CE, ISO 13485 and Rohs certificates
Pneumatically driven and electrically controlled system
Built-in ventilator, LED display screen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.
2-tubes Flowmeters, O 2 & N 2 O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,MANUAL
Tidal Volume: 50~1500ml
I/E Ratio: 1:1.5 ~ 1:3.0
One vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 4~40 bpm;
Ptr: -1.0kPa ~ 1.0 kPa
CO 2 absorber capacity : 1 kg
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,
AC power malfunction,Battery low power
Features
Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Anesthesia Ventilator: Built-in ventilator, LED display screen
Standard integrated metallic modular respiratory circuit; completely solves the problem of gas sealing under high temperature disinfection, easy to clean and disinfect
Equipped with electronic pressure differential flow sensor, imported respiratory control valve
Vaporizer: Imported tank components assembled locally; Enflurane, Isoflurane and Sevoflurane (Halothane optional). Also possesses self-compensating functionality
Multi-parameter Patient Monitor: Optional
High precision four tube flowmeter, fitted with interlocking oxygen-nitrous oxide supply, guarantees oxygen output is never lower than 21%
Nonhazardous environmentally friendly frame, with automated self-checking function during startup and an automatic self-calibrating sensor
Power Failure Support Functions: Automatically converts to backup power mode during AC power outages
Alarms: Audible and/or visual alarms for tidal volume, airway pressure, asphyxia, power failure, oxygen failure and other alarms, also features a alarm query function
Equipped with advanced international rotating Na-lime tank, uses imported PPSU material and temperature resistant to 134°C
YJ-8501 Anesthesia Machine is equipped with an accurate dedicated anesthetic vaporizer and a safety device for preventing cyanosis and a necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient. Pneumatically driven and electrically controlled system Built-in ventilator, 8.4 LCD display screen Closed; Semi-Closed; Semi-Open working mode Applied for Adult and Pediatric
Technical data: Concentration range: Halothane : 0 to 5% Enflurane : 0 to 5% Isoflurane: 0 to 5% Sevoflurane: 0 to 8% Temperature range: Ambient and vapor temperature During operation 15 to 35oc During storage (empty, dry wick) -40 to 65oc Flow range 0.2 to 15l/min 0.2 to 10l/min (normal usage) for concentrations >5 vol.% Filling volume for anaesthetic agent: About 340 ml with dry wick About 300 ml with moist wick Maximum angle of tilt During transport (control dial at 0 ) any position and angle During operation straight up Warm up time: 5min Mounting type: Draeger plug in, selectatec compatible, cagemount (iso 23mm tapers), Fix mount, cagemount with interlock Filler type: Pour fil, easy-fil (isofulrane, halothane, enflurane) Pour fil, easy-fil, quik fil (sevoflurane) Standard: Ce, iso13485, iso9001, iso 8835-4, 93/42/eec mdd.
Ar-325 anesthesia machine Main body High-strength engineering plastic rack, light, Beautiful and corrosion resistant Scope of application Adult, child Gas source O2: 0.27--0.55mpa n2o: 0.27--0.55mpa Flow meter O2 : 0.1--1.0l/min 1.1--10l/min N20: 0.1--1.0l/min 1.1--10l/min Air : 0.1--10l/min O2, n2o linkage and n2o stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure
Product Description: Datex Ohmeda S/5 Aespire Clinician-inspired solutions help improve patient care Features - Enhanced monitor integration capabilities with our Datex-Ohmeda Anaesthesia Monitor and Compact Anaesthesia monitor - Lightweight and compact for easy manoeuvrability - Optional integrated auxiliary O2 flowmeter and suction control General Specifications: Dimensions - Height: 134.5 cm/52.9 in - Width: 72 cm/28.3 in - Depth: 73 cm/28.7 in - Weight: Approximately 108 kg/238 lb. Top shelf - Weight limit: 34 kg/75 lb. - Width: 66 cm/26 in - Depth: 40 cm/15.75 in Work surface - Height: 81.7 cm/32.2 in - Size: 2160 cm-2/334 in-2 DIN rail - Side of machine: 34.5 cm/13.6 in Drawers (internal dimensions) - Height: 17.5 cm/6.9 in - Width: 33 cm/13 in - Depth: 26.5 cm/10.4 in Absorber bag arm (optional) - Arm length: 30.5 cm/12 in - Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in) Casters - Diameter: 12.5 cm/5 in - Brakes: Individual locking front casters Electrical Specifications Current leakage - 100/120 V: < 300¼A - Power - Power input: 100-120 Vac, 50/60 Hz - Power cord: Length: 5 m/16.4 ft. - Rating: 15A @ 120 Vac Inlet/outlet modules (120 V) - System circuit breakers: 15A - Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer Pneumatic Specifications Auxiliary common gas outlet - Connector: ISO 22 mm OD and 15 mm ID Gas supply - Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig - Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve. - Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted. - Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig - Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections - < 407 kPa/59 psig DIN cylinder connections Environmental Specifications System operation - Temperature: 10° to 40°C/50° to 104°F - Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3 - Altitude: -440 to 3565 m/500 to 800 mmHg System storage - Temperature: -15° to 50°C/-5° to 122°F - Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3 - Altitude: -440 to 5860 m/375 to 800 mmHg - Oxygen cell storage: -15° to 50°C/5° to 122°F 10 to 95% relative humidity 500 to 800 mmHg Electromagnetic compatibility - Immunity: Complies with all requirements of EN 60601-1-2 - Emissions: CISPR 11 group 1 class B - Approvals: UL 2601-1 CSA C22.2 #601.1 EN/IEC 60601-1 CE 0197
Tidal Volume: 20-1500ml Working Mode: Semi open, Semi closed or Closed system Oxygen flush: 25L/min 75L/min High light LED display
Anesthesia Machine , Anesthesia workstation with two vaporizers and touch screen display. uses for infant, pediatric and adult application
Ce approved portable anesthesia machine Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley. Jackson or bains absorber is available Specifically designed to accomodate low flow Selectatec-bar and quick change vaporizer mounting device Visible inspiration and expiration valve Could upgrade to oxygen&n2o or oxygen&air flow meter freely Module rack with polyester medical material with superior spray technology, high strength and light weight. With transport case, convenient to take and transport Easy to disassemble and assemble all the components, convenient for clean and maintenance. Medical air compressor Low noise medical air compressor, very stable performance, safe and reliable Air compressor with lcd screen to display output pressure, provide safe, secure and permanent motivation Compact design and easy to transfer Assembled with clean control module, supplying cleaner and safer air to the patients Effective sound-absorbing materials Oil-free compressor with temperature protection Match with various ventilator of international standard in the world Size Weight
ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.