industrial and mining enterprises and other fields. Particularly suitable for cable-intensive places, the wall transformer core grounding current test, thick wire cable test, relay protection , frequency conversion, semiconductor switches, electronic power conversion equipment, arc welding and other serious signal distortion current testing industrial environments.
Flat Cable M&P is able to support a full line of flat cable and flat ribbon cable for electronic applications. Providing both power and data transmissions, flat cables are mainly used for internal connections within the equipment. They are available in a wide range of configurations to accommodate different connection and data transmission requirements and the range of sizes of the equipment using the cables. Flat cables provide consistent performance due to their layout and the spacing between the cables and are lighter, thinner and more flexible than other cables. Features of Our Flat Cables & Wire * Flat, ribbon and twisted configurations, with different levels of flexibility. * Shielded or jacketed cable to reduce signal interference. * Range of pitches and pin configurations to accommodate the application requirements. * Easy to fasten with clamps, adhesive, and tape. We provide custom services, including marking, kitting and custom cable design to provide you with a custom solution for your cabling application. Contact us to find out more about Flat Cables and Wires.
Paraflex UNI-R Multistrand FR PVC Insulated Cu. Paraflex Multistrand FR/FRLS PVC insulated Cu. Paraflex round multicore Flexible PVC insulated Cu. Paraflex submersible (3-coreflat) and UNI-R Submersible PVC Insulated Cu. Paraflex Aluminum Unarmored, Single Core twin flat 3 core and 4 core round solid and XLPE Aluminum Twin flat (Heavy Duty) Paraflex PVX VIR Copper Cabales. Paraflex Co-Axial wires. Paraflex Oxygen Free speaker and camera wire. Paraflex twin flat and copper flexible cables. Paraflex PVC FR tape. to 630 sq.mm core, 2 core, 3 core, 3.5 core and 4 core both in Al & Cu. Under IS: 7098 (Part 1), IS: 1554 (Part 1). Aerial Bunch cable IS: 14255 range 16 sq.mm to 95 sq.mm. PVC Rigid Conduits IS 9537 Part-3, 2003
Main Features: 1. Measuring scope:AC 0.00A�20KA(50/60Hz) 2. Accuracy:AC 0.01A 3.Clamp mouth: Φ300mm4. LCD display, Data Storage 4.200sets 5.Data upload: RS232 interface 6.Working Time:100hours Model No.: MEWOI9000G Name: MEWOI9000G Flexible Coil Leakage Current Monitoring Recorder/Logger Rated Power: about 5mA at the power-saving mode, maximum current consumption: 20mA Functions: Field-line testing, monitoring, recording AC leakage current and Large current Lead Length:2m
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.