The one step test for hba1c (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine hba1c in human whole blood specimens. Two monoclonal antibodies are employed to identify hba1c specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of hba1c.
Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of hba1c is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The one step test for d-dimer (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunechromatogrphy to determine d-dimer in human plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify d-dimer specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of d-dimer. Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of d-dimer is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The one step test for hs-crp+crp (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine hs-crp+crp in human serum, plasma, whole blood or fingertip blood specimens. Two monoclonal antibodies are employed to identify hs-crp+crp specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of hs-crp+crp. Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of hs-crp+crp is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The one step test for ck-mb/ctni/myo (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine ck-mb/ctni/myo in human serum, plasma, or whole blood specimens. Two set of mixed monoclonal antibodies are employed to identify ck-mb/ctni/myo specifically, resulting in three purplish red streaks appear on the test lines. The color intensity of each test line increases in proportion to the concentrations of ck-mb/ctni/myo respectively. Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of ck-mb/ctni/myo is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. If you need your items by a certain date, please contact us prior to placing your order. Expedited shipping availability may vary. We cannot guarantee that this item can be canceled off of the order or returned once it is placed. Additional information Weight 0.14 lbs Quantity 50/Pack Type Water Test Strips Test Level 10 PPM (Free Chlorine) 10 PPM (Total Chlorine) 240 PPM (Total Alkalinity) 425 PPM (Total Hardness)
H-fabp fast test kit (immunofluorescence assay) is intended for use together with getein1100 immunofluorescence quantitative analyzer (getein1100) or getein1600 immunofluorescence quantitative analyzer (getein1600) to quantitatively determine the concentrations of h-fabp in human serum, plasma, or whole blood specimens in point-of care and laboratory settings. H-fabp fast test kit (immunofluorescence assay) is intended for in vitro quantitative determination of heart-type fatty acid binding protein (h-fabp) in serum, plasma or whole blood. This test is used in the early diagnosis of ami and pulmonary embolism, and monitoring of chronic heart failure.
1. Intended use: The salbutamol residue rapid test card is a rapid, one step test for the qualitative detection of salbutamol in meat samples. The whole time of assay is only approx. 15~25min. 2. Summary: Salbutamol belongs to the group of G-agonists. It can promote animalí»s fat metabollism, and accelerate the growth of animal. However, this is prohibitted. Except for its lipolytic and anabolic effect, salbutamol is used as antiasthmatic and tocolytic agent which has a slacken effect on non-striated musculature. It can remain in animalí»s body and may lead to strong effect to human. If for worse, it may threaten peopleí»s life. Salbutamol is prohibitted for using in most countries. The salbutamol residue rapid test card is a rapid test to qualitatively detect the presence of salbutamol in specimen at the sensitivity of 58g/kg. The major advantage of the one step test device is that the result can be observed easily . 3. Principle: The principle is the antigen-antibody reaction. The one step test device is a competitive immunoassay of which the detector reagent consists colloidal gold particles that is coated with affinity purified anti-salbutamol antibodies. The capture reagent in the assay is salbutamol-protein conjugate, which is immobilised on the membrane of the test device. The specimen migrates over the membrane. The more analyte in the sample, the more effectively it will compete with the salbutamol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent.. If salbutamol in the specimen is above 58g/kg, it will prevent the binding of the detector reagent with the salbutamol immobilised on the membrane, resulting in positive.
Fully automatic chemistry analyzer Discrete automatic, random stat function Online test items: at most 26 testing items 18 sample positions, 26 reagent positions with refrigrated function Throughtput: 200 tests/hour 60 pcs reaction cuvettes Wavelength: 300-800nm, 9 wavelengths 7-step automatic washing, automatic cuvette dry function Easy to operate Compact construction and light weight Dimension:540x420x320mm Net weight:23kgs
Envisys technology is one of the leading manufacturers of environmental chambers in India. We supply a variety of temperature humidity chambers, based on the industry's requirements for various applications including building materials, plastics, composites, metals, electronic components, batteries, etc. To withstand product quality in a variety of environmental testing, we manufacture a wide range of test chambers, Environmental Test Chambers, Thermal Chambers, Salt Spray Chambers, Dust Chambers, Rain Chambers, Thermal Shock Chambers, Altitude Chambers, Walk-in Chambers, Vibration Interface Chambers, UTM Interface Chambers, Temperature Forcing Systems, Industrial Oven / Dryer, Industrial Chiller & Razor Blade Treatment Chamber in Bangalore, India.
A one scientific & laboratory instruments co. Are manufacturer & exporter of all type of laboratory glassware, scientific, surgical, medical, hospital, laboratory, dairy, milk testing instruments & equipments under sparsh brand including chemical, charts, models & slides International standard