CE Approved Drug of Abuse Test is a qualitative immunoassay for detection of specific drugs present in human urine or saliva at the cutoff concentration of the drug specified. The drug test kit is available in strip, panel, cassette and cup format. Indications for Use (DOA) Drug of Abuse Test are for the detection of drug like COC AMP MOP TH MET OPI BAR BZO MTD MDMA TCA OX BUPPCP EDDP. Application Public security departments and anti-drug agencies to screen suspicious groups; Conscription and admission physical examination; Drug rehabilitation machine purchase treatment monitoring; General survey, screening and physical examination of medical, health and epidemic prevention departments. Format: strip, panel, cassette and cup Storage: store between 2â?? and 30 â?? Shelf life: 2 years Advantages Accurate results: according to international drug abuse monitoring standards; Good specificity: select monoclonal antibody with high specificity to minimize possible crossover; Easy to operate: do not need any equipment and additional testing; Samples are easy to collect and can be tested on site; Fast detection: 5 minutes to interpret the results, saving time; Joint testing: multiple drugs can be screened at once.
General Information Items : MOR/MET/THC/AMP/MDMA/MTD/COC/TCA/BAR/BZO, up to 15 kinds of Drug Tests Format: Strip, Cassette, Cup,and Panel Specimen: Urine Packaging Details: Pouch+Box+Carton packaging (1) With our companyâ??s Logo (2) With the natural package (3) With OEM package (4) ODM Anna Lee Int'l Market Executive SPANBIO T
The Oral Fluid Drug Screen Device for AMP/BAR/BUP/BZO/COC/COT/PCP/KET/MET/MOR/MTD/OXY/EDDP/PPX/THCparent/THC and metabolites is a rapid,oral fluid screeningtestthatcanbe performed without the use of an instrument. The test utilizes monoclonal antibodies to selectively detect elevated levels of specific drugs in human oral fluid. 25 devices/box.
Our product is based on the theory of enzyme interaction. It is used to detect the content of FSH atom in urine speciment. The colour change could identify the result directly. Assisting with the result, doctor could judget whether the patient is pregnant or not. 2.5mm, 200 strips/pouch, 10,000strip /case ,27kg 3.0mm, 50 kits/ pouch, 2,000 kits/case, 27kg 4.0mm, 150 cards/pouch, 2,500 cards/case, 25kg 5.0mm 10000strips/case 2000kits/case 2500cards/case.
Rapid diagnostic test kits
Cheap Drug Metabolites Rapid Test Accu-Tell® Multi-line Drug Cassette (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in urine at the cut-off concentrations. TEST PROCEDURE of Saliva Rapid Test Cassette Allow the test, urine specimen, and/or controls to reach room temperature (15-30 ºC) prior to testing. 1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour. 2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120 �¼L) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below. 3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.  LIMITATIONS 1. ACCU-TELL ®  Multi-line Drug Cassette (Urine) provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. 2. There is a possibility that technical or procedural errors, as well as interfering substances in the urine specimen may cause erroneous results. 3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen. 4. A positive result does not indicate level or intoxication, administration route or concentration in urine. 5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test. 6. This test does not distinguish between drugs of abuse and certain medications. 7. A positive test result may be obtained from certain foods or food supplements.  We are Saliva Test Manufacturer. Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.
Alcohol Urine Rapid Test Strip Accu-Tell® Alcohol Rapid Test Strip (Urine) is intended for use as a rapid method to detect the presence of alcohol in urine greater than 0.04%(40mg/dL). To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used. CATALOG Product Name Specimen Catalog No. Quantity per box Alcohol Strip Urine ABT-ACH-A188 100T/50T KEY POINTS Detection for:  Ehyl alcohol in human urine greater than 0.04%(40mg/dL); Reading time:  3 minutes; Relative Sensitivity:  96%; Relative Specificity:  100%; Agreement:  98%.  INTRODUCTION of Hot Sale Urine Rapid Test Strip Alcohol intoxication can lead to loss of alertness, coma, death and as well as birth defects. The BAC at which a person becomes impaired is variable. The United States Department of Transportation (DOT) has established a BAC of 0.02%(20mg/dL) as the cut-off level at which an individual is considered positive for the presence of alcohol. Determination of ethyl alcohol in urine, blood and saliva is commonly used for measuring legal impairment, alcohol poisoning, etc. Gas chromatography techniques and enzymatic methods are commercially available for the determination of ethyl alcohol in human fluids. ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is designed to detect ethyl alcohol in urine specimens.  INTENDED USE ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is intended for use as a rapid method to detect the presence of alcohol in urine greater than 0.04%(40mg/dL). The ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is intended for the detection of ethyl alcohol in human urine. To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used.  TEST PROCEDURE 1. Open the pouch package and remove the test strip. 2. Dipping the strip into the urine specimen for at least 20 seconds. 3. After wetting the reaction pad by urine specimen, immediately remove the strip from the urine specimen. 4. Read the alcohol test results at 3 minutes. Compare the color of the reaction pad with the color card to determine the relative urine alcohol level.