Temperature and humidity control function, maximum 6 loop of independent step operating function
Alternative operation by maximum 4 compressors and 8 heaters
Backup operating function
Prevention from frequent starting failure occurred by low pressure hunting using low pressure switch in compressor
Successive starting function, pump down function and prevention from restarting function
Control function for cold water, hot water, steam valve, SCR, damper designed for HVAC (4-20mA PID control)
Detection of error in temperature and humidity sensor, alarm function and output of equipment state (cooling and dehumidification and heating and humidification)
Intelligent access controller Intelligent access controller: 1. It can control all kinds of electronic locks. 2. It is simple to connect up, work steady, high-power switch power inside, voltage accommodation wide range, the general system doesn't need impress power, inlay the electric box of 86 serial standards inside, suit to environmental, rainproof, and waterproof, defend the sunshine from direct radiation. 3. Inductive, untouched, prevent wear out, long service life. 4. Controlled by electricity, open quickly. 5. With triple-password-confirming function. 6. Great amount of storage: 900 users, 2000 records. 7. Can choose the remote controller for the device. Notice: The ht2110_1 is online model, The ht2110b_1 is offline model Electric parameters: Input voltage: ac90v~240v
1. Main feature Advanced operation method leads to easy learning and simple manipulation; and the compatibility of operation is available among the instruments differ in the model and function. Provide nearly all of the functions contained by most similar industry automatic controller in the world, and the mature technique made it generally used in various kinds of industrial fields. Provide various models that can meet different needs either in the functions or price. With power supply of 85-264vac or 24vdc and various installation dimensions for users to choose. Adopt digital calibration system for measurement input with measurement input accuracy less then 0.2% f.S., non-linear calibration for common sensors is available in the instrument. Adopt advanced ai artificial intelligence control algorithm, no overshoot and with the function of auto tuning and self-adaptation. Adopt advanced modular structure, equipped with plentiful output specifications, and can satisfy the needs of various applications. This makes it possible to shorten the date of delivery and convenience the maintenance of the instrument. having the predominant performance of anti-interference. 2. Technical specification Input type: (either of below specifications can be used selectively in the same instrument) Thermocouple: k, s, e, r, j, t, b, n Resistance temperature detector: pt100, cu50 Dc voltage: 0f¼5v, 1f¼5v, 0f¼1v, 0f¼100mv, 0f¼20mv, etc. Dc current (external shunt resist needed): 0f¼10ma, 0f¼20ma, 4f¼20ma, etc. Optional: apart from the above-mentioned input type, additional type can be provided upon request.(graduation index is needed)
Cd-x08 series 3 digital temperature controller Feature 1. New algorithm using fuzzy logical pid control 2. Six alarm mode setting freely 3. Tc input, rtd input, voltage input, ampere input 4. Relay output, voltage output, ampere output 5. 3 digit led display Model and parameter 1.How to select input type Rtd Pt100(0-499.9ípc) No need custom-mode; free exchange the input way Tc K(0-600ípc) R(0-1600ípc), s(0-1600ípc)ú¼bú¿0-1800ípcú¬ú¼eú¿0-1000ípcú¬ú¼nú¿0-1200ípcú¬ú¼jú¿0-800ípcú¬ú¼tú¿0-400ípcú¬ Need custom-mode 2.Technical parameters Measuring accuracy Less ía0.5%f.Síal dig Control mode On/off control, pid direct action, pid reverse action Control accuracy ía1ípc Control output Relay output, voltage output 0-10madc output, 4-20madc output Relay contact burden 3a/250vac Power 90-250vac 60hz Anti-interference Iec 3g Carton
Cd-xoo series 4 digital temperature controller with following details. Feature 1. New algorithm using fuzzy logical pid control 2. Six alarm mode setting freely 3. Tc input, rtd input, voltage input, ampere input 4. Relay output, voltage output, ampere output Model and parameter 1.How to select the type Standard signal 0-5vdc input, 1-5vdc input 0-10madc input 4-20madc input Level input is 0-50dvc Rtd Pt100 (0-499.9íµ), gu50(0-99.9íµ) No need custom-made; freee Exchange the input way Tc K(0-600íµ), j(0-800íµ), t(0-400íµ R(0-1600íµ), s(0-1600íµ), b(0-1800íµ), e(0-1000íµ), n(0-1200íµ), l Need custom-mode 2.Technical parameters Measuring accuracy Less ía0.5%f.Síal dig Control mode On/off control, pid direct action, pid reverse action Control accuracy ía1ípc Control output Relay output, voltage output 0-10madc output, 4-20madc output Relay contact burden 3a/250vac Power 90-250vac 50hz/ 60hz Anti-interference Iec 3g Carton
Mainly used in the low voltage distribution switchboard to control and protect power distribution systerm. Its technical index reaches the international advanced standard of that kind of products in 1990s and conforms to criteria for low voltage breaker in iec60947-2
Steam house controller Tv/dvd/vcd/cd function Steam control:max.Power ac220v/3kw Fm function Top light:ac220v/32w or ac12v/12w Background light:ac12v/8w Disinfection:ac12v/5w Telephone receiving(hands-free) Remote control Alarm Intelligent failure detection
BRAND : FUJI TEMPERATURE CONTROLLER PXF9 , PXF4, PXF5, PXF4 SOCKET TYPE ALL SERIES AVAILABLE . Precise control: Achieved a processing speed of 50 ms which is 10 times faster than conventional models. Reading accuracy is also improved from �±0.5% to �±0.2%*. *Comparison under 0â??850�°C range, with RTD. See the Data Sheet for details. Easy-to-see display MVA LCD* which offers high contrast and wide viewing angle Process value is displayed in white *Minimal translucent type vertical alignment liquid crystal display Practical options Simple watt-hour metering function: allows you to monitor energy consumption Operating days alarm: tells you the appropriate time for maintenance work Most compact class in industry 36% smaller (than conventional models) and 58-mm depth shallow body helps downsize your facility Universal input You can use any input among RTD, thermocouples, voltage, current, and mV. The set-up for input change is very easy, only requires parameter change. This allows reduction of maintenance parts
Universal head transmitter anl 181 Universal head transmitter for resistance thermometers (rtd), thermocouples, resistance and voltage transmitters, settable using a pc, for installation in a sensor head (form b), compatible tmt 181. Areas of application Pc programmable (pcp) temperature head transmitter for converting various input signals into an scalable 4 to 20 ma analogue output signal Input: Resistance thermometer (rtd) Thermocouple (tc) Resistance transmitter (ohm) Voltage transmitter (mv) Online configuration using pc with anl 181 configuration kit and pc-software anly win 2000 (compatible e+h readwin 2000) Benefits at a glance Universally pc programmable for various signals Galvanic isolation 2 wire technology, 4 to 20 ma analogue output High accuracy in total ambient temperature range Fault signal on sensor break or short circuit, presettable to namur ne 43 Emc to namur ne 21, ce Ul recognized component to ul 3111-1 Ship building approval gl Online configuration during measurement using setup connector Output simulation Customer specific measurement range settings or expanded setup Technical data Input: Rtd, tc, ohm, mv Output: 4 to 20 ma Supply voltage: 8 to 35 v dc (non-ex-area) 8 to 30 v dc (ex-area) Operation: Pcp (pc programmable) Installation: Sensor head form b Field housing
Intelligent Controller APF7.B02.002C Sold by YOYIK. Deyang YOYIK is a professional production, development, sale of power plant dedicated spare parts and accessories processing company. Through more than 21 years of efforts, the majority of customers have been fully recognized. Yoyik can offer many spare parts for power plants as below: #DF-Intelligent Controller APF7.B02.002C-DF Eddy Current Sensor PR6422/000-121 DG Single phase Dry Type Transformer DG-4KVA 830/230 V oil pressure transducer BH-031009-031 Magnetic Rotational Speed Sensor CS-1 G-065-02-01 displacement sensor potentiometer TDZ-1E-25 Annunciator CJX-14 LVDT Sensor 6000AT Speed sensor CS-1G-D-100-03-02 Differential pressure switch CMS-III Heat Expansion Monitor 8000B/072 TRANSFORMER;CONTROL SG-100VA Eddy Current Sensor PR6423/004-101 thermocouple WRNK2-1223 Bolt electric heating rod ZJ-20-39 analog thermocouple WRNK2-294 LVDT snesor CCH02A.307Z Absolute displacement electronic ruler KLC-100+KM420 magnetic pickup distributor 143.35.19 Hydrogen leakage detection device probe LH1500-B sensor Difrential Expantion TM0120-A01-B00-C06-D50s Temperature controller of drytransformer BWR-906L9 LVDT transmitter XCBSQ-04/300-02-00 AC contactor LC1D4011M5C Eddy Current Signal Converter CON011/915-080 BEARING TEMP SENSOR WZPK2-248 dc pressure switch RC861CZ090HSSYR24DC Current shunt resistror FL2-75mV, 400A Contactor LC1 E09 01380V, 4kW Oil motor stroke sensor HL-3-200-15 eddy current probe CWY-DO-810801 THC card LTA202A Booster Relay YT-300N1 Ignition transformer FC06-SA6 pressure sensor transmitter BH-054011-054 speed sensor CS-3F-M16*1-L70 Speed probe D-100-02-01 Intelligent Controller APF7.B02.002C ZYR-DFYL-2025-2-17