Precise cut series Histology Fully Automatic Rotary Microtome - LCD Display with Feather
Touch Keypad, Section thickness adjustable, Cutting/Trimming Mode Fast Forward/Backward
Function, Increase/Decrease Section Thickness, Section Counter/Section thickness display,
Motorized Feed Drive, Coarse feed speed directions (in both direction) around 300μm/s &
900μm/s, Universal specimen clamp, JP Series Disposable knife holder with lateral
displacement feature. Single/multiple stroke sectioning, Sectioning in two speeds, Emergency
brake & safety alarm feature provided.
Technical specifications :
Section/Trimming Thickness Range : 0.5μm-100μm
Trimming Thickness Setting: 1μm-600μm, Minimum Setting Value: 0.5μm
Object feed : 28mm + 2mm
Vertical stroke : 60mm + 10mm
Specimen Orientation: X and Y-axis : universal 80, Z-axis : up to 3600
Max. Specimen size : 50x50mm
Operation : Automatic, Semi-automatic, Weight : 35 kg.
Standard Accessories : Disposable blades high profile PTFE coated pkt of 50 nos.
Optional accessories: Retraction mechanism, calibrated controls for quick orientation of
specimen for re-cut, Standard cassette clamp.
Conventional Manual Rotary Microtome
Advanced Manual Rotary Microtome
Semi Automatic Microtome.
SEMI AUTOMATIC CRYOSTAT MICROTOME Refrigerated cut Series Semi Automatic Cryostat Microtome - Electronic Control System with powerful functions & convenient operation, The cooling system incorporates PID temperature controller and a sealed compressor to ensure quick cooling upto -30C and0 trouble free performance, Large stainless steel chamber permits adequate storage facilities for housing of microtome, Visual display for section thickness indication, temperature & other parameters, Lateral displacement feature provided for blade. UV is used for disinfection, Rapid Refrigeration mode & Specimen retraction function provided (with LCD touch panel) (advance model). Section Thickness Range :1 m-60 m, Trimming Thickness Range :10 m-100 m in 10 m increments, Vertical stroke : 65mm Specimen horizontal feed : 25mm, Motorized coarse feed: 480 m/sec Specimen retraction : 5-75 m in 1 m increments, Specimen Orientation : X and Y- axis : universal 80 Cryo Chamber Temp : -1 to 300C Adjustable. Cooling Downtime to -300C. Max. Specimen size : 35x35mm, Quick Freeze Shelf : < - 050C Chamber Defrosting: Programmable or manual, No. of Freezing Stations: 10. Operation: Semi automatic Standard accessories: High profile blades pkt of 50 nos.blades, freezing medium 120ml, standard chucks, Warranty : 2 years.
This instrument approved by CE certificate, ensure running safety. It with automatic working table, X-Y automatic moving, and Z automatic focus. All the operation steps can be controlled on computer, also can operate by manual.
Main Advantages of Biochemistry Analyzer : 1.New concept and more friendly software. 2.New techniques and spare parts used for much better quality and function. 3.Automatic washing station for both sample and reagent probe. 4.Liquid level detection and collision protection for both sample and reagent probe 5.Reliable cooling system for reagent chamber. 6.Powerful reaction cuvette washing system. 7.ISE module and barcode scanner(option). 8.Lower waste and more environment friendly. 9.New concept test control system available(on request). Clinical Equipment Fully Automatic Biochemistry Analyzer (YJ-250) Clinical Equipment Fully Automatic Biochemistry Analyzer (YJ-250) Model YJ-250 Biochemistry Analyzer Assay Model Random Access with direct reading syatem Method End point,Kinetic,Fixed time,Immunoturbidimetry,1-2 reagent,Multistandard,reagent/serum blank,etc Assay Item 40 assay ISE mould (Na+ ,K+, Cl- /LI*) available on request Throughput 1Reagent 257 tests/hour 2Reagent 150 tests/hour With ISE +120 tests/hour Test Menu T.BILI r-GT/GGT CHO Ca APOB-1/B CHE D.BILI ALP/AKP TG CL APOB CREA TP UREA CK P CK-MB Mg ALB CREA LDH C ASO AFU Lactic Acid ALT/GPT UA a-HBDH CO2 FMN LP(a) AST/GOT GLU AMY LDL-C HDL-C CHE LA TBA ADA HA-CRP PA FE Cu Zn C3 C4 lgG IgM lgA and drug ,toxicity ,etc Sample Position 60 Including standard,control and stat,either serum cup primary tube available Sample Volume 1~100ul,0.1ul/step Reagent Position 40 or 80 (optional) Reagent Volume R1:1~400ul,1ul/step ,R2:1~400ul,1ul/step Reagent/Sample Probe With liquid level sensor,collision sensor,teflon coating and automatic washing station Reaction Time 0~999 seconds
Torque controlled ac/dc electric screwdriver 1 piece can also be ordered
Torque controlled ac/dc electric screw driver 1 piece can also be ordered
Supplier: Fully & semi automatic strapping machine, carton sealing machine, hand operated tools