Pass box adopts the sand light stainless steel inside,which is flat,neat,wearable.The surface material of pass box is cold rolled steel or stainless steel.
Doors in two sides with machinery or electronic interlock device makes two doors can¬H be in the open state at the same time,it prevent the cross-infection between clean zone and unclean area.
OEM is available.
Pass box is used to transfer the material from lower cleanliness area to higher cleanliness area or vice-versa in the classified area and also known as the hatch. Pass box works as a barrier between two cleanliness level areas. A pass box, which is also called a transfer hatch or SAS pass (sterile access system), Static pass boxes are used to transfer materials between two rooms of equal cleanliness levels and are designed for minimal personnel movement while dynamic pass boxes are used to transfer materials from uncontrolled to controlled environments. Dynamic pass box works like an airlock or laminar air flow unit. We design and manufacture static and dynamic Pass Box and other clean room environment furniture as per the design and specification of our clients
DYNAMIC PASS BOXES - Dynamic Pass Box (aka Pass Through Box or Clean Pass Box) is primarily designed to minimize man and material movement between different classified areas thereby minimizing the chances of cross contamination. Pass Box is an essential equipment for any manufacturing or research facility which requires maintaining the integrity of different classified areas.
Supplier: Fans Filter Units, Laminar Flow Hood, Vertical Flow Hood, Laminar Flow Clean Bench , Air Shower , Clean Wardrobe , Clean Doors, Safety Clean Cabinet , Pass Thru, Pass Box, Laminar Flow Ffu , Ffu
Buyer: Aluminum Plate , Zinc Plate , Stainless Steel Plate , Motor , Engine
Characteristic 1.Clean bench (level) is adopted the super thin air filter without clapboard to minimize the size of structure. The clean bench is matched stainless steel table-board and glass on sides. 2.It makes the workaround roomy and bright. We adopt send-off wind system that the air velocity is adjustable by touch the switch lightly,which makes the wind speed perfect. 3. The prefilter that with big wind speed is convenient to take town. It is not only protect the HEPA filter's life and also ensure the wind velocity. 4.Level air current,opened desk type,and convenient operation. 5. Customized design is available. standard export packing
Laminar air flow information We have CE,ROHS,ISO9001,ISO14001 for it. KLC series mini-type air flow laminar box, It is used for the partical high clean requirement in workshop and lab. Characteristic 1).It is adopted the super thin air filter without clapboard to minimize the size of structure. The air flow laminar box is matched stainless steel table-board and glass on sides. 2). It makes the workaround roomy and bright. We adopt send-off wind system that the air velocity is adjustable by touch the switch lightly,which makes the wind speed perfect. 3).The pre - filter that with big wind speed is convenient to take town. It is not only protect the HEPA filter ' s life and also ensure the wind velocity. 4).Level air current, opened desk type, and convenient operation. 5) Customized design is available for laminar air flow. Packing is plywood.
Supplier: Inert atmosphere glove box, isolators, fume hoods,bio safety cabinets, pharma equipment, design of machine, lab equipment, clean room products, pass boxes lab furniture, stainless steel products, kitchen equipment, industrial, mechanical, electrical spares, and fabrication, biological safety cabinets, fume hood, inert atmosphere glove box, chemical industrial glove box, hoppers, steel tools box, industrial work bench, gaskets, lab furniture, steel rack , nuts and bolts, control valve, shrink tunnel, flat belt conveyor, heavy industrial fabrication, plantery mixing machine, pressure vessels, high vacuum furnaces, boilers, etc., refrigeration equipment
A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height. Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to: protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes) protect the product or experiment (biosafety cabinets, glove boxes) protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream) Secondary functions of these devices may include explosion protection, spill containment, and other functions necessary to the work being done within the device. Fume hoods are generally set back against the walls and are often fitted with infills above, to cover up the exhaust ductwork. Because of their recessed shape they are generally poorly illuminated by general room lighting, so many have internal lights with vapor-proof covers. The front is a sash window, usually in glass, able to move up and down on a counterbalance mechanism. On educational versions, the sides and sometimes the back of the unit are also glass, so that several pupils can look into a fume hood at once. Low air flow alarm control panels are common, see below. Fume hoods are generally available in 5 different widths; 1000 mm, 1200 mm, 1500 mm, 1800 mm and 2000 mm.[1] The depth varies between 700 mm and 900 mm, and the height between 1900 mm and 2700 mm. These designs can accommodate from one to three operators. For exceptionally hazardous materials, an enclosed glove box may be used, which completely isolates the operator from all direct physical contact with the work material and tools. The enclosure may also be maintained at negative air pressure to ensure that nothing can escape via minute air leaks.
inert atmosphere glove box-This system is working as inert atmosphere work station controlling moisture, oxygen, and pressure etc. and work with feedback control system, that works for packing various types of test kits,. This box is a multiple operator system six people can work by sitting opposite side and 13 glove ports ,size was 4000mm L x 1200mm W 900 mm H
Box dimension - 1000mm x 750mm x 750mm Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Filtration HEPA : particles Glove Ports - Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter - 0.3 micron Dust filter. HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each Shelves - Height Adjustable, Acrylic Stainless Steel shelves Three/ Yes Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes Box Lamp -One front mounted fluorescent lamp one inside Yes Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. PLC Program Logi Control with integrated control with external display unit 10 One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?Â2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support - Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.