Features:
1 Current: 250A-3150A
2 Protection degree: IP54
3 High temperature withstand capability up to 80 degree Celsius
4 fire retardant Class-H-Epoxy insulation
Competitive Advantages
1 Well and High Quality Control
2 Prompt Delivery
3 Customer's Design and Logo are Welcome
4 Competitive Prices
5 Small Order Acceptable
6 ODM Accepted
7 OEM Accepted
8 Packaging Detail Standard export packaging or customerized packaging
Besides the features of insulated busway, it has good fire-proof feature. Adopt excellent copper bar as conductor and fire-resisting material as insulation layer and enclosure that make it be able to work continuously without interruption when temperature rise to 80 degree celsius.
Standard export packaging or customerized packaging.
Features: 1 Current:300A---6000A 2 Protection degree:IP54 3 sandwich-type compact structure design 4 Low impedance 5 Low voltage drop 6 High dynamo thermal stability. Description: The reasonable sandwich-type compact type structure design keeps for a total length and increases system dynamo thermal stability which makes busway have the low impedance and low voltage drop features. Note: It is strictly prohibited that there is water enter enclosure and conductor after installation, thus anti-water hydrant have to be added on the well-hole. PE grounding conductor is extremely important for safety if big current is required. Both economic enclosure earthing configuration and dedicated PE conductor is available for customer. But the section surface of PE grounding system have to exceed 50% that of phase conductor. CCX-II busway adopts complete closed structure with max protection degree IP54. 100% metal enclosure can be used as shortest and reliable grounding system to guarantee operation safety. Vertical installation is first choice for straight busway but horizontal installation is available according to requirements. The standard length of every section busway 6m. Reasonable design of connector makes both side outline and top outline available. Inner extensive ball cushion inside sides board makes it have average pressure and anti-vibration features. Same specification connectors can be exchanged, which make it easy and quick for installation and disassemble. Adopt steel high-strength bolt and the recommended torque value is 80-108N.m Adopt single bolt design make it easy and quick for installation Professional anti-over turn design can avoid incorrect phase connection. Expansion design can eliminate linear expansion without effect electric conductivity and mechanical strength. Special double-bolt design makes it easy to tight connector without wrench. Plywooden case.
Features: 1 Current range: 100A¡ª5000A 2 Working voltage: 400V 3 Protection degree: IP42 4 Low voltage drop 5 High dynamic stability 6 Comply with GB7251-97 and IEC439.2. Description: A new type of busway designed and developed on the basis of traditional cable mainly used in low-rise building and multi-layer factory etc. Comply to GB7251-97 and IEC439.2. Note: safety factor is lower than air insulation type and has no moisture-proof feature. And its life-span is short. Plywood case.
SFEX CT Manteau, also called the Cable Tray Manteau, is very efficient in extinguishing the initial fire suppression with immediate responses in case of fire because when a micro capsule for fire extinguishing reacts to a certain temperature and flame, it automatically disperses extinguishing agents. It\'s based on a cooling fire extinguishing method, shows an excellent characteristic of being able to extinguish a fire completely with an immediate response at the time of initial fire if you cover it over the electric power line. SFEX Solution : SFEX CT Manteau / SFEX AP Tape 1. Horizontal Section Fire : Access Floor, Cable Pit, and Cable Tray Installation and How It Works 1. Cover the SFEX CT Manteau. 2. Prevent the spread of fire with extinguishing/flame retardance properties 2. Vertical Section Fire Installation and How It Works 1. Wind the SFEX AP Tape on the cable. 2. Prevent the spread of fire with extinguishing/flame spread prevention properties Test Result : AP Tape Test Item Test Standard Unit Test Result Flame test of vertically placed cables The carbonization length should not exceed 2.5mm from the bottom edge of the burner - Do not exceed (carbonization length: 0.6m) During installation, photograph after installation *Test Information Test Facility Standard : KS C IEC 60332-3-10 : 2003(Compliant) Volume of nonmetallic material(L) per meter of test specimen : 1.5 (volume of nonmetallic material for finished cable, not including AP Tape) Number of test pieces : 5 Number of tiers : 1 Number of burners : 1 Position of test piece : Spatial type Flame application time (minutes) : 20 AP Tape installation method : AP Tape in 0.6/1 kV TFR-CV 4C 35 from the height of burner to the top 10cm gap between AP Tape and 20cm length of AP Tape
FRP cable trays at INDO are manufactured from Glass Armored Thermoset fireretardant resins Available in different range applied for ideal locations where metallic systems get easily corroded INDO FRP Cable Tray system meet stringent Fire Retardant requirements It provides advantages like Anti Corrosion High Strength No Earthing UV Resistant Good Electrical Insulator Low thermal conductivity etc
Application :- This is a premium product of electrical wires from \'JPCL\'. These cables are ideal for wiring in residential and commercial complexes, high-rise buildings, hotels, hospitals, schools, colleges, etc. (where the density of people is high). During a fire, these cables not only emit less smoke and toxic hydrochloric acid gas but also retard the spread of fire enabling those trapped inside to escape safely. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance resulting in power saving. These wires are insulated with a special grade PVC compound formulated and manufactured in-house only. The insulation is far superior in terms of critical oxygen and temperature index as well as in light transmission and acid gas generation. The skin coloration offers high insulation resistance and long life. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.75, 1.00, 1.50, 2.50, 4.00 and 6.00 Sq. mm Color Codes : Red, Yellow, Blue, Black and Green (For Earthing) Specification : IS:694 Packing : In 90 meter coils in attractive cartons
POWER CABLES Fire Resistant & Flame Retardant Cables Please contact us for for details catalogue
Flexible fireproof cables are composed of copper stranded wires, mineral compound insulation, and mineral compound sheaths. This kind of cable has non-combustible, smoke-free, non-toxic and fire-resistant characteristics. The structure of the flexible mineral insulated cable adopts a flexible structure and materials that are made of mineral compounds, which make up for the defects of hard structure, flammability, and toxicity. It also has some advantages that other cables cannot have, such as: fire resistance, large current carrying capacity, Impact voltage resistance, mechanical damage resistance, halogen-free, non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high temperature resistance, low cost, etc. Flexible fireproof cables have an important role in protecting lives, materials, and information security. They are used in trunk lines, fire lines, escape rescue systems, such as emergency lighting, fire monitoring, alarm systems, elevator systems, smoke exhaust systems, and control lines, etc. Flexible fireproof fireproof cables used in trunk lines, fire lines, escape and rescue systems, such as emergency lighting, fire monitoring, alarm system, elevator system, smoke exhaust system, and control lines, etc. Flexible fireproof fireproof cables used in Public buildings: high-rise buildings, underground buildings, hotels and restaurants, hospitals, schools, business centers, government affairs centers, department stores, large supermarkets, logistics warehouses, financial institutions such as banks, securities and insurance, post and telecommunications centers, power control rooms, substation rooms, museums, memorials and other historic buildings. Flexible fireproof fireproof cables used in Infrastructure: airport terminals, stations, hub centers, ports, subway systems, Bridges, tunnels. Flexible fireproof fireproof cables used in Industry: coal mining, coal chemical industry, oil field mining, petrochemical industry, oil refinery, metallurgical industry, iron and steel industry, shipbuilding industry, aerospace, electric power industry, pharmaceutical industry, glass industry, paper industry, military system. Flexible fireproof fireproof cables used in Fire prevention, explosion prevention, high temperature places: oil depot and gas station, natural gas transmission and compression station, garden landscape, historic sites, wood structure buildings
The special explosion-proof cable is composed of conductor, insulation, high-strength braided explosion-proof reinforcement layer, explosion-proof armor layer and antistatic outer sheath. According to the different needs of customers, the insulation layer is divided into inorganic mineral insulation, rubber insulation and plastic insulation. Under the protection of the explosion-proof reinforced layer and explosion-proof armor, the special explosion-proof cable can withstand the destructive force of 55 kg of TNT explosives within a certain distance. At the same time, the anti-static outer sheath can effectively guide the static electricity generated by the friction between the cable and the non-insulator, prevent the fire, explosion and other safety accidents caused by static electricity in military facilities, and perfectly solve the technical problem that the "cable static bundle" is easy to detonate. The special explosion-proof cable also solves the current national defense combat readiness facilities, such as ammunition depots, hangars, military ports, caverns, military and civilian airports, tunnels, military exercise bases, large-scale power, chemical, coal, subway hazardous chemical wharf and other electrical equipment facilities Safety issues of explosion-proof system or unit power transmission. Inorganic mineral insulated explosion-proof cables also have: low-smoke, halogen-free, flame-retardant, low-toxicity, fire-proof and other combustion characteristics, and have passed the most demanding C, W, Z and BS8491 fire tests in the British BS6387. At the same time, the cable has good flexibility, Features such as strong compression resistance and long manufacturing length. Special explosion-proof cable is suitable for ammunition depots, hangars, military ports, caverns, military and civil airports, tunnels, military exercise bases, large electric power, chemical, coal mine, subway dangerous wharves
The characteristics of the new type of ocean power cable are as follows: the cable core is composed of insulated cable core and waterproof filling rope twisted together; An inner sheath layer, an armoring layer and an outer sheath layer made of polyolefin are successively arranged on the outer core of the cable from inside to outside. With high softness and according to the characteristics of sea salt fog, strong light, wind and rain, easy to mildew. The above environmental factors are fully considered in the selection of cable raw materials. The cable has the environmental requirements of anti-salt spray, anti-ultraviolet light, anti-seawater and anti-mildew under the condition of meeting its own requirements. It is suitable for military power distribution network or industrial facilities in Marine environment. Its remarkable technical characteristics are high mechanical strength, oil resistance, mud resistance, uv resistance, bunching flame retardant/fire prevention, high temperature resistance, low temperature resistance, etc. The cable adopts the structure design of power core, communication and data transmission cable integrated.