Inline ndir h4 sensor general harateristis
Measurment range 0-4.4 vol.-% (100%ueg)
Temperature and pressure ompensated
Integrated temperature measurement
Rs485 interfae
4-20ma interfae
Inline ndir h4 sensor speifiation
Measuring gas: h4
Measurement range: 0 - 4.4 vol.-% (0 - 100%ueg)
Resolution: 300ppm
Auray: < 2% of the measured value
Response time: < 10s
Heat up time: < 10min
Storage temperature: -20 - +85
Operating temperature: -20 - +65
Operating humidity range sensor: 0 - 99% (not ondensated)
Operating humidity range eletronis: 0 - 85% (not ondensated)
Interfae: rs485
Analogue output: 4 - 20ma
Supply voltage: 10 - 36vd
Power onsumption: < 2w
Long-term stability: < 5% of the measured value per 1 year
IRceL CH4 NDIR CH4 Sensor Description Miniature infrared sensor with on-board EEPROM and thermistor IRceL CH4 NDIR CH4 Sensor Key Features & Benefits: * Integrated thermistor for accurate temperature compensation * EEPROM programmed with sensor specfic performance characteristics * Compact Size IRceL CH4 NDIR CH4 Sensor Technical Specifications * Operating Principle: Non-Dispersive Infra-Red * Measurement Range: 0-5% vol. Methane * Accuracy (-20C to +50C): Within ± (0.1% vol CH 4 + 4% of concentration)?? * Response Time (T90): < 35 Seconds * Supply Voltage: 3-5 VDC, 3.3 V to utilise EEPROM calibration * MTBF: > 5 years
IRceL CH4 NDIR CH4 Sensor Description Miniature infrared sensor with on-board EEPROM and thermistor IRceL CH4 NDIR CH4 Sensor Key Features & Benefits: * Integrated thermistor for accurate temperature compensation * EEPROM programmed with sensor specfic performance characteristics * Compact Size IRceL CH4 NDIR CH4 Sensor Technical Specifications * Operating Principle: Non-Dispersive Infra-Red * Measurement Range: 0-5% vol. Methane * Accuracy (-20'C to +50'C): Within ± (0.1% vol CH 4 + 4% of concentration)â?? * Response Time (T90): < 35 Seconds * Supply Voltage: 3-5 VDC, 3.3 V to utilise EEPROM calibration * MTBF: > 5 years -
Based on Infrared absorbing principle, not only it is well selective to the target gas, but also detecting accurately and stable to gas concentration. The module is compact structure, free maintenance, application is various industry situation.
SH-300-NDTH NDIR Carbon Dioxide Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDTH NDIR Carbon Dioxide Sensor Module Application * CO2 Control for IAQ * Building, Hospital, School * Air cleaner, Air conditioner * Mushroom control, Boiler control SH-300-NDTH NDIR Carbon Dioxide Sensor Module Technical Specification * Measuring Type: Non-Dispersive Infrared (NDIR) * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: FS ±2%, measured value±3% @ 0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: 0 ~ 50'C * Operating Humidity: 0 ~ 95%RH (Non Condensing)
CM1106 Carbon Dioxide Sensor NDIR CO2 Sensor Module Introduction Single Beam(single light source, single wavelength) NDIR CM1106 (Miniature size) can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology(NDIR). It is widely used in IAQ monitor, air conditioner with purifying function, air purifier, ventilation system, automotive and other consumer electronic products etc. CM1106 Carbon Dioxide Sensor NDIR CO2 Sensor Module Features * Advanced non-dispersive infrared technology(NDIR) with independent intellectual property * High accuracy: temperature calibration within whole measurement range * High stability: advanced auto-calibration at background * Small size and compact structure, easy to install CM1106 Carbon Dioxide Sensor NDIR CO2 Sensor Module Application * IAQ monitor * Air conditioner with purifying function * Air purifier * Ventilation system * Automotive CM1106 Carbon Dioxide Sensor NDIR CO2 Sensor Module Specification * Measurement range: 0-2000ppm (extending to 5000ppm, 10000ppm) * Accuracy: auto-calibration within temperature and concentration range * Working temperature: -5'C~50'C * Storage temperature : -20'C~60'C * Working humidity: 0-95%RH (non-condensing) * Signal output: UART-TTL, PWM, IIC * Dimension: 33*19.7*8.9mm * Maintenance: Auto-calibration -
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor MisIR Summary NDIR CO2 Sensor MisIR is a low power (20mW), high performance CO2 sensor. Based on GSS patented solid state IR sensor technology and innovative optical designs, MISIR is configured to meet the requirements of the HVAC and Demand Led Ventilation markets. Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor MisIR Characteristic * Low Power 20mW * Measurement ranges from 0 to 1% * Low noise measurement
High speed carbon dioxide sensor ndir co2 sensor sprintir summary Sprintir is a high speed (20 hz) co2 sensor, ideally suited for applications which require capture of rapidly changing co2 concentrations including metabolic assessment and analytical instrumentation. Fast, accurate carbon dioxide sensor The sprintir carbon dioxide sensor is the fastest, most accurate co2 sensor on the market. A breakthrough in ndir technology, the sprintir uses advanced solid state indium antimonide ledâ??s and detectors to offer a robust sensor with no moving parts, no heated filaments, and incredibly low power requirements. The sensor comes in four versions - from 0% to 100% - all capable of the same high-speed co2 measurement. This makes the sprintir especially useful in biological applications. * high speed sensing (20hz) * measurement ranges from 0 to 100% * 3.3v supply * low power requirement 35mw * flow through adaptor (optional) High speed carbon dioxide sensor ndir co2 sensor sprintir specifications Measurement range: 0-5%, 0-20%, 0-60%, 0-100% Accuracy: â±70 ppm +/- 5% of reading Measurement noise:
MH-Z19B NDIR Infrared CO2 Sensor Module Applications MH-Z19B NDIR infrared gas module is widely used in * HVAC refrigeration * Indoor air quality monitoring. * Smart home appliances * School * Air cleaner MH-Z19B NDIR Infrared CO2 Sensor Module Technical parameters * Main Functions and Features * High sensitivity, high resolution * Low power consumption * Output modes: UART and PWM wave * Temperament compensation, excellent linear output * Good stability * Long lifespan * Anti-water vapor interference * No poisoning MH-Z19B NDIR Infrared CO2 Sensor Module Technical Parameters * Target Gas: CO2 * Working voltage: 4.5~ 5.5 V DC * Average current: < 60mA(@5V) * Peak current: 150mA (@5V) * Interface level: 3.3 V(Compatible with 5V) * Preheat time: 3 min * Response Time: T90 < 120s * Working temperature: 0 ~ 50 deg C * Working humidity: 0~ 90% RH (No condensation)
TS418-1N426 Thermopile Infrared Sensor SPECIFICATIONS * Thermopile IR-Sensor * Filter for NDIR CO2 Gas Detection * Single Element * Very High Signal * Flat Filter * Small Package * Accurate Reference Sensor TS418-1N426 Thermopile Infrared Sensor DESCRIPTION Thermopiles are mainly used for contactless temperature or non-dispersive infrared measurement in many applications. Their function is to transfer the heat radiation emitted from the objects or other infrared sources into a voltage output. TS418-1N426 Thermopile Infrared Sensor FEATURES * Very High Signal * Accurate Reference Sensor * 4.26µm Narrow Band Pass * Small TO-18 package TS418-1N426 Thermopile Infrared Sensor APPLICATIONS * NDIR CO2 Gas Detection