In prevention of two different kinds of fluid from intermixing caused by internal leakage, KAORI precisely designed the D Series solution with the double-stacked plates, to eliminate the possibility of cross contamination. The unique air gap is created between the two plates. Once the internal leakage occurs, the 2nd plate becomes the shield to keep the liquid stay and flow on the same channel through the air gap. Meanwhile, vent holes outside the plate will seep out the liquid as an indication of leakage.
Welcome to A.S Engineers & Fabricators, where innovation meets excellence. We are thrilled to introduce our latest breakthrough: the Heat Exchanger. Engineered with precision and crafted with care, our Heat Exchanger is poised to redefine the standards of heat transfer efficiency in diverse industrial applications. In today's dynamic industrial landscape, optimizing heat transfer is essential for enhancing productivity, reducing energy consumption, and ensuring the reliability of critical processes. With this in mind, our team at A.S Engineers & Fabricators has developed a state-of-the-art Heat Exchanger that promises unmatched performance and reliability. MOC:- SS304,SS316,SS316l,Carbon Steel Strategies by heat Exchanger Fluid Selection: Choose the right fluids based on their thermal conductivity and heat capacity to maximize heat transfer efficiency. Matching the properties of the fluids to the application ensures optimal performance. Flow Control: Implement proper flow control mechanisms to regulate the movement of fluids within the Heat Exchanger. This ensures uniform heat distribution and prevents the formation of hot spots or cold spots, enhancing overall efficiency. Temperature Monitoring: Utilize advanced temperature monitoring systems to continuously monitor the temperature of the fluids entering and exiting the Heat Exchanger. This allows for real-time adjustments to optimize heat transfer performance and maintain desired operating conditions Efficient Heat Transfer Our heat exchanger ensures efficient transfer of heat between two fluids, allowing you to maintain optimal temperatures in your processes Cost-Effective Solution By effectively utilizing heat exchange principles, our product helps you save on energy costs, making it a cost-effective solution for your operations Enhanced Performance With improved heat transfer efficiency, our heat exchanger boosts the performance of your equipment and processes, leading to increased productivity Customizable Designs We offer customizable designs tailored to your specific requirements, ensuring that our heat exchanger seamlessly integrates into your existing systems Durable Construction Built with high-quality materials and precision engineering, our heat exchanger is durable and reliable, providing long-lasting performance in demanding industrial environments Easy Maintenance Designed for easy maintenance and servicing, our heat exchanger minimizes downtime and ensures smooth operation, allowing you to focus on your core business activities
Working Temperature - +200'C ~ - 200'C Max Pressure - up to 45 Bar Thickness - 0.3 mm SS316L, Cu - 99%; SS304 - optional
Brazed plate heat exchanger Bl14 n means number of plates Length (mm): 206 Width (mm): 76 Thickness (mm): 10+2.3n Weight (kg): 0.7+0.06n Channel volume (l): 0.010(n-2) Exchange area (m2): 0.014(n-2) Working pressure: 3.0mpa Testing pressure: 4.5mpa Working pressure: -160grc ~ 225grc Bl14a n means number of plates Length (mm): 190 Width (mm): 80 Thickness (mm): 10+2.3n Weight (kg): 0.9+0.06n Channel volume (l): 0.010(n-2) Exchange area (m2): 0.014(n-2) Working pressure: 3.0mpa Testing pressure: 4.5mpa Working pressure: -160grc ~ 225grc
Brazed plate heat exchanger Bl20 n means number of plates Length (mm): 310 Width (mm): 76 Thickness (mm): 10+2.3n Weight (kg): 1.0+0.08n Channel volume (l): 0.018(n-2) Exchange area (m2): 0.020(n-2) Working pressure: 3.0mpa Testing pressure: 4.5mpa Working pressure: -160grc ~ 225grc
Brazed plate heat exchanger Bl26 n means number of plates Length (mm): 325 Width (mm): 111 Thickness (mm): 10+2.35n Weight (kg): 1.3+0.13n Channel volume (l): 0.025(n-2) Exchange area (m2): 0.026(n-2) Working pressure: 3.0mpa Testing pressure: 4.5mpa Working pressure: -160grc ~ 225grc
Brazed plate heat exchanger Plate material: aisi316l/304c Connection material: aisi304 Brazed material: nickel/copper Max design tempt: 150grc/225grc Min design tempt: -160grc Max design pressure: 30barg/45barg Advantages of brazed phe: Compact structure and easy installation Small consumption of water Low scaling coefficient Light in weight and durability
Industrial equipment Brazed plate heat exchanger is a new type of high-efficiency heat exchanger made of a series of metal sheets with a certain corrugated shape stacked and brazed. Thin rectangular channels are formed between various plates, and heat is exchanged through the plates. Compared with the conventional shell and tube heat exchanger, its heat transfer coefficient is much higher under the same flow resistance and pump power consumption, and it has a tendency to replace the shell and tube heat exchanger within the applicable range. Applications: Refrigeration: used as condenser and evaporator b. HVAC: intermediate heat exchangers used in conjunction with boilers, intermediate heat exchangers in high-rise buildings, etc. c. Chemical industry: soda ash industry, ammonia synthesis, alcohol fermentation, resin synthesis cooling, etc. d. Metallurgical industry: heating or cooling of aluminate mother liquor, cooling of steelmaking process, etc. e. Machinery industry: cooling of various quenching fluids, cooling of reducer lubricating oil, etc. Design Parameters Flow range: 1-2000 m3/h Working pressure: vacuum-8.2MPa Operating temperature: -195-538C Interface size: 1"-DN300 welding, flange, thread and other connection forms Corrosion resistance: Welding seal without rubber gasket, choice of various metal and alloy materials, super corrosion resistance, longer service life. Application field: Crude oil, natural gas purification and chemical products; chemical industry; pharmaceutical and specific chemicals; injection control systems; HVAC, district heating, thermal power plants; food processing; cooling tower heat recovery Process requirements Pickling temperature: Raising the pickling temperature is conducive to improving the descaling effect. If the temperature is too high, it will aggravate the corrosion of the pickling solution to the heat exchanger plates. Through repeated tests, it is found that the pickling temperature should be controlled at 60. 2) Concentration of pickling solution: According to repeated tests, the pickling solution should be prepared according to the concentration of formic acid 81.0%, water 17.0%, buffer 1.2%, and surfactant 0.8%, and the cleaning effect is excellent. 3) Pickling method and time: The pickling method should be carried out by a combination of static soaking and dynamic circulation. The pickling time is static soaking for 2h first, and then dynamic circulation for 3~4h. During the pickling process, samples should be taken frequently to test the pickling concentration. When the difference between the two adjacent test concentrations is less than 0.2%, the pickling reaction can be considered to be over. 4) Passivation treatment: After pickling, most of the scale and metal oxides on the surface of the plate heat exchanger will be dissolved and fallen off, exposing new metal, which is very easy to corrode. The sheet is passivated.
Brazed Plate Heat Exchanger is small, light and compact. It does not need gaskets.Instead, it is brazed together using cooper to give a strong, compact construction.This heat exchanger is especially suitable for pressure up to 50 bar and temperatures from -196 to +550.What are the advantages of Brazed Plate Heat Exchanger? High heat transfer efficiency Compact structure Easy installation Easy Deinstallation DurabilityTable. Parameters of HFM Brazed Plate Heat Exchanger Model NoWidthHighthThicknessHole Center DistanceMax PressureMax Flow RateWeightHFQ10762069+2.3n172*421/3/4.58.00.7+0.06nHFQ15801909+2.3n154*401/3/4.58.00.7+0.06nHFQ25A783189+2.3n282*423/4.58.01.0+0.08nHFQ25B863159+2.3n269*403/4.58.01.0+0.08nHFQ3011131010+2.36n250*503/4.5181.3+0.12nHFQ3512430413+2.4n250*703/4.5182.2+0.16nHFQ3612228211+3.1n227*523181.88+0.104nHFQ50A11152510+2.35n466*503/4.5182.6+0.19nHFQ52B11152510+2.35n466*503/4.5182.6+0.21nHFQ60A11952610+2.24n470*633/4.5182.379+0.194nHFQ60B11952610+2.24n470*633/4.5182.379+0.194nHFQ90A19161611+2.35n519*923/4.5427.8+0.36nHFQ90B19161611+2.72n519*923/4.5427.8+0.44nHFQ10024849610+2.15n405*1573/4.5426.5+0.37nHFQ125A24652813+2.36n456*1743/4.5427.2+0.52nHFQ125B24652813+2.36n456*1743/4.5427.2+0.52nHFQ18030769613+2.76n567*3071.5/2.110010+0.51nHFQ21032173813+2.7n603*1881.5/2.110013+0.75nHFQ210A32173813+2.7n603*1881.5/2.110013+0.75nHFQ23032273913+2.55n631.7*205.23/4.510013+0.82nHFQ600429139822+2.78n1190*2201.5/2.130031.8+1.73n