PERKINS diesel gensets
Diesel engine:
rated power:36-1640KW,
four stroke,
water cooling,
1500RPM;
Alternator:
3 phases and 4 wires,
rated voltage:400/230V,
frequency:50HZ,
COSf+:0.8,
AVR
Perkins engine 4008 2011 model coupled with leroy somer 1010 kva with auto syce panel
Supplier: Perkins diesel genset, cummins diesel genset, MTU diesel genset, volvo diesel genset and chinese brand diesel generator
Power Generation NEF45 TM1 NEF45 TM2 NEF67 SM1 NEF67 TM2 NEF67 TM3 NEF60 TE2 CURSOR 78 TE2 CURSOR 13 TE1 CURSOR 13 TE2 VECTOR8 TE1
Characteristic of generator set 1.The design manufacture and test of the engine unit fully comply with national standard GB/T282097; 2.Take unified charge of the design, manufacture and test before delivery of the generator set; 3.Equipped with PERKINS engine ,with advanced technology ,reliable performance and long service life; 4.The excitation system of the generator can make the generator set to bear any twinkling loading and can get restored quickly from frequency fluctuation; 5.The low reactance design of the generator has made extremely low wave form distortion under non-linear load ,and has good motor starting ability; 6.PERKINS Corporation provides quality assurance to all series of its products; 7.CPERKINS Corporation has established a professional service network all over the country ,and provides 24 hours after sale service and supply of parts for clients.
Perkins diesel generator 100kw perkins diesel generator Model: cd-p 100kw (open frame type) Power by perkins lovol engine Continuous power (50hz): 100kw/125kva Stanby power(50hz): 110kw/137.5kva Engine model: 1006tag Engine power (50hz): 121kw Speed: 1500rpm Engine configuration: 6-cylinder in line. 4-strokes. Engine cooling mode: turbocharged air-to-air charge cooled Speed control system: mechanical speed controller, electricity-magnet valve control switch(optional) Start model: 24v direct current start Engine filter system: dry air filter type, fuel filters, lube filter. Engine total displacement: 5.99l Compress ratio: 17.5: 1 Bore stroke: 100 127 Specific fuel consumption: ín 208g/kw. H Lubricating oil consumption: ín 1.4g/kw. H Oil capacity: 19l Alternator model: brushless 100kw Alternator power: 100kw/125kva Rated voltage/frequency: 380v/220v 50hz Power factors: 0.8lag Phase: 3-phase & 4 line Stable voltage regulator: ín ía 3 Insulation class/protection grode: h class/ip 23 Dimension: 2200 900 1700 with base fuel tank Weight: 830kgs
Perkins is one of the world??s leading diesel engines manufactures since 1932, nearly 400,000 units for one year and refer to the products are : 100, 3.152, 4.236, 1000, 1300, 2000, 3000 and 4000 series quickly occupied the Chinese market for the full specification, good structure, reliable performance, easy maintenance, low exhaust gas, long period maintenance. In the autocar, contruction, agricultural, industrial and marine markets, major original equipment manufacture choose perkins engines because of its fuel, nature gas elding for reliable and durable use. Plywood
Genset model: hhp100 Rating power:80kw/100kva Stand-by power: 88kw/110kva Dimension: soundproof type-3200x1130x1650mm Fuel tank capacity(skid base fuel tank): Soundproof type-260l Engine:perkins Model:1006tg2a Governor type: electronic Speed: 1500rpm rated power: 102kw Cylinder number and config.: inline, 6 Displacement: 5.99l Aspiration: turbocharged Cooling system: water cooled Lub.Oil capacity: 16.1l Alternator: stamford Model:uci274fs1 rating power: 80kw Power factor: 0.8 Number of bearing: single Voltage: 400/230v Voltage regulation: +/-1% Frequency: 50hz Insulation class:h Protection: ip22 Excitation system: brussless, avr Connection type: 3 phases, 4 wires, "y" type Dimension: 3200x1130x1650mm Weight:2100kgs
Perkins generator has small volume ,light weight, reliable performance ,low consumption. Alternator Engine can be coupled with A.C. synchronous brushless alternator( new-style designed by ourselves, with update international technology). It can also be matched with STAMFORD, LEORY SOMER, MARATHON alternator according to customersâ?? demand. 1. Standard control panel, including voltmeter, fequency meter, ampere meter,water temperature gauge, oil temperature gauge, oil pressure gauge, AMF control module, oil level indicator, emergency button, preheating button, battery voltage gauge, hours running counter for protection and tranfering. 2. It can be with ATS electric control cabinet, including circuit breaker, LCD or LED auto controller, indicating lamp, transfer switch, etc.. Automatic transfer switch (ATS) uses update technology, which can be automatic control for on-off electricity, remote monitoring, automatic parallel operation,etc.
Perkins generator has small volume ,light weight, reliable performance ,low consumption. Alternator Engine can be coupled with A.C. synchronous brushless alternator( new-style designed by ourselves, with update international technology). It can also be matched with STAMFORD, LEORY SOMER, MARATHON alternator according to customersâ?? demand. 1. Standard control panel, including voltmeter, fequency meter, ampere meter,water temperature gauge, oil temperature gauge, oil pressure gauge, AMF control module, oil level indicator, emergency button, preheating button, battery voltage gauge, hours running counter for protection and tranfering. 2. It can be with ATS electric control cabinet, including circuit breaker, LCD or LED auto controller, indicating lamp, transfer switch, etc.. Automatic transfer switch (ATS) uses update technology, which can be automatic control for on-off electricity, remote monitoring, automatic parallel operation,etc.