Vg-led0503
Double heads
5+3 lighting unitsIllumination(lux)
160000+120000
Consumption200w+200w/12v
Weight 70kg
Package size1020mm*740mm*700mm
Gross weight95kg
Technical data:
Color temperature3500-5000k
Diameter of spot150-300mm
Illumination depth>800mm
Light adjusting steps1-9
Restore color index95-98
Shadowless proportion98%
Led life>50000h
Up doctor-head temperature<1degree
Power supply110-240v 50/60hz
Ceiling minimum height2400mm
Battery back-up 12vOptional
Advantage:
1 adjustable color temperature and illumination
2 own iso, ce certificate
3 battery back-up is optional
4 with remote control
Characteristics:
1.Renew operation irradiation parts rapidly and improves doctors' working environment
2.Save energy, only 1/10 as the normal incandescent lamp and 1/2 as the halogen lamp
3.Color temperature can be adjusted from 3500 to 5000k randomly
4.Led life is 50 times longer than halogen lamp
5.Illuminance equality, high shadowless rate, high definition to improve doctor's working efficiency
Packed in woonden case, the size is 1020mm*740mm*700mm
1. Supply this sink fully automatic control by sensor ,kneecontrol,foot-control 2. Seamless-welding surface,whole steel framework is reliable and strong. 3. The sensor tap is convenient for the user 4. Used for operating room and hospital 5. Equipped with the lamp system ,automatic sensor tap,water outflow sifter ,mirror and elegant outlook. 8. Power: 220V, 60Hz. 9. All these sinks could be made as per your special requirement. -Electric Heating Machine -Automatic Soap Sensor -Automatic Disinfector Sensor -Cleaning Brush & Box Taps 1 unit
Shadowless operating light combination provides the superior performance for all kinds of surgeries. Compact, light weight and sealed dome made of aluminium consists of glass dichroic reflector to provide cool, bright and homogenous illumination. The use of dichroic glass reflector and athermanous glass filter in combination reduces the emitted ir to a minimum and provide the cool and color corrected light at surgical site and for the surgical team. Advanced suspension arm design, providing smooth, extensive coverage Available as wall, mobile, ceiling mount with single, dual or triple lamp heads
Ethicon is a well-known medical device company, and Harmonic devices are commonly used in surgical procedures for cutting and coagulating tissue. Harmonic devices use ultrasonic technology to provide precise and controlled cutting and hemostasis during surgery. Here are some general features that you might find in a Harmonic device, such as the ETHICON HARMONIC FOCUS SHEARS: Ultrasonic Technology: Harmonic devices use ultrasonic vibrations to cut and coagulate tissue simultaneously. Focused Energy: The "Focus" in the name may indicate a focus on delivering energy precisely to the target tissue. Handpiece: Ethicon Harmonic devices typically consist of a handpiece that the surgeon operates during the procedure. Blade Design: The shears are likely to have a specific blade design optimized for cutting efficiency. Application: Harmonic devices are often used in various surgical specialties, including general surgery, gynecology, and urology.
Luminance:12, 000 Color temperature:4300k plus or minus 500k Sport diameter:160 ~280mm Lllumination depth :greater than or equal 600mm Light-adjusting mode:eight grade dimmer system Temperature at surgeon's head :less than or equal to 2 degrees Color indcatoin index:greater than or equal 97% Power supply:220v plus or minus 22v 50hz plus or minus 1hz Input power:220w Bulb of power(w):150 Lowest herght of installation 2900mm
This operation table is an electric controlled¼ mechanical driven multi-purpose operation table« the most remarkable features of this operation table include easy operation¼ long service life¼ and long maintenance free period¼ which can be widely employed for operation in different parts of the body« 1. Dimensions of table : 2000(l) ß(w)500mm 2. Height of bed surface: minimum height :650 maximum height :900 3. Before and after inclination of bed surface : front inclination:25 back inclination :25 (electric) 4.Left and right inclination of bed surface :left inclination :20 right inclination :20 (electric) 5. Backplane fold angle : rise 80 lower25 (electric) 6. Head section movementrise 45 lower90 (manual) 7. Leg section movementrise 0 lower 90 (manual) 8. Lumbar bridge movement height :0~120 (manual) 9. Power supply voltage ac 220v /50hz or 110v/60hz
1/Driven by imported Electric-Hydraulic system with advanced backup power,suitable for General surgeries 2/ The tabletop framework is molded aluminum casting. The base cover is made of 304 stainless steel 3/Could use with C-arm and X-ray Model No:JQ-01B-1 electric hydraulic surgical table 1/Table size ( mm)L2000*W500*H750 2/ Table lifting height750mm-1050mm 3/ Lean forward22 ï 4/ Lean backward25 ï 5/ Lean left20 ï 6/ Lean right20 ï 7/ Back board folded down 35 ï 8/ Head board folding up45 ï 9/ Head board folding down90 ï 10/ Leg board folding down90 ï 11/ Lengthways slide range295mm
Elbow Joint Splint (AJY-S12) It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint. 448*260*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Achilles tendon dorsal splint (AJY-S11) It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot. 442*247*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb plate (tubular type) AJY-S03 For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation. 210*145*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy