STANDARDS : EN 196-3,ASTM C187-C191,AASHTO T129-T131,BS 4550
Movements along X Y Z axes
Up to 30 different test types may be programmed and over 1000 tests may be memorized. PC Port
Initial and fi nal setting time (in 0.1 mm)
Automatic cleaning of the needle
Automatic stop and storage of measurements for up to 50 tests
Plunger for initial consistency
Thermostatic baths (optional)
Display for data input and diagram/test report
Printer for final test report and diagram
RS 232 serial port for PC connection
Moulds and further needles have to be ordered separately, according to the various standards
Power supply: 220 V, 50 Hz, single phase
Dimensions: 355 x 620 x 580 mm Weight: 40 kg.
Dimensions: 355 x 620 x 580 mm
Weight: 40 kg
Feature It can automatically record the temperature while the deformation of the specimen reaches the preseting value and the test of HDT/VICAT ;it can be easily performed respectively by replacing the header of the loading rod. Weight 426 kg Dimension 140X65X180 cm