Unlimited dimmer for LED: Adopt PWN to finalize 2%-100%
Ultra-bright: 100000cd/m2
High uniformity: Even if adjust the brightness to the lowest, the surface without any bright spot or dark areas
Cooling fans ensure the viewing areas does not get hot so there is no danger of damaging films
Meets requirements of EN25580: 1992; ASTM E 1390-90 and ISO 5580: 1995
Supplier: Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,
Services: Buying office, oem, components sourcing, value added services
Buyer: In shell pecan nut, macadamia nut
Unlimited dimmer for LED: Adopt PWN to finalize 2%-100% Ultra-bright: 100000cd/m2 High uniformity: Even if adjust the brightness to the lowest, the surface without any bright spot or dark areas Cooling fans ensure the viewing areas does not get hot so there is no danger of damaging films Meets requirements of EN25580: 1992; ASTM E 1390-90 and ISO 5580: 1995
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile