We use construction technologies australia for our glues, adhesives, grouts and waterproofing. Each project requires specific products to ensure a lasting finish. If you are tiling over tiles or tiling on new substrates it is super important to use the right products in the right order.
Your grout selection can make or break a job so again its best to pop in, see the colour selection and discuss with our team which is best for your tiles
Specifications 1.odorless 2.low VOC 3.antimicrobial 4. mildew resistant 5.environmentally friendly 6.waterproof 7.Scrub resistance Description It is an enhanced mildew proof product adopting nano-scale Ag+ antimicrobial and mildew proof technology, integrating odorless formula, with fresh product smell, smooth paint film, durable and beautiful paint.As an affordable and environmentally friendly product with excellent decorative performance, it is characterized by fresh smell, environmental health, strong covering power, large painting area, convenient constructionapplication, short constructionapplication period, etc. Specification Data Solvent: Water Pigment: Non-lead pigment Theoretical Solids By Volume: more than 50% Theoretical Coverage: Theoretically 1 litre of this product covers 12 sqm in 1 coat Coverage varies considerably depending on application methods and surface roughness and porosity. Shelf Life: Minimum 12 months at 77F(25C) unopened and store in cool and dry places. Recommended Film Thickness: Wet: 80 micron Dry: 30 micron Dry Time: At 77F (25C) and 50% R.H. to recoat Touch Dry: 1 hours Recoat : 2-3 hours Application: Brush, Roll, conventional spray or Airless Spray. Thinner: Thin up 15% depend on different application methods & temperature. Do not over thin by adding more than 30% water. Brush or Roller: For sealing new or bare surfaces thin with up to 1 part of clean water to 5-10 parts of paint(10%-20%) Conventional Spray: Add up to 1 part clean water to 5 parts paint(20%) Airless spray: do not thin Clean-up: Clean up equipment with water Typical painting system Substrate System All kinds of Wall surfaces 1.Alkali Resistance Primer (1 coat) 2.Emulsion Wall Paint (2 coats)
Supplier: Refractory bricks, high alumina bricks, acid proof bricks, tiles and castables, all mortars and fire clay, low cement castables, insulating castables, conventional dense refractory bricks, insulation bricks, cold face, hot face insulation bricks, hot face insulation bricks, acid resistant bricks/components, membranes, acid resistant cement, construction chemicals, class 1 ar tiles and bricks 38mm and 75mm, 4457 vitrified ar tiles with 0% water absorption, 20mm & 25m, primer, mastics, pot. silicate cement, coerce cement, furnace based cement, crushed refractory boiler bed material, acid resistant tiles, acid resistant brick fireclay type, acid resistant brick red shale type, bitumen primer, epoxy resin & hardner, furan powder and syrup solution,
* PHOSCAST Phoscast : Phosphate Bonded Castables * PURPOSE customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system. BACKGROUND * Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles. * GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates. Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion * Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected. APPLICATION Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
APPLICATION OF SK-HB K-SILICATE MORTAR : * K-SILICATE is used for jointing Acid Resisting brick in construction of vessels in suited for construction of fume chambers and stacks handling hot, dry Acid fumes and vapors. It is also used for jointing chemical resisting stoneware pipes. K-SILICATE cement is good bedding material for Acid â?? Resisting bricks and tiles. The concrete surface needed protection should be dryed, clean and rough. The bricks or tiles will be set with K-SILICATE cement over concrete surface applied with a suitable an impermeable interliner. When Bedding and Jointing Materials are the same. On the treated surface bricks or tiles are bedded to a thickness of about 6 mm and tamp gently with a wooden piece till the paste squeezes out of joints. The paste that is squeezed out of the joint should be removed by trowel with good finishing. After the mortar of the joint is dryed treat the joints with 20% Hydrochloric Acid Solution by means of brush. A.R.lining should be always in contact with Acid and not with water. Concrete subtract like Floor, Wall, tanks and similar surface should be protected with a membrane of Bitrok Mastic or compound steel tanks should be protected with rubber or PVC subjected to chemical conditions and temperature of chemical media. The Brick lining is recommended over the protective layer of Bitrok Mastic. When Bedding and Jointing Materials are Different. Spread the silicate type mortar about 6 to 8 mm thick on the back of the tile or brick. Press the tile on the bed leaving required space for joints between tiles for bricks. After the bedding mortar is set, fill Mp the joints with specified cement.PRODUCT DATA SHEET FOR SK-HB ( K-SILICATE) MORTAR A general purpose cement for acid conditions Resistant to High & medium concentrations of most of the common organic and inorganic acids except Hydroflouric acid. Recommended where the concentration of the acid is high suitable for high temperature. Unsuited to aqueous solutions, alkaline conditions. PREPARATIONS OF MORTAR : * Measure 1 part by weight of K-SILICATE solution into a suitable mixing pan. * Add slowly and gradually 3 parts by weight K-SILICATE mortar and mix thoroughly to form a smooth mortar. * In hot season very large batches of mortar will become stiff quite rapidly therefore small batches, not exceeding 4 to 8 kgs. Will be prepared. * The cement mortar will be used before it starts setting.
This is chemical setting Furan based chemical resistant mortar which is combination of Liquid and Powder, when mixed in proper proportion from workable mortar which after setting and curing give of liquid and give black highly cross linked composites. Furan When set and cured is resistant to highly corrosive acids, alkalis and to powerful organic solvents such as ketones, Aromatic and Chlorinated solvents. It has extreme resistant to Acidic & alkalis, Salts, Greases and Detergents. It resists to Organic & Inorganic acids at their boiling temperature. It is suitable against mild chlorine Gas (dry) phosphorous trichloride, pyridine at room temperature. Furan is especially useful where resistance to mixed media such as aqueous acids /alkalis and organic solvents is needed in chemical plant process and waste streams. Carbon filled Furan is used against corrosive effect of hydrofluoric acid & its salts. PREPARATION OF FURANE MORTAR : Mortar consist of Furan solution and Furan powder. The average mixing ratio necessary to obtain mortar with good working consistency is 1 part by weight Solution & 3 part by weight powder. The ratio will vary slightly depending on temperature and working conditions.Stir the liquid thoroughly before using. Place liquid in a suitable shallow mixing pan. Add powder by weight in the solution mix thoroughly and rapidly until all lumps are dispersed and the mortar is completely homogenous. Spread out the mortar in a thin layer, not more than ¾ thick, to dissipate the heat of reaction and lengthen the working life. Batch size can be varied depending upon the temperature and the speed with which the masons are working. Very large batches will become stiff quite rapidly. Make sure that all the Furan Motrar is used from the pan before another batch is mixed.When working at temperature above 40 C, very small batches not more than 2 Kgs, should be prepared. When working at temperature below 15C the liquid should be kept warm.
Acid / Alkali Resistant Tiles/Bricks * Our Acid proof tiles, Acid alkali resistant tiles, Chemical resistant tiles are fully vitrified tiles which are manufactured using special non ferrous clay, processed at extremely high temperatures this process causes the raw materials to fuse and form a compact mass with an extremely low water absorption of less than 0.5% resulting in the formation of a very strong body with a flexural strength of 38 N/mm2, solid through color fade proof with a very hard surface Mohs hardness of 7. * The acid resistant tiles come in a range of sizes and thicknesses from ranging from 8-25mm. Our acid proof tiles meet stringent specification norms of IS 4457:2007 and relevant ASTM/DIN standards which ensure excellent performance in Acid/Alkali/Chemical (expect Hydrofluoric acid and its derivatives). Corrosion Protection Applications * Factory Floors subject to corrosion from Chemicals, Acids, Oil & Solvents * Pickling tank and surrounding areas * Food & Beverage Industry flooring * Battery rooms and Control rooms * Demineralization plants * Walls of washing and Paint shop areas * Acid Resistant Tiles Manufacturers India * Our acid proof tiles provide excellent abrasion resistance, anti-skid properties for worker safety and high aesthetic appeal. We also provide specialized corner tiles for reducing chances for acid attack through construction joints. Our standard sizes are 200x100, 200x200 & 300x300 millimeters.
Pipes are essential components of any oil and gas operation. Whether transporting crude oil from the wellhead to a storage tank or transferring natural gas from a processing plant to a pipeline, pipes are used throughout the industry. Understanding their functions and benefits is key to running an efficient, cost-effective operation. please send us your inquiry to inform you the price and payment terms. AVAILABILTY: 148 PIPES LENGHT: 12 M DIAMETER: 80CM THICKNESS: 2.70 CM TOTAL WAIEGHT: 1200 METRIC TONS
Camping tent, outdoor camp gear, waterproof tents Model: E-0024 four side Double layer Size: 240*240*170cm Materials: 230T water proof PU layer cloth Bottom materials: 210D oxford PU layer cloth. Support rod: stainless spring Auto (one set) Weight: 5kg Packing size 87*30*37cm/6pc Color: Ink green, army green, sky blue Remark: If want separate use outer tent and inner tent, need extra support rod.