SO2-B4 Sulfur Dioxide Sensor 4-Electrode
PERFORMANCE
Sensitivity nA/ppm at 2ppm SO2 275 to 475
Response time t90 (s) from zero to 2ppm SO2 < 30
Zero current nA in zero air at 20â?? -80 to +80
Noise* ±2 standard deviations (ppb equivalent) 5
Range ppm limit of performance warranty 100
Linearity ppb error at 100ppm SO2 , linear at zero and 10ppm SO2 0 to -2
Overgas limit maximum ppm for stable response to gas pulse 200
* Tested with Alphasense ISB low noise circuit
LIFETIME
Zero drift ppb equivalent change/year in lab air < ±20
Sensitivity drift % change/year in lab air, monthly test < ±15
Operating life months until 50% original signal (24 month warranted) > 36
ENVIRONMENTAL
Sensitivity @ -20â?? (% output @ -20â??/output @ 20â??) @ 2ppm SO2 70 to 82
Sensitivity @ 50â?? (% output @ 50â??/output @ 20â??) @ 2ppm SO2 95 to 110
Zero @ -20â?? nA change from 20â?? 0 to -10
Zero @ 50â?? nA change from 20â?? 10 to 30
CROSS SENSITIVITY
Filter capacity ppm·hrs 450
H2S sensitivity % measured gas @ 5ppm H2S < 2
NO2 sensitivity % measured gas @ 5ppm NO2 < -160
Cl2 sensitivity % measured gas @ 5ppm Cl2 < -40
NO sensitivity % measured gas @ 5ppm NO < -2
CO sensitivity % measured gas @ 5ppm CO < 2
H2 sensitivity % measured gas @ 100ppm H2 < 0.5
C2H4 sensitivity % measured gas @ 100ppm C2H4 < 1
NH3 sensitivity % measured gas @ 20ppm NH3 < 0.1
CO2 sensitivity % measured gas @ 5% CO2 < 0.1
KEY SPECIFICATIONS
Temperature range â?? -30 to 50
Pressure range kPa 80 to 120
Humidity range % rh continuous (see note below) 15 to 90
Storage period months @ 3 to 20°C (stored in sealed pot) 6
Load Resistor ohm (ISB circuit is recommended) 33 to 100
Weight g < 13
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Dgs-so2 968-038 digital so2 sensor module description Easily add so2 sensing to your iot application with our sulfur dioxide digital gas sensor module that provides a calibrated and temperature compensated output. 0 to 20 ppm so2 sensor with digital output. Dgs-so2 968-038 digital so2 sensor module benefits Low power - 1 mw 1 minute sampling Calibrated & temp. Compensated output Fast response < 30 seconds Simple digital uart interface Integrated t & rh sensors Robust 10-year estimated lifetime Rohs compliant Small form factor Uart to usb adapter provided Lightweight (< 2 oz.) Dgs-so2 968-038 digital so2 sensor module applications Air purification control Air quality monitoring Industrial safety sensing Dgs-so2 968-038 digital so2 sensor module measurement performance characteristics Based on standard conditions 25 âºc, 50% rh and 1 atm Measurement range: 0 to 20 ppm Resolution: 50 ppb Measurement accuracy: 15% of reading, , measurement repeatability, : < â± 3% of reading, T90 response time (100 ppm step), : < 30 seconds,
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Misir is a low power (20mw4), high performance co2 sensor. Based on gss patented solid state ir sensor technology and innovative optical designs, misir is configured to meet the requirements of the hvac and demand led ventilation markets. Low power 20mw Measurement ranges from 0 to 1% Low noise measurement
PCFS-IR2125A level sensor contact type, it is used for tube. The principle is infrared, output signal is analog. When there is no water, the sensor outputs low voltage value; When there is water, the sensor outputs a high voltage signal. The size can be customized. The photoelectric liquid level switch has high precision, low price, high reliability and wide application environment, it is less affected by strong acid, alkali and viscosity. Photoelectric level sensors can be used for higher liquid level accuracy requirements.
As per PN and Model Standard lot size
Sensor The dis include: current sensor, voltage sensor, photo gate sensor, light level sensor, force sensor, micro current sensor, motion sensor, temperature sensor, gas pressure sensor, sound sensor, 1394 interface data line, usb date line and dislab software.
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s
Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s