Name: CANopen RTD Remote IO Module (8RTD)
Model No.: M340c
The M340c CANopen RTD Remote I/O Module is an industrial class, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, provides a CANBus interface. It provides multi I/O, supports standard CANopen Protocol, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
The M340c CANopenRTD Remote I/O module provides 8 RTD inputs, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, the resolution is 0.1°C, measure range -120°C ~420°C. All of the I/O with high sampling frequency and special filtering strategy to ensure its reliable.
The M340c CANopenRTD Remote I/O module can work at 12~36VDC with anti-reverse protection design.
Main Feature:
1) Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2) Power supply 12~36VDC with over voltage and phase-reversal protection;
3) 1 CANBUS Interface, comply with CANopen specification CiA301,CiA401;
4) Group 2 Only Server (non UCMM-capable) ;
5) Support Predefined Master/Slave Connection Set;
6) Support CANopen heartbeat and shutdown messages;
7) Provide EDS file for standard CANopen master interface;
8) 8 RTD input support PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, measure range -120°C ~420°C;
9) High sampling frequency and special filtering strategy to ensure reliability;
10) LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
11) Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
12) Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Floating cable which can be applied to underwater robot equipment, either in fresh water environment or in seawater environment. It is widely used in marine exploration robot, underwater ROV UAV remote control submersible, underwater camera, underwater construction, underwater search and rescue robot, pipeline detection robot, submersible pump and the link between various underwater electrical equipment and shore based equipment; Link of signal transmission, power supply and equipment control system from underwater to water.
OPC UA I/O Controller BL200UA is a new type of I/O system that special designed for Industrial 4.0, it supports OPC UA Protocol, built-in programmable logic control, edge computing. it suitable for IIoT Application and Industrial Automation. The EdgeIO I/O Controller BL200 includes lots of advantages to ensure its suitable for Industrial Automation and IIOT Applications. EdgeIO BL200 supports Scalable Networking, can connect one by one to save wiring costs. The EdgeIO BL200 suitable for IIOT Applications, built-in Cloud Drivers, the users can click then connect to cloud platforms. The EdgeIO BL200 supports Cyber Security and Data Security, provides VPN, SNMP, TLS, SSL, etc. The EdgeIO BL200 can be used as a simply PLC, connect IT and OT directly, easy to create the IIOT Solutions. Saving wires and wiring cost, make it more easier and cost-effective to you industrial applications.
The M120 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1-2 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system. The M120T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements. The M120T Ethernet Remote I/O module provides 4 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300KHz high speed pulse output or relay outputs, 2 channel 12bits analog outputs, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it reliable.
Control Cable are PVC insulation, XLPE insulation, fluoroplastic Insulation materials, different materials such as silicone rubber insulation performance cable products for In power stations, substations, factories, petrochemical, and other companies controlled remotely controlled loop, as the connection between the lines of various types of electrical instrumentation and automation devices, from the role of the various power or signal transmission, so that the entire electrical system safe, Reliable operation. Control cable is suitable for power station, substation, factory and petrochemical industry.
Power Modules are Point of Load (POL) DC-DC converters integrating controller chips, chokes and I/O capacitors into a single power management package for step-down(buck) applications. The low profile and compact size enables significant saving of board space, high efficiency enhances application performance, and design structure allows automated assembly by standard surface mount equipment
BRAND: WEST PID TEMPERATURE CONTROLLER WEST Controller: Model: WEST-6100+,P6100 Model: WEST-4100+,P4100 Model: WEST-8100+,P8100 Features and Benefits: Dual setpoints & optional remote selection Plug-in output modules allow installing just the functions needed in Expanded user-selectable operator modes in User-selectable plug-and-play output cards in Process and loop alarms in Adjustable hysteresis in Optional 10V SSR driver in Improved Windows PC configuration software Improved easy-to-use HMI Jumperless input configuration Auto-hardware recognition Faster communication speeds More security options Backward compatible panel cutout, housing and terminal wiring capability P6100/P6170/P8100/P4100
MITSUBISHI PLC , ALL MODEL ARE AVAILABLE. Mitsubishi PLC Module FX5-4AD-ADP Mitsubishi PLC Module FX2N-2DA Mitsubishi PLC Module FX3U-CNV-BD Mitsubishi PLC Module FX2N-8DA Mitsubishi PLC Module FX3U-485ADP-MB Mitsubishi PLC Module FX3U-232ADP-MB Mitsubishi PLC Module FX3U-ENET-ADP Mitsubishi PLC Module FX3U-4AD-TC-ADP Mitsubishi PLC Module FX2N-4DA
Supplier: Relay interfacing modules, field interfacing modules, diode modules, cable assemblies, wiring harnesses / wire harness, power distribution boards ( pdb ) / switched mode power supplies ( smps ), plc training kits, plc control panels / drive panels, automation panels, control panels, control panel enclosures, stainless steel enclosures, purging panels, frp purging panels, junction boxes, ss junction boxes, control desks, kiosks
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".