1. Model: AK-200FC/P
2. Gas detected: Gas, LPG, H2
3. Size115mm*71mm*43.3mm
4. Working voltage 220VAC /110VACíó12VDC-20VDC
5. Additional Function: electromagnetic valve
6. Patent NO.: 200830104028.5
7.Specific characteristics
(1) Our alarms have been solved the phenomenon of sensor drift which can prevent the alarms from false alarm or omission.
(2) Automatic diagnosis, error warning and prompt functions
(3) Working temperature0íp-60íp.
Gas alarm 220v powered gas leakage alarm Features: -hot wire type sensor -easy installation and maintenance -modernized design -detect all sorts of combustible gases, lpg and lng include City gas -ideal for all kitchens -excellent reliability & high stability -self test function -durable sensor head -less affected by other organic solvent -high accuracy -ac ~ dc adaptor included -loud sound signal of 85 db at alarm mode -three-year limited warranty. -suitable for the safety valve. Size:110mmx69x36mm Weight:270g/pcs Package size:43mmx110mmx142mm Quantity/box:110pcs
1. Model: AK-200FC/P 2. Gas detected: Gas, LPG, H2 3. Working voltage: 220 VAC /110 VACíó12VDC-20VDC 4. Additional Function:shut off valve 5. Networking: wired networking, wireless networking 6. Patent NO.: 200830104029.X 7. Specific characteristic: (1) long service life (2) Our alarms have been solved the phenomenon of sensor drift which can prevent the alarms from false alarm or omission. (3) Automatic diagnosis, error warning and prompt functions.
1. Model: AK-200FC/H2 2. Gas detected: Gas, LPG, H2 3. Size: 86mm*86mm*60mm 4. Working voltageú¦ 220 VAC /110 VACíó12VDC-20VDC 5. Additional Function: shut-off valve 6. Networkingú¦wired networkingú¿NOíóNCú¬ 7. Patent NO.: 200830103202.4 8. Wireless networking modeú¦315MHZ/433MHZ (2262 OR 1527) 9. Specific characteristic: (1) long service life (2) Our alarms have been solved the phenomenon of sensor drift which can prevent the alarms from false alarm or omission. (3) Automatic diagnosis, error warning and prompt functions.
BWR-01A is a fuel gas detector with high stability, used for checking the leakage of fuel gas and increase the safety. It adopts advanced catalytic gas sensor with high stability and sensitivity features. The detector supports microprocessor technology, it can trigger light and sound alarm, and remotely send related gas density value to alarm host by RF. It is suitable for areas where gas leakage may easily occurs. The gas detector can be used standalone, also can work as accessory in smart home application to realize remote alarm. 1.Audible & Visual Alarm; 2.Wireless communication with Alarm Host; 3.Anti High-frequency interference; 4.Automatic Fault Detection Indication; 5.Rolling code for anti-crack; 6.High Reliable Catalytic Gas Sensor.
Model: AK-200FC/C2 Sensors: Electrochemical Inspection gas: Carbon monoxide Working volt: AC220V/AC110V DC12V-DC20V(backup batteries 3 AA alkaline batteries or Rechargeable battery pack) Assorted function: Synchronous fans Wireless net:315MHZ(2262or1527). Patent NO:200830103203.9 1, Working temperature: -40degree~80 degree 2, Alarm density: Density(PPM) 50 100 300 400 Reaction time ( minutes) 60-9010-40Less than 3immediately 3, Interconnecting 1, circuit for normally closed relay contacts 2, circuit for normally open relay contacts 3, Operating Frequency: 433 MHZ/315MHZ (optional). 4, Size: 163mm*87mm*40mm 5, Weight: 400g/pcs 6, Package size: 65cm*46cm*39cm 7, Quantity/BOX: 100pcs 8, Weight/carton : 45kg. .
1. Model: AK-200FC/C4 2. Electrochemistry type sensorú¿Japanú¬ 3. Gas detected: carbon monoxide 4. Sizeú¦100mm*35mm 5. Working voltageú¦AC220/AC110íó12VDC-20VDC 6. Additional Function: linked fans 7. Networkingú¦wired networkingú¿NOíóNCú¬ 8. Wireless networking modeú¦315MHZ/433MHZ (2262 OR 1527) 9. Patent number: 200830104026.6.
Main features: Auto reset after alarm Mcu process Sensor with high stability Auto check and indication for malfunction Detecting natural gas and lpg Smt adopted Supports exhaust fan Technology parameter: Operating voltage: ac 220v or dc 9-16v Standby current: less than 90ma or less than 30ma (low power consumption) Alarm current: less than 100ma or less than 40ma (low power consumption) Rated power: less than 3w (ac 220v) Operating temp.: -10 to +50 degrees Working humidity: less than 95%rh Alarm mode: network output / sound & flash alarm / rf Alarm volume: more than 85db/m Alarm density: 10%lel Alarm output: relay output (n.C.And n.O. Optional) / rf signal Dimension: 70l*40w*110hmm Colour box or carton packing
Basic features Mcu processing High stability sensor Ceiling mounted Independent & network option Direct current 12v Auto reset after alarm Technical parameter Detecting gas:town gas.Co Working voltage:12v dc Standby current:ín120ma Alarm current:ín60ma Alarm density:50í½300ppm Buzzer:í²70db(1m) Operating condition:-10íµí½+55íµ; relative humidityín90%rh Stability:regular alarm density erroría80ppm Repeatability:repeative alarm density erroría80ppm Alarm density error:ía80ppm Alarm mode:sound&flash alarm/network alarm signal Size:ª¦115íß51mm Packing:80pcs/ctn gw:16.6kgs d:515*335*520