Francis turbine, kaplan turbine, pelton turbine, turgo turbine, bulb turbine, gate valve, butterfly valve, ball valve, synchro generator, excitation system, electric and control system.
No
The Axial turbine is for low head power plants. Water flows axially into and out of the turbine. Axial flow turbines fall into two categories, fixed blade runner and variable pitch runner, also known as a Kaplan turbine. Fixed blade turbines are very well suited to low head power plants with limited variation in head and load. Its main advantage is its simple design. When operated at fixed speed, maximum efficiency is achieved at the design head and water flow. Kaplan turbines are used for medium to large power stations where there are large variations in the head, water flow and load. Its main advantage is its ability to adapt to variable conditions with a high efficiency. The variable pitch runner is mechanically more complex than a fixed pitch runner. Axial flow turbines can be supplied for a head of 2m to 70 m. The runner diameter is available from 0.6 m to 5 m. Power capacity is from 55 kW to 50 MW.
In a Francis turbine, the water flows radially into the turbine and axially out of the runner. The Francis turbine, invented by an American engineer in 1849, is the most widely deployed modern turbine. The main characteristics of the Francis turbine are - a wide range of water head, simple and reliable structure, and high efficiency. A Francis Turbine can be supplied for a head of 15 m to 250 m. The runner diameter is available from 0.4 m to 4.5 m. Power capacity is from 75 kW to 50 MW. New style francis turbine, compared to the old one, it has the advantages of convenient installation, high efficiency, low noise and compact structure.
The tubular turbine is an axial flow turbine, in a straight or S-shaped configuration. A Tubular Turbine can be supplied for a head of 2 m to 30 m. The runner diameter is available from 0.8 m to 5.6 m. Power capacity is from 250 kW to 15 MW. This turbine has high efficiency and lower constructon cost.
Pelton turbine The runner has bucket shaped blades on the periphery. The jet of water is tangential to the runner. The characteristics are, high head applications, a simple design, few problems with cavitation, highly cost effective. Pelton turbines can be supplied for a head of 100m to 500 m. The runner diameter is available from 0.55 m to 1.5 m. Power capacity is from 200 kW to 10 MW. Inclined jet turbine: The water flows into and out of the runner at an angle to the main shaft. The characteristics are high efficiency over a wide range of water flow, more flexible installation options, somewhat more complex than a Pelton turbine. Inclined jet turbines can be supplied for a head of 60m to 300 m. The runner diameter is available from 0.32 m to 0.8 m. Power capacity is from 55 kW to 6.3 MW.
Runner diameters: 0.6-3m Suitable water head: h=3-30m Capacity of the generator unit: 160-20000kw The speed range of the turbine: 60-750rpm * the propeller type is with a vertical axle and fixed runner, blade angle can not be changed during operation mode, the efficiency curve is steep and this type is generally suitable for power station that has water head with slight change or its operating units can be adjusted according to actual load change. * the kaplan type is with adjustable runner controlled by oil servomotor and moved according to the load/head change to ensure higher average efficiency, the efficiency of some kaplan turbine is higher than 94%.
Supplier: Hydro turbine, water turbine, francis turbine, kaplan turbine, s type turbine, pit turbine, pelton turbine, incline turbine, turgo turbine, cross flow turbine, bulb bype turbine, horizontal turbine, vertical turbine
Francis turbine Francis turbines are built in a compact structure, with high efficiency, and can be applied to a wide range of water heads. This feature makes the Francis turbine type a widely used one around the world. The key Francis turbine components includes Runner, Distributor, Main shaft, Main shaft seal, Turbine guide bearing, Governor, among other. Application Scope: Application: Francis Water Turbine Generator Unit Water head: 20 ~ 700m Output: 0.01 ~ 1000MW Frequency: 50/60HZ Runner diameter 0.5 ~ 10m Life Span 30-50 years Getai Hydropower is a China supplier of Francis Turbine, Francis Turbine Generator, Francis Turbine Parts, Francis Runner, Construction And Working Of Francis Turbine. We have a complete quality management system. Choose us, you can be get most careful and thoughtful service! Pelton Turbine Design, Francis Turbine Design, Kaplan Turbine Design company China. Product Introduction 1. Advanced CFD, FEA technic is utilized in the designing process to ensure better technical solution. 2. CAE casting simulation is adopted for the produciton of casting parts, this advanced and reliable process plan could help effectively improve product quality. 3. All raw material strictly conform to international standard, key component such as runners, guide vane is Forged and entire CNC machined. Material No. C Si Mn P S Cr Ni Mo ASTM A473 S41500 â?¤0.05 â?¤0.60 0.5-1.0 â?¤0.030 â?¤0.030 11.5-14.0 3.5-5.5 0.40-0.80 ASTM A743 CA6NM â?¤0.06 Max1.0 Max1.0 â?¤0.040 â?¤0.030 11.5-14.0 3.5-4.5 0.40-1.0  Mechanical Property for ASTM A473 S41500 and ASTM A743 CA6NM Material No. Ï?0.2(Mpa) Ï?b(Mpa) δ5(%) Ï?(%) Akv (J/cm2) HB ASTM A473 S41500 â?¥620 â?¥795 â?¥15 â?¥45 â?¥50 â?¤295 ASTM A743 CA6NM â?¥550 â?¥755 â?¥15 â?¥35 â?¥50 â?¤285 4. State of the art machining and testing equipment, as well as licensed professional engineers all combined to help guarantee better product precisioness. 5. All product is subject to strict inspection according to international standards and client special requirements 6. With the help of 3D Assembling, through motion simulation, the entire organization interaction can be seen at a glance. This helped a great deal for parts processing and pre-installation. Pelton Turbine Rehabilitation, Kaplan Turbine Rehabilitation, Francis Turbine Rehabilitation China.
Kaplan & Tubular Turbine Kaplan Turbine is suitable for medium & low water head and large flow power plants. With same water head, the Kaplan runner speed is higher than that of the Francis'. The Kaplan runner blade can be either fixed and rotatory. The key components include: Kaplan runner, Distributor, Main shaft, Main shaft seal, Turbine guide bearing, Governor, Draft tube, Spiral case. Tubular Turbines are suitable to lower water head, is a kind of horizontal turbine with straight flow channel. There is no spiral case in Tubular turbine, and its blades can be fixed or rotatory. The key components include: Tubular runner, Distributor, Turbine guide bearing, Governor among other. Our Kaplan &Tubular Turbine has the features with Kaplan Turbine Design, Kaplan Turbine Advantages. Best quality and factory price will give you Application scope: Kaplan turbine Tubular Turbine Water Head: 3 ~ 80m 2 ~ 25m Output: 0.1 ~ 200MW 0.05 ~ 57MW Frequency: 50/60HZ 50/60HZ Runner Dia.: 1 ~ 11m 1 ~ 7m We also provide Casting Pelton Runner, Forged Pelton Runner, Casting Guide Vane, Francis Runner Band Heat Treatment, Pelton Turbine. Product Introduction 1. Advanced CFD, FEA technic is utilized in the designing process to ensure better technical solution 2 Â CAE casting simulation is adopted for the produciton of casting parts, this advanced and reliable process plan could help effectively improve product quality.
Kaplan Turbine is suitable for medium & low water head and large flow power plants. With same water head, the Kaplan runner speed is higher than that of the Francis'. The Kaplan runner blade can be either fixed and rotatory. The key components include: Kaplan runner, Distributor, Main shaft, Main shaft seal, Turbine guide bearing, Governor, Draft tube, Spiral case. Tubular Turbines are suitable to lower water head, is a kind of horizontal turbine with straight flow channel. There is no spiral case in Tubular turbine, and its blades can be fixed or rotatory. The key components include: Tubular runner, Distributor, Turbine guide bearing, Governor among other. Our Kaplan &Tubular Turbine has the features with Kaplan Turbine Design, Kaplan Turbine Advantages. Best quality and factory price will give you Application scope: Kaplan turbine Tubular Turbine Water Head: 3 ~ 80m 2 ~ 25m Output: 0.1 ~ 200MW 0.05 ~ 57MW Frequency: 50/60HZ 50/60HZ Runner Dia.: 1 ~ 11m 1 ~ 7m We also provide Casting Pelton Runner, Forged Pelton Runner, Casting Guide Vane, Francis Runner Band Heat Treatment, Pelton Turbine. Product Introduction 1. Advanced CFD, FEA technic is utilized in the designing process to ensure better technical solution 2. CAE casting simulation is adopted for the produciton of casting parts, this advanced and reliable process plan could help effectively improve product quality. 3. All raw material strictly conform to international standard, such as ASTM, IEC,ISO etc. key component such as runners, guide vane is Forged and entire CNC machined. Chemical Composition for ASTM A473 S41500 and ASTM A743 CA6NM% Material No. C Si Mn P S Cr Ni Mo ASTM A473 S41500 0.05 0.60 0.5-1.0 0.030 0.030 11.5-14.0 3.5-5.5 0.40-0.80 ASTM A743 CA6NM 0.06 Max1.0 Max1.0 0.040 0.030 11.5-14.0 3.5-4.5 0.40-1.0 Mechanical Property for ASTM A473 S41500 and ASTM A743 CA6NM Material No. ?0.2(Mpa) (Mpa) �5(%) ?(%) Akv (J/cm2) HB ASTM A473 S41500 620 795 15 45 50 295 ASTM A743 CA6NM 550 755 15 35 50 285 6.With the help of 3D Assembling, through motion simulation, the entire organization interaction can be seen at a glance. This helped a great deal for parts processing and pre-installation. 7.Each project will strictly follow manufacturying plan to ensure the delivery date. 8.ISO 9001 Quality Management system is carried out to ensure better management control Buy low price, high quality Hydraulic Turbine Generator, Hydro Turbine Runner, Water Turbine Hydro Power, 100kw Hydro Turbines, choose our productsGetai Hydropower is the leading factory & Company, Warmly welcome new and old customers to visit and patronize!