Pressure transmitter CY-I for Ennore power
Since its establishment, YOYIK has always adhered to the principle of technology first and quality first. It has a team of senior engineers and technical workers in the industry. They integrate their rich experience in power station construction into product design and manufacturing to ensure efficiency and accuracy in every link. The company provides a full chain of services from equipment selection to after-sales maintenance, guided by customer needs, continuously optimizes solutions, and promotes the development of the energy industry.
Yoyik can offer many spare parts for power plants as below:
#DF-Pressure transmitter CY-I for Ennore power-DF
Eddy Current Sensor PR6423/004-111
variable displacement transducer DET-25A
Circulating Water Travel Switch 1M12-02BOS-ZW1
LVDT of CV TDZ-1-H 0-250
LVDT Sensor HDC3-250-01-01-10
Voltage Meter HCD194U-9D1
Weighing controller MW96C
Level switch RC860MZ097Z
k type digital thermometer TE-212
HMI 6AV6647-0AE11-3AX0
Level Switch 397001-N33519
Axial displacement card DF2002
Level Transmitter 5301HA2H1N3AM00145BANA M1
Gap digital display meter MB3204
Differential pressure switch BDSN4KB25XFSHX
Electric Actuator RAIII 14AF1 4B4
Temperature switch T768TS040XCNC4 20/95C
Heat Exapansion Sensor TD-2
Auxiliary Contacts LXW22-11MB
Flow Switch LKB-01B
Ethernet Switch MOXA
Integrated temperature transmitter WRNKB-446S/TG
Cards DZXL-ZL-E-725
pt100 probe 2 wire WZPK2-380B
Bolt electric heating rod ZJ-20-16A
NEPM meter Ampere
Yellow light XB2-EV445
LVDT Sensor HL-6-150-6
EH OIL PRESSURE HIGH CMS-Z
Thermostat Pinhole Lens YF-A18-5A-2-15
Travel switch L*19-001
Yellow light XB2-EV445
MAGNETIC SWITCH 12 - 24 VDC
magnetic linear position sensor DET200
Intermediate relay UEG/A-2H/110VAC
Acoustic conduit DZXL-IIB1
Pressure transmitter CY-I for Ennore power
MY-DFYL-2024-11-6
I posted below a load of LCD Monitors that is currently available and looking for best offers only. The load is packaged in 40 gaylord boxes and will fill a 40' HC container. I attached our grading chart which details each grade in this load with associated pictures. I also attached pictures of this stock for your easy reference. LCD stands will be included with the load, but since they are removed we cannot guarantee all stands match the LCD monitors in this load. Grade A LCD Monitors 19" Widescreen 730 units 22 Widescreen 528 units 24 Widescreen 148 units Grade B LCD Monitors 19 Widescreen 546 units 22 Widescreen 558 units 24 Widescreen 116 units Total Quantity: 2,626 units
Divanti Group is a large processor of used LCD/ LED Monitor panels. Our current monthly production is 35,000 panels. Our LCD/LED Panels have been thoroughly tested to ensure they are able to be reused or remanufactured. After our testing process, we sort and package by size of the screen (15", 17", 19"-21" Regular, 19"-21" Widescreen & 22" and Larger Widescreen). Our packaging department is able to package the panels in bulk boxes or for additional charges we can use custom packaging if required. We typically sell our loads as mixed size panels, but we are also capable of selling custom loads with select sizes and quantities as inventory becomes available. I attached some sample pictures as our LCD panels were tested for your reference. Feel free to contact us for more information regarding our LCD products. Thank you, Scott
Supplier: Solar products, solar appliances, home appliances, electric appliances, lithium battery, gel battery, hybrid inverter, solar lights, solar accessories, solar fan, power inverter, electric cooker, led tv, solar power station
HR3210 Micro-power Pressure Transmitter overviews HR3210 series are lower power consumption pressure transmitter,which produced especially to measure liquid pressure in the field without power supply. It is stable, reliable, high precision and easy to assembly and disassemble. It uses well-known brands pressure sensor in the world and 1Cr18Ni9Ti stainless steel structure, intrinsic safety type circuit design. The biggest advantage of the transmitter is low power consumption , the operating current is lower than 900uA, so it is easy for dry battery to supply in the field. Quick response, the single-chip can be used to make the intermittent power supply pressure acquisition system. It can reach the balance within 400 uS when power on, obtain accurate data, and then turn off the power. It will turn on when collecting data. Features .Long time and reliable operating .Low power consumption, high accuracy .Protection by the isolated and stainless steel 316L diaphragm, anti-corrosion Specifications Range 0ï½?1ï¼?1.6,2,2.5ï¼?â?¦100Kpaï¼?MPa Over-load liquid level 1.5tims F.S accuracy ±0.25%FS, ±0.5%FS, ±1%FS (Non linearity, repeatability, hysteresis) Operating Temp. ï¼?15ï½?+60 Compatible medium Compatible with 1Cr18Ni9Ti and fluoro rubber Operating current < 900uA Output Signal 0.25ï½?2.25Vdcï¼?0.25-2.25Vdcï¼?0.5-4.5Vdc Voltage 3ï½?5Vdcï¼? Insulation > 100MΩ@500V Electrical connections Direct cable, housing protection IP65 Pressure interface M20Ã?1.5M; or customized Response time
Travel transmitter LTM-3A-I for Anpara power YOYIK, a Chinese brand that is also influential in the international market, has demonstrated the strength of "Made in China" by exporting high-quality power station equipment and accessories. The company's products are exported to Europe, America, Southeast Asia and other places, not only because of their excellent performance, but also because of the company's strict compliance with international standards and the international layout of the service system. YOYIK seeks development and shares results with global partners with an open attitude. Yoyik can offer many spare parts for power plants as below: #DF-Travel transmitter LTM-3A-I for Anpara power-DF Ammeter PA194I-9D4 De-excitation Switch 3BHS216233E20 LVDT transmitter XCBSQ-01/250-01-01 Pressure Switch 397289-SA6DT8 Fan LDC AFX-155023 H BFP Rotation Speed Probe CS-03 Limit switch WLCA12-TH High Voltage Fuse SDLAJ-7.2kV/ 31.5A -50kA, XRNTO-7.2 with striker Eddy current sensor DS821.ds1003/10/039/012/010/000/0 Bolt electric heating rod ZJ-20-18 Sensor DF310030-40-01-01-00 Excitation System Distributor FL-II 3000A/75mV variohm linear potentiometer TDZ-1G-31 Excitation Cabinet Fan D2E160-AB01 temperature probe TE-304 LVDT transmitter XCBSQ-02/600-02-00 High frequency switching power supply TTX-B1-A Guide Wave Radar Level Tansmitter HP30TDW4AA5000 Differential Pressure Transmitter 3051TG3A2B21AB4M5 rpm speedometer WZ-3C Differential pressure transducer RC861CZ090HY994 Sensor DF310806 LVDT transmitter XCBSQ-01/500-01-12 Liquid level alarm YKJD24-II-660-560-220 water tank level monitor UHZ-618C17 SENSOR DIFFERENTIAL EXPANTION PROBE PR6426/010-040 + CON 021/916-160 Eddy Current Sensor PR6422/102-101 Speed sensor CS-1G-D-085-02-01 Differential pressure transmitter CMS-0.35MPa speed sensor G-065-08-01 touchscreen 2711P-T6M20D8 Travel transmitter LTM-3A-I for Anpara power MY-DFYL-2024-10-29
ALTUS AL32L 4960 4B LED TV (32 inches)
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
General Description The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media. Technical Index Measuring medium: liquid, gas, steam Pressure range: -0.1MPA~0~60MPA Accuracy grade: ±0.2%FS, ±0.5%FS Stability: â?¤0.2%FS/year Temperature drift: â?¤0.02%FS/(range 0~70) Environment temperature: -20+85 Storage temperature: -20+85 Output signal: 4-20mA or 1-5VDC Supply voltage: 12-40VDC Allow overload: two times the quota voltage Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6 Wetware material: 316 stainless steel and 1Gr18Ni9Ti Shell material: die casting alloy aluminum,surface epoxy spraying Pressure interface: M20X1.5 Weight: ordinary 0.75kg, with on-site instructions 1kg Structure Type x1 Connection x2x31 x4 The link mode and output signal of the compact tranmitter are as follows: Two-wire system: 1 Positive power supply 2 Negative power supply 3 Empty 4 Shell Three wire system: 1 positive power supply 2 Negative power supply (Negative sharing with signals) 3 Signal+ 4 Shell x5 The connection mode of aviation plug transmitter is as follows: Two-wire system(direct outlet type) 1 Red wire connection positive power supply 2 Black wire connection negative power supply Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months.