Replacement valve plate service kit for copeland 3d models, with valve plate
Cages
Scp part: 20-3d-vpsk
Replacement valve plate kit assembly for copeland 3d delta reed style Compressors PART NO: 20-3DR-VPKT
13-6E-VPKT Replacement valve plate assembly for 06e models, oem ref: 06ea660-106, Non-unloading, old style, 8 round discharge ports. (Parts not shown include all necessary components for the complete VP assembly)
50-J-TPLT & Gasket Phenolic Terminal plate replacement, fits york j models, a,b,c,d,e,f design, OEM REF: 025-19978-000 (GASKET INCLUDED)
Valve plate assembly, high efficiency, for carrier 06e models, 8 oval discharge Ports, OEM: 06EA660-143 (Includes Gaskets)
Refrigerated air dryer Refrigerated impressed air dryer 1). Air-cooling refrigerated air dryer Inlet temperature: Normal inlet temperature45º High inlet temperature80º Cooling method: air-cooling Ambient temperature: 38º Design dew point: 1.7º Refrigerant: r-22 Inlet pressure: 0.2~1.0mpa Pressure drop: 0.02mpa 2). Water-cooling refrigerated air dryer Inlet temperature: Normal inlet temperature: 45º High inlet temperature: 80º Cooling method: water-cooling Design dew point: 1.7º Refrigerant: r-22 Inlet pressure: 0.2~1.0mpa Pressure drop: 0.02mpa Cooling water inlet temperature: 32º Cooling water inlet pressure: 0.2~0.4mpa
Holysun offers two types of Refrigerated Air Dryer: 1). Air-cooling refrigerated air dryer Inlet temperature: Normal inlet temperature: less than 45 celsius degree High inlet temperature: less than 80 celsius degree Cooling method: Air-cooling Ambient temperature: less than 38 celsius degree Dew point: 2~10 celsius degree Refrigerant: R-22 /R-134a Inlet pressure: 0.2~1.0MPa Pressure drop: less than 0.02MPa 2). Water-cooling refrigerated air dryer Inlet temperature: Normal inlet temperature: less than 45 celsius degree High inlet temperature: less than 80 celsius degree Cooling method: Water-cooling Dew point: 2~10 celsius degree Refrigerant: R-22 /R-134a Inlet pressure: 0.2~1.0MPa Pressure drop: less than 0.02MPa Cooling water inlet temperature: less than 32 celsius degree Cooling water inlet pressure: 0.2~0.4MPa
Supplier: Air dryer, Refrigerated Air Dryer, Heatless Air dryer, Nitrogen Generator, Oxygen generator, Zero air loss drain valves
Services:
Replacement copeland k model std. Bearing Main bearing replacement for copeland k models, 2 used per compressor, Finished bore, OEM# 035-0059-00, 204-2802 (NEW)
Replacement for York Z Model 74MM Piston OEM: 065-25239-000 / CMP: PST-1172 / Bradleys: 2870