Description
E6000 is a portable model with multiple gas detectors. It can continuously measure the concentrations of up to six combustible gases, oxygen, and toxic gases in the surrounding environment, and issue an alarm when the gas levels are abnormal.It adopts interchangeable smart sensor modules, easy to replace the sensors and maintenance.It is applicable to explosion-proof places: steelworks, petrochemical plant, oil industry, shipbuilding yard, sewage treatment plant, mine, power supply works etc.
Key Features
Interchangeable smart sensor module
Intrinsically safe
Built-in sampling pump (optional)
Visual, audible and vibration alarm
Adjustable alarm levels and span calibration values
Password management
Self-test after power on
Self-diagnostic and self-correction function
Real-time clock
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
Hard and tough quality Unbreakable
Overview The gas relay calibrator is a tester device that specializes in verification of gas gas relays. The gas relay calibrator is a detection check device for the detection of the Vaste Relay Flow Period Value, Cable Point Value, and Sealing Pressure Value. Gas Relay Calibrator is suitable for more than 90 of Gas Relay checks in Gas relay is also known as gas gas relay, is a protective unit in an oil immersion transformer, mounted in an oil pipe under transformer oil pillow. The gas relay detector is a dedicated gas relay pressure release valve calibrator device for the gas relay value, a capacity value, and sealing pressure value, and the gas relay tester uses a microcomputer control technology, and the gas relay tester is detected by detecting a high-precision pressure sensor. When the gas relay tester simulates the internal failure of the transformer, the gas method of the gas relay tester is calculated to calculate the flow rate value to achieve the detection of gas relatives, the Gas protection action value, the gas relay calibrator adopts the fine container combined with the US MCC's micro Press the precision sensor, detect the inside of the gas relay to exclude the liquid volume method to calculate the light gas capacity value Technical parameter Portable gas relay calibrator Protection IP65 Execution standard Compliance with DL T540-1994 standards and IEC power input 50HZ 220V Flow speed detection heavy gas 0. 0.5m s 0.05m s resolution 0.01 0.52.5m s 0.1m s resolution 0.1 Maximum error 1 Volume detection light mill 0 300ml resolution 0.01ml 300ml 700ml resolution 0.1ml Maximum error 1 test method Automatic measurement, semi automatic measurement, manual measurement of three measurement methods Sealing test 0-150KPA resolution 0.1 0-300KPA resolution 1.0 Comprehensive error
Product Introduction: The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio. The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range. Technical parameters: Power supply 3V DC 2 alkaline batteries Maximum sensitivity R12 R22 R134a approved (14g/year) Limiting sensitivity about 20 hours Probe life About 20 hours Operating temperature Battery life about 30 hours under normal use Working way continuous unlimited Response time instantaneous Reset time 1 SEC Warm-up time about 2 seconds Weight 560g
Product Introduction: The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio. The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range. Technical parameters: Power supply 3V DC 2 alkaline batteries Maximum sensitivity R12 R22 R134a approved (14g/year) Limiting sensitivity about 20 hours Probe life About 20 hours Operating temperature 0â??-52â?? Battery life about 30 hours under normal use Working way continuous unlimited Response time instantaneous Reset time 1 SEC Warm-up time about 2 seconds Weight 560g Size 229 65 65mm3 Probe length 35.5cm
Description: Ultra High Sensitivity SF6 Trace Gas Leak Detector-Q200 Sensor: Electron capture Leak Rate:1 x 10-8 ml/s 0.1ppm [With optional capillary inlet,1 x 10-10mL/s SF6] Response:1 sec (85% of reading) Concentration Sensitivity 0.01 ppm Recovery time 1sec Options Calibrated leaks Battery use time 20 Hours Display Alpha numeric VFD Manufacturing Standards To ISO 9001:2015 Certified,to CE requirements Service life:more than 20years
Parameter DR-600 Fixed gas detector Detection Gas Methane (CH4) Range 0-100%LEL Min Reading 1%LEL Display Error �±5%(F.S) Transmission Distance 1,200m Alarm Point Low Alarm:20%LEL High Alarm:50%LEL Rated Power 2.5W Output Signal 4-20ma/RS485 Detection Way Diffused Response Time â?¤60s Cable Specification Three wire system RVVP3*1.0mm2 Working Temp -10â??~55â?? Working Humidity 10~93%RH Storage Temp 10â??~35â?? Sensor Type Catalytic Combustion Power Supply DC24V Production Grade Exd IIC T6 Gb Protection Grade IP66 Electrical interface M20*1.5mm2 Alarm Way Sound alarm Sensor Life Clean air for 2 years Way to Install Fixed bracket/tube mounting/wall mounting Weight 1.75kg Size 210*190*95mm
Product Description: SR-902 Main Features: Auto reset after alarm MCU process Sensor with high stability and low power consumption Detecting natural gas and LPG SMT adopted Technical specification: Operating voltage: AC 220V or DC 9-16V Standby current: less than 90mA or less than 30mA (low power consumption) Alarm current: less than 100mA or less than 40mA (low power consumption) Rated power: less than 3W (AC 220V) Operating temp.: -10 to +50 degrees Working humidity: less than 95%RH Alarm mode: network output / sound & flash alarm / RF Alarm volume: more than 85dB/m Alarm density: 10%LEL Alarm output: relay output (N.C.and N.O. optional) / RF signal Dimension: 70L*40W*110Hmm
BX176 portable single gas detector can make continuous detection to combustible and toxic gases. It is suitable for combustible and toxic gas leakage detection in underground pipe or mines, and keeps the workers safe, prevents the facilities from being destroyed. Key Features 2000 detected records Two alarm level, adjustable Calibration point adjustable STEL alarm and TWA alarm for toxic gases Visual, audible, vibrating alarm Self protection against high concentration combustible gas Low battery alert Data uploading Password management Self-test when power on Self-diagnostic and self correction function