Carbon Steel Pilot Operated Pressure Reducing Valve Rating : Max. Inlet Pressure 350 PSIG (24.1 Bar) Set Pressure range 5/60, 20/50, 40/125 PSIG for Steam Material : Carbon Steel Description : Pilot Operated, R-Type Trim : SS410 + Stellite Ends : Flanged Specials : IBR Item Code : BM000030 Size : 15mm Notes : Available Valve Size : 25mm to 200mm
pilot solenoid valve 300AA00126A As a comprehensive enterprise integrating R&D, manufacturing and sales, YOYIK always adheres to the "customer-centric" business philosophy and is committed to providing one-stop equipment procurement and technical services. The company has an experienced technical team and a complete after-sales service system, which can quickly solve various problems of customers in the process of equipment installation, commissioning and maintenance, and ensure the smooth progress of customer projects. Whether it is large-scale power station construction or small-scale equipment transformation, YOYIK is a trustworthy partner. The following are the series of components we can provide for power plants: #DF-pilot solenoid valve 300AA00126A-DF Differential pressure balancing valve 32MKW01AA171 Pneumatic transmission device VTI06S10-NH2BWHO Oil throwing ring DG600-240-04-03 Bearing components 2335 butterfly valve 80D0F4PB3 Inlet end cover HPT300-340-04-02 Bottom valve group of steel cylinder NXQ-A-16/10.0-F Condensate water make-up pump SDH80-65-160A Reduction gearbox MO2225.OBM0C1D1.5A hand valve Z41H-10C mannual bellows globe valve KHWJ25F-1.6P oil pump PVH098B01AJ30A250000001001AB010 Trip Lock Valve CN70093-01 oxygen Pressure relief valve YQJ-11A Plug valve SD61H-P35 50C Guide vane bushing PCS1002002380010-01/541.01 Valve V38577 types of servo valve D631-271C Combination washer JB982-77 globe shut off valve J41H-16C D100 solenoid valve DG4V-3-2C-VM-U-H7-60 car oil unloading pump 2CY-60/0.55 solenoid valve SV25-212D hydraulic servo valve working principle D682-4241 AST solenoid valve 3D01A011 The electromagnetic valve 3D01A006 pressure relief valve YSF9-35/50-TA high temperature globe valve 40FJ-1.6PA2 seal ring HB4-56J8-19 coupling 0250/0011 Self-locking flow regulating valve TS40W-16P 1.6MPA, DN80 Solenoid Valve SV310F3C0 solenoid valve HQ16.16Z O-shaped sealing ring HQ01.129 OIL PUMP SQP32-38-14VQ-86-DD-18 O-ring HY-SO-0034 pilot solenoid valve 300AA00126A pilot solenoid valve 300AA00126A MY-DFYL-2024-8-1
Erik compared more than 20 hydraulic pilot pressure control valve factories. No manufacturer can do the hydraulic pilot operated pressure control valves which can be used under high pressure above 450bar for more than one year. AAK hydraulic pilot operated pressure control valve passes the test at one time, and there is no abnormality after one year of use. Erik is from a German hydraulic equipment manufacturer. In the first half of last year, the company needed to purchase a special hydraulic pilot operated pressure control valve with a working pressure of more than 450 bar, a service life of more than one year and a durability of more than 2 million times. The boss realized that it was some difficult to purchase the hydraulic pilot operated pressure control valve this time, and asked Erik and his colleague to purchase at the same time. Whoever successfully purchased the hydraulic pilot operated pressure control valve first will be promoted and raised. Erik is full of energy and keeps looking for hydraulic pilot operated pressure control valve factories online and offline. He contacted more than 20 new suppliers, including AAK hydraulic valve. Most of the hydraulic pilot operated pressure control valve manufacturers replied that they need to be customized from the beginning of materials, and it takes 25 days to sample this special hydraulic pilot operated pressure control valve. Erik chose two factories to test the samples. A month later, Erik received the samples and asked the engineer to test them. The results failed, but the hydraulic pilot operated pressure control valve obtained by his colleague passed the first test, which made Erik very depressed. Fortunately, this is just in the test stage, the final effect depends on the test results of the hydraulic pilot operated pressure control valve one year later. Erik contacted AAK for the second time. He clearly informed that the samples of hydraulic pilot operated pressure control valves he selected in the first round failed. For the first time, he did not choose AAK because AAK needed 35 days. This time, he only asked AAK to make samples. Whether he can win or not, he can only count on AAK. Because the material selection and internal test of hydraulic pilot operated pressure control valves need time, Erik also understands the difficulties of making the samples. After 35 days, AAK sent 6 samples of hydraulic pilot operated pressure control valves. Last week, almost a year after the hydraulic pilot operated pressure control valve samples were sent, Erik sent an email to inform that AAK hydraulic pilot operated pressure control valve was the only sample that passed 2 million tests, and there was no abnormality after one year of use. Although his colleague's sample passed the early test, it could not withstand the high pressure above 450 bar for enough time, it leaked in less than a year.
On Monday afternoon, I received an email from Tony. Tony is a purchasing manager of CASAPPA in Italian, mainly responsible for the purchasing of hydraulic pump components, and the work has been very smooth. Last month, they received a complaint from the largest customer that the pressure at the outlet of the hydraulic pump sometimes rises by itself, resulting in unstable operation of the equipment. The customer's site engineer couldn't solve it and turned to CASAPPA for after-sales service. Although the warranty period has expired, they still need to help customer solve the problem. Their engineers tested various parameters of the hydraulic pump. After comprehensive analysis, they were still uncertain about the root cause, but they suspected that the hydraulic pressure relief valve in the pump is faulty. The engineer asked Tony to contact the original supplier of the hydraulic pressure relief valve and ask him to send a sample of the hydraulic pressure relief valve for replacement and test. It is a local hydraulic valve manufacturer and they still have samples in stock. After receiving samples and commissioning, the engineer's suspicion was proved to be correct. After replacing the hydraulic pressure relief valve, the hydraulic pump worked normally. Tony asked the original hydraulic valve manufacturer to urgently replenish 30 hydraulic pressure relief valves to solve this complaint. The manufacturer said that the shipment has passed the two-year warranty period. At present, there are only 3 samples in stock. The remaining quantity needs to wait in production schedule for production, and can only be delivered after 3 months. If offering this plan to the big customer, Tony would be scolded by the boss. He thought of AAK, because the hydraulic valve failed last year, which was also solved by AAK. Tony established a business relationship with us last October. Now we are also friends besides business. We often discuss the knowledge related to hydraulic valves. His email on Monday is just to ask for help on this hydraulic pressure relief valve. After knowing these conditions, I asked him to send us samples of those faulty hydraulic pressure relief valves, and provide us the drawings of this hydraulic pressure relief valve, noting those special requirements. After receiving and disassembling the samples from Tony, we found that the main valve spool of the hydraulic pressure relief valve was too loose and had increased leakage, then the pressure at the oil outlet increased. The problem should be caused by high-frequency wear or insufficient accuracy of the original shipped hydraulic pressure relief valve. The engineer of CASAPPA asked us to reply why it was determined that it was the problem of the valve spool?
On Monday afternoon, I received an email from Tony. Tony is a purchasing manager of CASAPPA in Italian, mainly responsible for the purchasing of hydraulic pump components, and the work has been very smooth. Last month, they received a complaint from the largest customer that the pressure at the outlet of the hydraulic pump sometimes rises by itself, resulting in unstable operation of the equipment. The customer's site engineer couldn't solve it and turned to CASAPPA for after-sales service. Although the warranty period has expired, they still need to help customer solve the problem. Their engineers tested various parameters of the hydraulic pump. After comprehensive analysis, they were still uncertain about the root cause, but they suspected that the hydraulic pressure relief valve in the pump is faulty. The engineer asked Tony to contact the original supplier of the hydraulic pressure relief valve and ask him to send a sample of the hydraulic pressure relief valve for replacement and test. It is a local hydraulic valve manufacturer and they still have samples in stock. After receiving samples and commissioning, the engineer's suspicion was proved to be correct. After replacing the hydraulic pressure relief valve, the hydraulic pump worked normally. Tony asked the original hydraulic valve manufacturer to urgently replenish 30 hydraulic pressure relief valves to solve this complaint. The manufacturer said that the shipment has passed the two-year warranty period. At present, there are only 3 samples in stock. The remaining quantity needs to wait in production schedule for production, and can only be delivered after 3 months. If offering this plan to the big customer, Tony would be scolded by the boss. He thought of AAK, because the hydraulic valve failed last year, which was also solved by AAK. Tony established a business relationship with us last October. Now we are also friends besides business. We often discuss the knowledge related to hydraulic valves. His email on Monday is just to ask for help on this hydraulic pressure relief valve. After knowing these conditions, I asked him to send us samples of those faulty hydraulic pressure relief valves, and provide us the drawings of this hydraulic pressure relief valve, noting those special requirements. After receiving and disassembling the samples from Tony, we found that the main valve spool of the hydraulic pressure relief valve was too loose and had increased leakage, then the pressure at the oil outlet increased. The problem should be caused by high-frequency wear or insufficient accuracy of the original shipped hydraulic pressure relief valve. The engineer of CASAPPA asked us to reply why it was determined that it was the problem of the valve spool?
In this year, , an customer, visited 5 hydraulic valve factories before and after, and made samples of hydraulic relief valve with 1m inner hole for 3 times, but none of them reached the accuracy requirements. sent samples and met the standard for the 1st time, finally chose to cooperate with . The inner hole accuracy is not enough, which is mainly caused by the different built in equipment of honing machines equipped by many hydraulic valve manufacturers. Conventional honing machines use diamond reamers., Because the main cutting part of the diamond reamer is at the tool head, the tool head wears quickly. After the head is worn, it is very easy to cause the size of the hole bottom to be small, resulting in the poor cylindricity of the whole hole and affecting the accuracy. This is the key to the 5% accuracy error. Many hydraulic valve manufacturers are not aware of this key point. , a purchaser from a hydraulic valve in , has an inquiry for a special hydraulic relief valve, and the inner hole accuracy must be controlled within 1m. checked with the original hydraulic valve supplier, and got reply that only the hydraulic valve manufacturer equipped with high precision honing machine is able to make the hydraulic relief valve with 1m inner hole accuracy. According to the equipment configuration, has contacted with more than 10 hydraulic valve manufacturers, determined to visit 5 hydraulic valve manufacturers, and asked 3 powerful factories to sample the hydraulic relief valve. After testing and comparing the samples received from these 3 hydraulic valve factories, all failed to meet the standard. asked the manufacturer with the highest accuracy to continue to improve the proofing, and there is still 0.1m gap. The factory gave up and introduced HYDRAULIC VALVE to him, maybe can do the hydraulic relief valve with 0.1m inner hole accuracy. According to his hydraulic relief valve drawing, we advised that we can send 1pc hydraulic relief valve quality sample after 10 days. 5 days after successfully sent the hydraulic relief valve sample, Bowen informed that the accuracy met the standard. He wanted to know why so many hydraulic valve manufacturers could not achieve 1m inner hole hydraulic relief valve, even if the hydraulic valve manufacturers promised to do so and they also have high precision honing machines, but several proofing did not meet the standard. How did hydraulic valve achieve it Honing machine is really helpful for the machining of high precision inner hole. Due to different equipment configuration, not every hydraulic valve manufacturer can produce the hydraulic relief valve with 1m inner hole accuracy.
For Hydraulic Piloted Directional Valve equivalent to HydraForce PD10-32, AAK received the re-peat order from our old customer in Turkey Last October, we shipped a hydraulic piloted directional valve equivalent to HydraForce PD10-32 to one of our old customers in Turkey. The PD10-32 is a screw-in, cartridge style, pilot operated, spool-type, normally closed, hydraulic directional valve. In Ningbo, there are only a few hydraulic cartridge valve manufacturers who have this model. AAK price is higher than the other hydraulic cartridge valve manufacturers in China. The competition is very fierce in the market in Turkey, but customer still placed the order with AAK, because as an old customer of us, he knows that AAK valve has stable performance and longer service life. It has been over 1 year since we shipped the trial order. Today, we received an email from the customer that he needs to place a mass production order for 500 pcs and wants to know the lead time. AAK hydraulic piloted directional valve 2 advantages: 1. The quality of this valve is benchmarking HydraForce, but price is much cheaper. 2. The service life is 2 times that of domestic hydraulic cartridge valve manufacturers in China Technical parameters of AAK E-PD10-32 Hydraulic Screw-in Cartridge Piloted Directional Valve: Operating Pressure: 240 bar (3500 psi) Flow Rating: 40 lpm (10 gpm) Internal oil leakage: 82 ml/min. (5 in�³/min.) at 240 bar (3500 psi). Pilot Pressure Required: To full Spool Shift 4.7 bar for 4.1 bar spring; 8.6 bar for 7.6 bar spring Temperature: - 30�°C ~ +100 �°C (with standard Buna N seals) Fuilds: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus) Cavity: VC10-3 AAK E-PD10-32 hydraulic screw-in cartridge piloted directional valve, benchmarking HydraForce PD10-32, you are welcome to try it out. AAK HYDRAULIC VALVES (828) 2024-12-18
Richard is a purchaser of ATOS company in Italy. Last September, ATOS received a complaint from a South African customer that the starting pressure of the hydraulic pump was often insufficient recently. The field engineer analyzed that the valve spool spring of the pilot hydraulic relief valve of the hydraulic pump was deformed, resulting in the unstable pressure of the hydraulic system. He tried to replace the pilot hydraulic relief valve to solve the problem. The customer questioned the stability of their equipment because it had been used for less than 1 year. After learning about it, the owner asked Richard to solve the customer complaint as soon as possible and replace this batch of pilot hydraulic relief valves. Richard wondered about the problem with the pilot hydraulic relief valve. This pilot hydraulic relief valve was produced by an American company and was re purchased this time. The original manufacturer replied that this pilot hydraulic relief valve has been produced according to the standard. The strength limit and elastic limit of the piano steel wire used meet the requirements. The problem should be caused by improper use by the user. Of course, he can not tell the owner of such results. The original manufacturer was unwilling to take responsibility. Richard contacted nearly 20 hydraulic valve manufacturers, including AAK hydraulic valve. After several rounds of communication, Richard eliminated half of the hydraulic valve manufacturers, and then asked the shortlisted hydraulic valve manufacturers to send their own ready-made pilot hydraulic relief valves. Their company conducted spring elasticity test. Finally, 5 manufacturers were selected to send samples for the second round according to the drawing size of his pilot hydraulic relief valve and improve the spring elasticity. After communicating with Richard, we learned that the service limit pressure of the hydraulic pump is above 350bar and the service frequency is very high. Although the piano wire spring used by Sun, the original American manufacturer, is advanced, special materials must be used for this special working condition. We started to test the special spring first. Richard has received samples of pilot hydraulic relief valves from other 4 factories, but AAK hasn't sent them yet. Richard pushed us several times and we advised that we are still in testing. Richard may think AAK should not be able to do it. AAK engineers spent 3 weeks, 6 times replacing materials and 9 times proofing, determined the special alloy steel spring as a trial, and sent the pilot hydraulic relief valve 30 days later. We specially asked Richard about the test of the pilot hydraulic relief valves from the other 4 manufacturers. Richard advised that if AAK pilot hydraulic relief valve could not pass the test, he would need a new round of looking for suppliers.
mainly responsible for the purchasing of hydraulic pump components. Last October, developed a new hydraulic pump and planned to promote this new product at this year's exhibition. During the debugging, the output pressure of the hydraulic pump can not be established several times, which is a little troublesome, because the owner has sent all the invitations to the exhibition to the customers and grandly introduced the functions of this hydraulic pump. The R & D personnel checked and tested each component one by one. It is basically certain that it is caused by the instability of the pilot operated pressure control valve. The technical team dissected the pilot pressure control valve and found local friction marks on one side of the hole wall of the valve body. The diagnosis conclusion is that the main valve spool is stuck, which should be caused by the concentricity difference between the hole of the main valve body and the hole of the pilot pressure control valve body. to re purchase the pilot pressure control valve that meets the technical requirements, which must be solved within 25 days, otherwise he will leave because the exhibition is too important. the original hydraulic valve manufacturer and got a reply that due to equipment, he could not produce high-precision pilot pressure control valves with the exactly same concentricity. At the same time, he contacted a number of hydraulic valve suppliers and they basically replied that they could not do such a high precision pilot operated pressure control valve, which made almost . When searched the hydraulic valve suppliers in , he found AAK HYDRAULIC VALVE. The details page of the hydraulic valve on AAK made feel that maybe AAK could have a try. He emailed us firstly to ask whether the concentricity of the pilot operated pressure control valve could be consistent. We need the detailed drawings, working conditions and parameters of his whole hydraulic pump to judge. After receiving all information from him, AAK technical team pondered the whole afternoon, with more than 95 confidence, and it would take 15 20 days to complete it. he was happy and uneasy. He was happy that some hydraulic valve manufacturer could try this high-precision pilot operated pressure control valve and has a high probability of success. He was uneasy that if AAK HYDRAULIC VALVE did not succeed in proofing, the time would be wasted. We understand his concern. We told him that the reason why we are not sure for 100 is that there is a data that can't be determined. If AAK HYDRAULIC VALVE failed in sampling, then he should not waste time in Ningbo area. We suggest that he also find a hydraulic valve supplier in Europe, so as to sample with AAK at the same time.