solvent free flooring epoxy system two components used for producing high quality epoxy smooth flooring with high glossy surface. Where it based on epoxy resin and agents which are specially selected for their ability to withstand chemical attack
Properties @ 25 c
Color: White , grey , all required colors
Gloss: Glossy
Solid content by (WT): 100 %
Mixing Ratio: 4 A : 1 B
Specific gravity (mix ): 1. 60 0.03 g/cm3
Pot life: 35 min.
Temp. of Application: ( 15 35 ) C
Full curing time: 7 days
Rate of use: 3 -5 m2/ kg ( depending on surface conditions )
DATA SHEET FOR EPOXY EPOXY COATING :- INTRODUCTION - EPOXY COATING (HYB) is a two part high solids solvent free epoxy phenolic resin based coating system designed for hard wearing, smooth surface finish for floors, walls and on steel structures. Nonskid surface finish can be achieved on floor, if required. FEATURES: 1) Hard Wearing 2) Non Dusting 3) Excellent Surface Finish 4) Non Smelling 5) Good Aesthetics 6) Highly Chemical Resistant APPLICATION: 1.Stir well before mixing Part A and Part B and mix in the prescribed ratio. 2.Apply one coat of EPOXY primer on the clean and dry surface. 3.EPOXY COATING (HYB) should be applied on the surface by brush or roller within 24 hrs. After application of primer coat it should be allowed to air dry for min. 4 hrs. Preferable in a dust free atmosphere. 4.Apply min. 2 coats with the intercoat interval of 6-8 hrs. PRODUCT SPECIFICATIONS: Application - Brush, Roller Mixing Ratio - As Directed on Packing Port Life - 30 Mins. Drying Time - Touch Dry- 30 Min, Hard Dry 6 Hrs. - Intercoat Interval 6-8 Hrs. Min. - Dry Film Thickness 125-150 Microns/per coat - depending on porosity Covering Capacity - 6-8 sq.met/kg per coat depending on porosity, roughness & method of application. Color Shades - All Standard Shades RECOMMENDED USES: 1) Food & Pharmaceutical 2) Work Shop 3) Clean Room Application 4) Chemical Resistant Coating for Concrete& Steel 5) Petrochemical, Fertilizer plants METHOD OF APPLICATION: SURFACE PREPARATION The long-term durability of the applied Epoxy coating (HYB) epoxy coating is dependent on the adhesion between sub-base and coating material. It is most important therefore, that the substrate surfaces are correctly prepared prior to application. 1.Before application of the Epoxy coating (HYB) surface should be free from loose partials, rust, oils, grease or earlier coatings and should be totally dry. 2.New concrete or cementations surface should be placed at least 28 days and have a moisture content of less than 5% before application of Epoxy coating (HYB) 3.After surface is dry, all repair work like sealing of joints, cracks filling of cavities and crevices should be carried out. HEALTH & SAFETY - Keep the containers tightly closed when not in use. Avoid contact with skin & eyes. It comes in contact with the body, wash affected parts with plenty of water and contact a doctor. Other known sector for Epoxy floor lining, Epoxy garage floor lining, Concrete epoxy lining, Concrete floor epoxy lining, Epoxy pipe lining, Marine epoxy lining, Sub marine epoxy lining, Basement lining epoxy floor shield, Louisiana, Oregon, Chip lining color epoxy floor, Aviation lining epoxy interior.
Epoxy Solvent Free Primer
Epoxy Primer Solvent Base
Epoxy Putty Solvent Base
Epoxy Topcoat Solvent Base
>=100 Liters US$ 5.00 Payments:This supplier also supports L/C,T/T,Western Union payments.
Epoxy Floor Coating (interior Floor Coat) Covered/underground Car Park/garage Warehouse Coatings Factory/food Plant Coating Industrial Floor Coating Self Levelling Floor Coat Hygienic Coating (anti-bacterial)
Polyethylene(PVC) geomembrane, as a high-performance waterproof and impermeable material, has many remarkable advantages. Thickness: 0.1mm-3mm Width: 2m-6m Color: Black/White/Other colors Following is our PVC geomembrane Thickness 1.6mm specifications: Tensile Strength (vertical and horizontal): 20MPa/mm Elongation at Break (vertical and horizontal): 580% Right-angle tearing strength (vertical and horizontal): 180N/mm Water vapor permeability coefficient: Using temperature range: +70~ -70 Puncture strength 360N Water impervious: 100% Root resistance: 100% Difference Between PVC Geomembrane and HDPE Geomembrane PVC geomembrane and HDPE geomembrane have significant differences in physical properties, treatment difficulty, joint treatment, puncture resistance, and resilience to deformation. Physical Properties and Suitable Environment: PVC membrane: relatively soft and easy to bend, suitable for general waterproofing projects, swimming pools, and wastewater treatment, etc. HDPE membrane: has higher strength and wear resistance, suitable for engineering projects with higher strength and durability requirements, such as water conservancy projects and landfills. Handling Difficulty: PVC membrane: Due to its flexibility, we can make seams in controlled factory conditions, typically requiring fewer on-site seams than HDPE geomembrane. HDPE membrane: Handling in cold weather conditions can be challenging and requires sewing outdoors. Puncture Resistance: PVC membrane: It is harder to penetrate than HDPE and has high elongation characteristics, allowing it to adapt to site changes without reinforcement. HDPE membrane: While it has elasticity, it becomes plastic after exceeding its yield point and no longer has elasticity. Deformation Recovery: PVC membrane: Most of the deformation can be recovered, with a high tensile elongation, suitable for engineering projects with larger design strain limits. HDPE membrane: Deformation after exceeding the yield point cannot be recovered, and the material properties will change. We should select the appropriate geomembrane according to the specific project requirements and the use environment. HDPE geomembrane is suitable for projects that require high strength and durability, while PVC geomembrane is suitable for general waterproofing projects and water treatment.