PCT200i is specially designed for current transformer characteristic test. PCT200i owns more test items and higher technical parameters.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
Features
Test CT according to IEC60044-1/6, IEC61869-2, C57.13
Can test all types of CT, including bushing and GIS type CT
One test can get all CT parameters
Fast test time for excitation test
10kV knee point test: 50s
1kV knee point test: 15s
Ratio check up to 30,000:1
Knee point check up to 30,000V
PT test functions are also in-built
Test results can be saved to flash disk
Optional Excel format report generation
Large color LCD display
Weight : 10kg
PCT200Ai is the current transformer test set can finish various tests of different transformers. Compared with PCT200i,its accuracy is higher.This CT analyzer can test the 0.2s class CT.Only this CT analyzer - the high-accuracy current transformer test set has passed the tests held by Wuhan High Voltage Research Institute.The max permissible error of ratio measurement is �0.05% and max phase measurement is �2min. Features Can test M/P/TP type CTand PT Ratio check up to 35000:1 and 45000:5 Knee point check up to 45000 V Standards: IEC 60044-1, IEC 60044-6, IEC 61869-2, ANSI/IEEE C 57.13 Result saved directly in Excel format Report can be transferred to flash disk via USB port. Weight : 14kg
CT PT load box Please use an appropriate power cord for this product. Only the power cord dedicated to the machine or a suitable gauge can be used. Connect and disconnect properly. Please do not connect or disconnect the test lead if it is connected to the charging terminal. Ground the machine. The grounding pole of the machine enclosure must be grounded, unless the product is grounded through the power ground wire. To avoid electric shock, the grounding conductor must be connected to the ground. Before connecting the input or output terminals, make sure that the machine is properly grounded.
Supplier: Our high voltage testers cover full range: high voltage hipot tester, circuit breaker switchgear tester, transformer tester, relay protection tester, ct/pt tester, moa/insulator tester, sf6/insulation oil test equipment, resistance tester, etc.
Supplier: Electrical panels, transducers, meters, mcbs, mccbs, breakers, ct and pts, transformers, synchronizers, surge arrestors
GBCCUM21PF231A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF231A CCUM21 Case Size - 1-1/2D VERT. 10T Current Rating Cup unit - 5 Amp CT V.T Secondary Volts - 110 V ac Torque Angle (MTA)I Lead V- 30 Degree Frequency - 60 Hz Aux. Voltage - 30 V dc Contacts - 2 N/O S/R Flag - Yes Mounting - Flush Timing Range - 0.5 - 5 Secs Note:- This relay to be tested for 60 Hz only. Name Plate VTT RZF9151-601 Name Plate RFH9072-604 Outline Diagram MFJ 013 Wiring Diagram MPDZ609-01-1
GBCCUM21PF232A DEFINITE TIME REVERSE POWER RELAY 60 HZ Technical Specifications CCUM21 Model No : CCUM21PF232A Case Size - 1-1/2D VERT. 10T Current Rating Cup unit - 1 Amp CT V.T Secondary Volts - 110 V ac Torque Angle (MTA)I Lead V- 30 Degree Frequency - 60 Hz Aux. Voltage - 110 / 125 V dc Contacts - 2 N/O S/R Flag - Yes Mounting - Flush Timing Range - 1 - 10 Secs Note:- This relay to be tested for 60 Hz only. Name Plate VTT RZF9151-601 Name Plate RFH9072-604 Outline Diagram MFJ 013 Wiring Diagram MPDZ609-01-1
GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
Supplier: Rockwell, brinell, vickers hardness testers, universal testing machines, impact testing machines, fatigue testing machine, compression testing machine
Buyer: Bajaj, bharat forge, tata steel, venus wires, ador welding, l&t, godrej & boyce, kirloskar, pwd department, saroj, mayura steels
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.